Bus-Powered M Series Multifunction DAQ For USB Ñ 16-Bit .

2y ago
18 Views
3 Downloads
238.85 KB
7 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Javier Atchley
Transcription

Bus-Powered M Series Multifunction DAQ for USB —16-Bit, up to 400 kS/s, up to 32 Analog Inputs, IsolationNI USB-6210, NI USB-6211, NI USB-6212,NI USB-6215, NI USB-6216, NI USB-6218 Up to 32 analog inputs at 16 bits,up to 400 kS/s (250 kS/s scanning) Up to 2 analog outputs at 16 bits Up to 32 TTL/CMOS digital I/O lines Two 32-bit, 80 MHz counter/timers Digital triggering NI-PGIA 2 and NI-MCalcalibration technology forimproved measurement accuracy NI signal streaming for 4 high-speeddata streams on USB Bus-powered Available with CAT I isolation 1-year warranty Additional warranty and calibrationservices availableRecommended Software LabVIEWLabVIEW SignalExpressLabWindows /CVIMeasurement StudioOther Compatible Software C#, Visual Basic .NET ANSI C/C Measurement ServicesSoftware (included) NI-DAQmx or NI-DAQmx Basedriver software Measurement & Automation Explorerconfiguration utility2 LabVIEW SignalExpress LE2Operating Systems Windows Vista (32- and 64-bit)/XP/2000 Mac OS X1 Linux w/68-pin SCSIScrewScrew/68-pin SCSIScrewAnalogInputs1616161616321MacOS X and Linux kits are not available for USB-6212 and USB-6216kits only2WindowsResolution(bits)161616161616Max Rate(S/s)250 kS/s250 kS/s400 kS/s250 kS/s400 kS/s250 kS/sAnalogOutputs022222Analog InputResolution (bits)161616161616Max Rate(S/s)250 k250 k250 k250 k250 k250 kRange(V) 10 10 10 10 10 10Digital I/O4 DI/4 DO4 DI/4 DO32 DIO14 DI/4 DO32 DIO18 DI/8 DO32-BitCounter222222Isolation–––60 V CAT I60 V CAT I60 V CAT I24 digital I/O for 68-pin SCSI mass terminal versions.Table 1. NI USB-621x Selection GuideOverview and ApplicationsWith recent bandwidth improvements and new innovations fromNational Instruments, USB has evolved into a core bus of choice formeasurement and automation applications. NI M Series devices for USBdeliver high-performance data acquisition in an easy-to-use and portableform factor through USB ports on laptop computers and other portablecomputing platforms. NI designed a new and innovative patent-pendingNI signal streaming technology that enables sustained bidirectionalhigh-speed data streams on USB. The new technology, combined withadvanced external synchronization and isolation, helps engineers andscientists achieve high-performance applications on USB.NI M Series bus-powered multifunction data acquisition (DAQ)devices for USB are optimized for superior accuracy in a small formfactor. They provide an onboard NI-PGIA 2 amplifier designed forfast settling times at high scanning rates, ensuring 16-bit accuracyeven when measuring all available channels at maximum speed.Downloaded from Arrow.com.All bus-powered devices have a minimum of 16 analog inputs, digitaltriggering, and two counter/timers. USB M Series devices are idealfor test, control, and design applications including: Portable data logging – log environmental or voltage data quicklyand easily Field-monitoring applications Embedded OEM applications In-vehicle data acquisition Academic lab use – academic discounts availableNI Signal StreamingTo optimize the use of the Universal Serial Bus (USB) and deliver highperformance data acquisition, National Instruments created several keytechnologies to push the limits of USB throughput and latency. NI signalstreaming combines three innovative hardware- and software-leveldesign elements to enable sustained high-speed and bidirectional datastreams over USB. For more information, visit ni.com/usb.

