Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmeters OverviewSITRANS F M electromagnetic flowmeters are designed for measuring the flow of electrically conductive mediums.High-powered flowmeters are used for difficult applicationswhere other flowmeters cannot stand up to the task. This flowmeter can handle liquids and heavy slurries in industries such asmining, cement and pulp and paper.The full SITRANS F M program consists of three different typesof flowmeters making Siemens unique in that it covers all possible applications where electromagnetic flowmeters are a suitable match:Modular pulsed DC flowmeters cover all ordinary applicationswithin all industries. The wide variety of combinations and versions from the modular system means that ideal adaptation ispossible to each measuring task and application.3SITRANS F M 911/TRANSMAG 2SITRANS F M productsBattery-operated water meters (fully electronic) are the perfectmatch for drinking water applications like network distribution,revenue metering and irrigation where mains power is not available. In addition, it complies with the MID (EU) and OIML R 49water meter standards and has the MCERTS certificate.SITRANS F M MAG 8000Siemens FI 01 · 20143/13

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersEasier commissioning of MAG 5000, 6000, 6000 I BenefitsAll SITRANS F M pulsed DC electromagnetic flowmeters featurea unique SENSORPROM memory unit which stores sensor calibration data and transmitter settings for the lifetime of the product.At commissioning the flowmeter commences measurementwithout any initial programming.The factory settings matching the sensor size are stored in theSENSORPROM unit. Also customer specified settings are downloaded to the unit. Should the transmitter be replaced, the newtransmitter will upload all previous settings and resume measurement without any need for reprogramming.3Further, the „fingerprint“ used in connection with theSITRANS F M Verificator is stored during the initial sensor calibration.Easier serviceTransmitter replacement requires no programming.SENSORPROM automatically updates all settings after initialization.Room for growthUSM II the Universal Signal Module with "plug & play" simplicity,makes it easy to access and integrate the flow measurementwith almost any system and bus-protocol and it ensures the flowmeter will be easy to upgrade to future communication/bus platforms.Greater flexibility Wide product program Compact or remote installation using the same transmitter andsensor USM II communication platform for easy integration with allsystems ApplicationElectromagnetic flowmeters are suitable for measuring the flowof almost all electrically conductive liquids, pastes and slurries.A prerequisite is that the medium must have a minimum conductivity of 5 S/cm. The temperature, pressure, density and viscosity have no influence on the result.The main applications of the electromagnetic flowmeters can befound in the following sectors: Water and waste water Chemical industries Pharmaceutical industries Food and beverage industry Mining, aggregates and cements industries Pulp and paper industry Steel industry Power; utility and chilled water industryThe wide variety of combinations and versions from the modularsystem means that ideal adaptation is possible to each measuring task.3/14Siemens FI 01 · 2014

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersPlease see product selectoron the Internet, because someconstrains might be related tosome of the m1100MAG1100 HTMAG1100 FMAG3100MAG3100 HTMAG3100 PMAG5100 W911/EMAG 8000/ MAG 8000MAGIrrigation8000 CT7ME6110 7ME6120 7ME6140 7ME6310 7ME6320 7ME6340 7ME6520 7ME6580 7ME5610 7ME68107ME6820IndustryWater / waste waterChemicalPharmaceuticalFood and beverageMining, aggregates and cementHPIOtherDesignCompactRemoteConstant field (DC)Alternating field (AC)Battery-operated constant field(DC)SizeDN 2 (1/12“)DN 3 (1/8“)DN 6 (1/4“)DN 10 (3/8“)DN 15 (½“)DN 25 (1“)DN 32 (1¼“)DN 40 (1½“)DN 50 (2“)DN 65 (2½“)DN 80 (3“)DN 100 (4“)DN 125 (5“)DN 150 (6“)DN 200 (8“)DN 250 (10“)DN 300 (12“)DN 400 (16“)DN 450 (18“)DN 500 (20“)DN 600 (24“)DN 700 (28“)DN 750 (30“)DN 800 (32“)DN 900 (36“)DN 1000 (40“)DN 1050 (42“)DN 1100 (44“)DN 1200 (48“)DN 1400 (54“)DN 1500 (60“)DN 1600 (66“)DN 1800 (72“)DN 2000 (78“)XXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXX XXXXXXX 7ME6880XXXXXXXXXXXX available, X can be used, XX often used, XXX most often usedSiemens FI 01 · 20143/153

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersPlease see product selectoron the Internet, because someconstrains might be related tosome of the m1100MAG1100 HTMAG1100 FMAG3100MAG3100 HTMAG3100 PMAG5100 W911/EMAG 8000/ MAG 8000MAGIrrigation8000 CT7ME6110 7ME6120 7ME6140 7ME6310 7ME6320 7ME6340 7ME6520 7ME6580 7ME5610 7ME68107ME682037ME6880Process connectionWafer design Sanitary process connections 3)EN 1092-1 3)ANSI B 16.5 class 150 3)ANSI B 16.5 class 300 ASME B 16.47 class 150 AWWA class D AS 2129 AS 4087, PN 16 AS 4087, PN 21 AS 4087, PN 35 JIS 10K JIS 20K FlangesFlange norms 3) Pressure rating 1) PN 6PN 10PN 16PN 25PN 40PN 63PN 100Accuracy 0.2 % 0.4 % 0.5 % 0.8 % Grounding electrodes, incl. 2)Grounding rings premountedfrom factory available1)Pressure may be limited by the liner material chosenNot for PTFE liner.Drilled pattern flange max. 7 bar (107 psi).4)Optional on PFA2)3)3/16Siemens FI 01 · 2014 4) ( )