Bus-Powered M Series Multifunction DAQ for USB — 16-Bit, up to 400 kS/s, up to 32 Analog Inputs, IsolationM Series for TestUSB M Series multifunction DAQ devices complement existing test systemsthat need additional measurement channels. For higher-channel-countsignal conditioning on USB, consider the NI CompactDAQ or SCXI platforms.USB M Series for DesignFor design applications, you can use a wide range of I/O – from16 differential analog inputs to 32 digital lines – to measure and verifyprototype designs. USB M Series devices and NI LabVIEW SignalExpressinteractive measurement software deliver benchtop measurements tothe PC. With LabVIEW SignalExpress, you can quickly create designverification tests. You can convert your tested and verified LabVIEWSignalExpress projects to LabVIEW applications for immediate M SeriesDAQ use, and bridge the gap between test, control, and design applications.USB M Series for OEMsShorten your time to market by integrating world-classNational Instruments OEM measurement products in your design. Boardonly versions of USB M Series DAQ devices are available for OEMapplications, with competitive quantity pricing and available softwarecustomization. The NI OEM Elite Program offers free 30-day trial kits forqualified customers. Visit ni.com/oem for more information.Recommended Training and ServicesAll M Series devices are available with additional warrantyand calibration services. For new data acquisition programmers,NI recommends the “Data Acquisition: 7 Steps to Success” tutorial kit.This tutorial kit helps shorten development time for data acquisitionapplications by describing the various stages of getting started with DAQincluding system definition, setup, test, and application programming.Recommended SoftwareNational Instruments measurement services software, built aroundNI-DAQmx driver software, includes intuitive application programminginterfaces, configuration tools, I/O assistants, and other tools designedto reduce system setup, configuration, and development time. NationalInstruments recommends using the latest version of NI-DAQmx driversoftware for application development in NI LabVIEW, LabVIEWSignalExpress, LabWindows/CVI, and Measurement Studio software. Toobtain the latest version of NI-DAQmx, visit ni.com/support/daq/versions.NI measurement services software speeds up your development withfeatures including: A guide to create fast and accurate measurements with noprogramming using the DAQ Assistant Automatic code generation to create your application in LabVIEW;LabWindows/CVI; LabVIEW SignalExpress; and C#, Visual Studio .NET,ANSI C/C , or Visual Basic using Measurement Studio Multithreaded streaming technology for 1,000 timesperformance improvements Automatic timing, triggering, and synchronization routing to makeadvanced applications easy More than 3,000 free software downloads available at ni.com/zoneto jump-start your project Software configuration of all digital I/O features without hardwareswitches/jumpers Single programming interface for analog input, analog output,digital I/O, and counters on hundreds of multifunction DAQhardware devicesM Series devices are compatible with the following versions(or later) of NI application software – LabVIEW, LabWindows/CVI,or Measurement Studio versions 7.x; and LabVIEW SignalExpress 2.x.Recommended Accessories(Mass Terminal Versions)Signal conditioning is required for sensor measurements or voltageinputs greater than 10 V. NI SCC products, which are designed toincrease the performance and reliability of your data acquisition system,are up to 10 times more accurate than using terminal blocks alone.Refer to Table 2 for more information or visit ni.com/sigcon.Sensor/Signals ( 10 V)System DescriptionSCC signal conditioningSensor/Signals ( 10 V)System DescriptionScrew terminal (shielded) 2BNC connectivityScrew terminal (nonshielded) 21 Includes2 SH68-68-EPMR68-68Terminal BlockSCC-68 1BNC-2110SCC-681SCC signal conditioning.the integrated screw terminal version of the USB DAQ device.Table 2. Recommended AccessoriesBUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)2Downloaded from Arrow.com.

Bus-Powered M Series Multifunction DAQ for USB — 16-Bit, up to 400 kS/s, up to 32 Analog Inputs, IsolationOrdering InformationNI USB-6210 screw terminal (Windows) . 779675-01NI USB-6210 screw terminal (Mac OS X and Linux ).780103-01NI USB-6211 screw terminal (Windows) . 779676-01NI USB-6211 screw terminal (Mac OS X and Linux ).780104-01NI USB-6212 screw terminal (Windows) . 780107-01NI USB-6212 mass terminal (Windows) . 780169-01NI USB-6215 screw terminal (Windows) . 779677-01NI USB-6215 screw terminal (Mac OS X and Linux ).780105-01NI USB-6216 screw terminal (Windows) . 780108-01NI USB-6216 mass terminal (Windows) . 780170-01NI USB-6218 screw terminal (Windows) . 779678-01NI USB-6218 screw terminal (Mac OS X and Linux ).780106-01Includes NI-DAQmx or NI-DAQmx Base data acquisition driver software and1 m USB cable.Board-Only Devices for OEMNI USB-6211 OEM1 each . 196203-0310 each . 779803-01NI USB-6212 OEM1 each . 197504-0310 each . 780171-01NI USB-6216 OEM1 each . 197504-0110 each . 780172-01NI USB-6218 OEM1 each . 196203-0110 each . 779805-01Data Acquisition ServicesData Acquisition: 7 Steps to Success. 779489-01BUY NOW!For complete product specifications, pricing, and accessoryinformation, call 800 813 3693 (U.S.) or go to ni.com/daq.BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)3Downloaded from Arrow.com.

Bus-Powered M Series Multifunction DAQ for USB — 16-Bit, up to 400 kS/s, up to 32 Analog Inputs, IsolationSpecificationsRefer to the NI USB-621x Specifications manual at ni.com/manualsfor more detailed information. Specifications listed below are typical at25 C unless otherwise noted.Analog InputNumber of channelsUSB-6210/6211/6212/6215/6216. 8 differential or 16 single endedUSB-6218 . 16 differential or32 single endedADC resolution. 16 bitsSampling rateUSB-6210/6211/6215/6218 . 250 kS/s single channel,250 kS/s multichannel(aggregate)USB-6212/6216 . 400 kS/s single channel,400 kS/s multichannel(aggregate)Input coupling . DCInput rangeUSB-6210/6211/6212/6215/6216/6218. 10, 5, 1, 0.2 VMaximum working voltage for analoginputs (signal common mode) . 10.4 V of AI GNDInput impedanceDevice onAI to AI GND. 10 GΩ in parallel with 100 pFAI- to AI GND. 10 GΩ in parallel with 100 pFDevice offAI to AI GND. 1200 ΩAI- to AI GND. 1200 ΩInput bias current. 100 pACrosstalk (at 100 kHz)Adjacent channels . -75 dBNonadjacent channels . -90 dBInput FIFO size. 4,095 samplesScan list memory . 4,095 entriesData transfers . NI signal streaming on USB,programmed I/OAnalog OutputNumber of channelsUSB-6210.USB-6211/6212/6215/6216/6218.DAC resolution.Maximum update rate1 channel .2 channels.Timing accuracy .Timing resolution .Output range .Output coupling.Output impedance.Output current drive.0216 bits250 kS/s250 kS/s per channel50 ppm of sample rate50 ns 10 VDC0.2 Ω 2 mAOutput FIFO size . 8,191 samples sharedamong channels usedData transfers . NI signal streaming on USB,programmed I/OCalibration (AI and AO)Recommended warm-up time. 15 minutesCalibration interval . 1 yearDigital I/O/PFIStatic CharacteristicsNumber of channelsDigital inputUSB-6210/6211/6215.USB-6218.Digital outputUSB-6210/6211/6215.USB-6218.Digital input/outputUSB-6212/6216 screw terminal.USB-6212/6216 mass terminal.Ground reference .Direction control .48483224D GNDEach terminal individuallyprogrammable as input or outputPull-down resistorUSB-6210/6211/6215/6218 . 47 kΩ 1%USB-6212/6216 . 50 kΩ typical, 20 kΩ minimumPFI FunctionalityUSB-6210/6211/6215/6218Functionality. Static digital input,static digital output,timing input, timing outputTiming output sources. Many AI, AO, counter, DI,DO timing signalsDebounce filter settings . 125 ns, 6.425 µs, 2.56 ms,disable; high and lowtransitions; selectableper inputUSB-6212/6216Functionality. Static digital input,static digital output,timing input, timing outputTiming output sources. Many AI, AO,counter timing signalsDebounce filter settings . 125 ns, 6.425 ms, 2.56 ms,disable; high and lowtransitions; selectableper input timing signalsGeneral-Purpose Counter/TimersNumber of counter/timers . 2Counter measurements. Edge counting, pulse,semiperiod, period,two-edge separationBUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)4Downloaded from Arrow.com.

Bus-Powered M Series Multifunction DAQ for USB — 16-Bit, up to 400 kS/s, up to 32 Analog Inputs, IsolationPosition measurements . X1, X2, X4 quadrature encodingwith Channel Z reloading;two-pulse encodingOutput applications. Pulse, pulse train with dynamicupdates, frequency division,equivalent time samplingInternal base clocks . 80 MHz20 MHz0.1 MHzBase clock accuracy. 50 ppmInputs. Gate, Source, HW Arm,Aux, A, B, Z, Up DownData transfers . NI signal streaming on USB,programmed I/OFrequency GeneratorNumber of channels.Base clocks .Divisors.Base clock accuracy.110 MHz, 100 kHz1 to 1650 ppmOutput can be available on any output PFI line.External Digital TriggersSource . Any input PFIPolarity . Software-selectablefor most signalsAnalog input function . Start TriggerReference TriggerPause TriggerSample ClockConvert ClockSample Clock TimebaseAnalog output function . Start TriggerPause TriggerSample ClockSample Clock TimebaseCounter/timer functions. Gate, Source, HW Arm, Aux, A,B, Z, Up DownBus InterfaceUSB. Hi-Speed USB or full-speed USBNI signal streaming. 4 high-speed data streams;can be used for analog input,analog output, counter/timer 0,counter/timer 1Power RequirementsUSBInput voltage on USB-621xUSB port. 4.5 to 5.25 V in configured stateCaution: Do not exceed 16 mA per DIO pin.Maximum Working VoltageUSB-6210/6211/6212Channel-to-earth ground. 11 V, Measurement Category IUSB-6215/6216/6218Channel-to-earth groundContinuous. 30 Vrms /60 VDCMeasurement Category IWithstand . 840 Vrms /1200 VDCVerified by a 5 s dielectricwithstand testChannel-to-busContinuous. 30 Vrms /60 VDCMeasurement Category IWithstand . 1400 Vrms /1950 VDCVerified by a 5 s dielectricwithstand testCaution: This device is rated for Measurement Category I andthe voltage across the isolation barrier is limited to no greater than30 Vrms/60 VDC/42.4 Vpk continuous. Do not use for measurementswithin categories II, III, or IV.Physical RequirementsEnclosure dimensions (includes connectors)Screw terminal . 16.9 by 9.4 by 3.1 cm(6.65 by 3.70 by 1.20 in.)Mass terminal . 9.3 by 9.4 by 3.1 cm(7.61 by 3.68 by 1.20 in.)I/O connectorUSB-6210/6211/6215Screw terminal . Two 16-position COMBICONUSB-6212/6216/6218Screw terminal . Four 16-position COMBICONUSB-6212/6216Mass terminal . One 68-pin SCSIUSB connector . Series B receptacleScrew terminal wiring . 16 to 28 AWGEnvironmentalOperating temperature .Storage temperature.Humidity .Maximum altitude.Pollution degree (indoor use only).0 to 45 C-20 to 70 C10 to 90% RH, noncondensing2,000 m2Safety and ComplianceSafetyThis product is designed to meet the requirements of the followingstandards of safety for electrical equipment for measurement, control,and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1Note: For UL and other safety certifications, refer to the product labelor visit ni.com/certification, search by model number or product line,and click the appropriate link in the Certification column.Caution: Do not use for measurements within categories II, III, and IV.BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)5Downloaded from Arrow.com.

Bus-Powered M Series Multifunction DAQ for USB — 16-Bit, up to 400 kS/s, up to 32 Analog Inputs, IsolationElectromagnetic CompatibilityThis product is designed to meet the requirements of the followingstandards of EMC for electrical equipment for measurement, control,and laboratory use: EN 61326 EMC requirements; Minimum Immunity EN 55011 Emissions; Group 1, Class A CE, C-Tick, ICES, and FCC Part 15 Emissions; Class ANote: For EMC compliance, operate this device according toproduct documentation.CE ComplianceThis product meets the essential requirements of applicable EuropeanDirectives, as amended for CE marking, as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC)Note: Refer to the Declaration of Conformity (DoC) for this product forany additional regulatory compliance information. To obtain the DoC forthis product, visit ni.com/certification, search by model number orproduct line, and click the appropriate link in the Certification column.Environmental ManagementNI is committed to designing and manufacturing products in anenvironmentally responsible manner. NI recognizes thateliminating certain hazardous substances from our products isbeneficial not only to the environment but also to NI customers.For additional environmental information, refer to the NI and theEnvironment Web page at ni.com/environment. This page containsthe environmental regulations and directives with which NI complies,as well as any other environmental information not included inthis document.Waste Electrical and Electronic Equipment (WEEE)EU Customers: At the end of their life cycle, all products must besent to a WEEE recycling center. For more information about WEEErecycling centers and National Instruments WEEE initiatives,visit ni.com/environment/weee.htm.Management Methods for Controlling Pollution Caused byElectronic Information Products Regulation (China RoHS)BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)6Downloaded from Arrow.com.

INTAPLANMAINNI Services and SupportPDEELOPSERVICENEEDSLOYVDENI has the services and support to meetyour needs around the globe and throughthe application life cycle – from planningand development through deploymentand ongoing maintenance. We offerservices and service levels to meetcustomer requirements in research,design, validation, and manufacturing.Visit ni.com/services.Training and CertificationNI training is the fastest, most certain route to productivity with ourproducts. NI training can shorten your learning curve, save developmenttime, and reduce maintenance costs over the application life cycle. Weschedule instructor-led courses in cities worldwide, or we can hold acourse at your facility. We also offer a professional certification programthat identifies individuals who have high levels of skill and knowledge onusing NI products. Visit ni.com/training.Professional ServicesOur NI Professional Services team is composed of NI applicationsand systems engineers and a worldwide National Instruments AlliancePartner program of more than 600 independent consultants andintegrators. Services rangefrom start-up assistance toturnkey system integration.Visit ni.com/alliance.OEM SupportWe offer design-in consulting and product integration assistance if youwant to use our products for OEM applications. For information aboutspecial pricing and services for OEM customers, visit ni.com/oem.ni.com 800 813 3693National Instruments info@ni.comLocal Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you accessto engineers who speak your language. NI delivers industry-leadingtechnical support through online knowledge bases, our applicationsengineers, and access to 14,000 measurement and automationprofessionals within NI Developer Exchange forums. Find immediateanswers to your questions at ni.com/support.We also offer service programs that provide automatic upgrades toyour application development environment and higher levels of technicalsupport. Visit ni.com/ssp.Hardware ServicesNI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way touse your PXI or PXI/SCXI combination systems right out of the box.Trained NI technicians install the software and hardware and configurethe system to your specifications. NI extends the standard warranty byone year on hardware components (controllers, chassis, modules)purchased with FIS. To use FIS, simply configure your system onlinewith ni.com/pxiadvisor.Calibration ServicesNI recognizes the need to maintain properly calibrated devices forhigh-accuracy measurements. We provide manual calibrationprocedures, services to recalibrate your products, and automatedcalibration software specifically designed for use by metrologylaboratories. Visit ni.com/calibration.Repair and Extended WarrantyNI provides complete repair services for our products. Express repairand advance replacement services are also available. We offerextended warranties to help you meet project life-cycle requirements.Visit 1-101-D 2008 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, NI CompactDAQ, SCXI,and SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of MicrosoftCorporation in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries. Other product and company names listedare trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, orjoint-venture relationship with NI.Downloaded from Arrow.com.

National Instruments, USB has evolved into a core bus of choice for measurement and automation applications. NI M Series devices for USB deliver high-performance data acquisition in an easy-to-use and portable . BNC connectivity SH68-68-EPM BNC-2110 Screw terminal (nonshielded)2 R68-68

Related Documents:

Table 2.1. Si8285 Truth Table IN IN- VDDA State VDDB-VMID State Desaturation State VH VL RDY FLTb H H Powered Powered Undetected Hi-Z Pull-down H H H L Powered Powered Undetected Pull-up Hi-Z H H L X Powered Powered Undetected Hi-Z Pull-down H H X X Powered Unpowered — — — L H X X Powered Powered Detected Hi-Z Pull-down. 1. H L Note:

USB. NI M Series bus-powered multifunction data acquisition (DAQ) devices for USB are optimized for superior accuracy in a small form factor. They provide an onboard NI-PGIA 2 . USB-6216 Screw/68-pin SCSI 16 16 400 2 16 250 24 or 32 DIO 60 V, CAT I USB-6218 Screw 32 16 250 2 16 250 8 DI/8 DO 60 V, CAT I Application and Technology

lsc bus duct system 1. introduction 3 1.1 general specifications 1.2 outstanding feature of lsc bus duct 1.3 cataloging 2. high power distribution (600a 6000a) 9 2.1 general specifications 2.1.1 i-series bus duct 2.1.2 8-series bus duct 2.1.3 f-series bus duct 2.1.4 y-series bus duct 2.2 grounding & ip degree 2.2.1 grounding 2.2.2 ip degree 2.3 .

bus route bus stop pickup time bus route (elos) bus stop (elos) pickup time (elos) 419450 w-28a w soffel ave@n 36th ave 8:12 am w-27ear w soffel ave@n 36th ave 7:06 am 419452 w-26a w le moyne ave@n 38th ave 8:21 am w-27ear w le moyne ave@n 38th ave 6:59 am 420001 w-52a butterfield rd@high

Dell Multifunction Printer E515dw Dell Multifunction Printer E515dn Dell Multifunction Printer E514dw User’s Guide Regulatory Model: Dell E515dw / E515dn / E514dw

200 National Instruments Tel: (800) 433-3488 Fax: (512) 683-9300 info@ni.com ni.com Full-Featured E Series Multifunction DAQ Data Acquisition and Signal Conditioning Full-Featured E Series Multifunction DAQ 12 or 16-Bit, up to 1.25 MS/s, up to 64 Analog Inputs

BUS 101, Introduction to Business 3 BUS 105, Business Mathematics or MATH 115, Statistics or MATH 116, Introduction to Statistics Using R or MATH 124, Finite Math 3-4 BUS 111, Business English 3 BUS 113, Business Communications 3 BUS 121, Fundamentals of Investment and Personal Finance 3 BUS 201, Business Law 3 BUS 212, Women in Organizations 3

Universal Serial Bus Revision 3.2 Specification Universal Serial Bus Revision 3.2 Specification. xxxx and xxxx xxxx and xxxx. Uni-versal Serial Bus Specification Universal Serial Bus Revision 3.2 Specification I2C-Bus Specification I2C-Bus Specification Sys-tem Management Bus Specification