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersPlease see product selectoron the Internet, because someconstrains might be related tosome of the m1100MAG1100 HTMAG1100 FMAG3100MAG3100 HTMAG3100 PMAG5100 W911/EMAG 8000/ MAG 8000MAGIrrigation8000 CT7ME6110 7ME6120 7ME6140 7ME6310 7ME6320 7ME6340 7ME6520 7ME6580 7ME5610 7ME68107ME68207ME6880Materials/temperature:3Liner material/max . temperaturesNBR Hard Rubber: 70 C(158 F) EPDM: 70 C (158 F) Soft rubber: 70 C (158 F) PTFE: 100 C (212 F) PTFE: 130 C (266 F) PTFE: 180 C (356 F) Ebonite Hard Rubber: 95 C(203 F)Ceramic: 150 C (302 F) ( )1) 3) 3) 2)Ceramic: 200 C (392 F)PFA: 100 C (212 F)PFA: 150 C (302 F) Linatex: 70 C (158 F) Novolak: 130 C (266 F) ElectrodesStainless steelHastelloy C Platinum Titanium Tantalum Carbon steel Stainless steel / carbon steel Flange/housing materialPolished stainless steel ApprovalsCustody transferCold water - MI-001 (EU) Cold water approval OIML R 49/OIML R 49 MAA 7)Cold water pattern approval OIML R 49 (Denmark) 7)Cold water pattern approvalPTB (Germany) 7) 7) 7)Hot water pattern approval PTB (Germany) 7) 7) 7)Other media than water patternapproval - OIML R 117(Denmark) 7) 7) 7)Chilled water pattern approvalPTB K 7.2 7)OE12/C 040 (Austria)Chilled water pattern approval 7) available1)150 C (302 F)Ex sensor: 180 C (356 F)3)70 C (158 F)2)Siemens FI 01 · 20143/17

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersPlease see product selectoron the Internet, because someconstrains might be related tosome of the m1100MAG1100 HTMAG1100 FMAG3100MAG3100 HTMAG3100 PMAG5100 W911/EMAG 8000/ MAG 8000MAGIrrigation8000 CT7ME6110 7ME6120 7ME6140 7ME6310 7ME6320 7ME6340 7ME6520 7ME6580 7ME5610 7ME68107ME682037ME6880Approvals (continued)Hazardous areasATEX - 2 GD (Zone 1/21) IECEx Gb Zone 1/21FM Class I, Div 1FM Class I, Zone 1FM Class I, Div 2 10) 10) 10) CSA Class I, Zone 1/21 CSA Class I, Div 2 4) 5) ACS (FR) EPDM liner Belgaqua (B) EPDM liner HygienicEHEDG 3A EC 1925:2003European food contact material Drinking waterWRAS (WRc) - (UK)ANSI/NSF 61(US)9)DVGW-W270 (D) EPDM liner MCERTS (UK environmental) 6) 4) 8) 8) OtherFM Fire Service(class number 1044)GOSS/GOST (Russia ) CRN (Canada) 1)PED 97/23 EC 1) 9) 9) 3)VdSOther national approvals, seeinternet 9) 9) 9) 9)Verificator compatible 2) 2) 2) 2) available6)1)7)Only PFA liner.2)Only in combination with MAG 5000 and MAG 6000 transmitters.3) Only valid for DN 50 to DN 300 (2" to 12")4)EPDM liner5)Only EPDM with Hastelloy electrodes3/18 Siemens FI 01 · 2014 9) 9) 9) 9) 2) 2) 2) 2)EPDM or PTFE liner with AISI 316 or Hastelloy electrodes.For verification submit Product Variation Request8)Sizes: DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3",4", 6", 8", 10", and 12") with ANSI B16.5 Class 150 flanges9) Including Annex G10)Only DN 15 to DN 300 (½" to 12") with MAG 6000 I Ex, compact mounted

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersPlease see Product selector on theInternet, because some constrainsmight be related to some of the G 5000MAG 6000MAG 6000 IMAG 6000 IExMAG 6000 Ex SafetybarrierTRANSMAG 2MAG8000MAG 8000/MAG 8000 CT XXXIndustryWater / waste waterChemicalPharmaceuticalXXXXXXXFood and beverageXXXXXXXMining, aggregates and cementXXXXXXXXXXXXXXXXXXXCompact Remote Constant field (DC) HPIOtherXXXXXXXXXDesignAlternating field (AC) 1) 1) Battery-operated constant field (DC)Enclosure transmitterPolyamide, IP67 Die-cast aluminum Stainless steel 19“ rack Back of panel Panel mounting IP67 wall mounting Accuracy0.2 %0.4 % 0.5 % 0.8 % CommunicationHART PROFIBUS PA PROFIBUS DP FOUNDATION Fieldbus H1 DeviceNet Modbus RTU/RS 485 Encoder interface module (Sensusprotocol) for Itron 200WP radioGSM/GPRS moduleBatching 2) 2) available, X can be used, XX often used, XXX most often used1)2)IP68 enclosureModbus RTU also as serial RS 232Siemens FI 01 · 20143/193

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersPlease see Product selector on theInternet, because some constrainsmight be related to some of the G 5000MAG 6000MAG 6000 IMAG 6000 IExMAG 6000 Ex SafetybarrierTRANSMAG 2MAG8000MAG 8000/MAG 8000 CT 347ME68107ME68207ME6880 1) 1) 1) 2) 1) 2) 2) 2)Power supply324 V115 V - 230 V BatteryApprovalsCustody transferCold water - MI-001 (EU) Cold water pattern approval OIML R 49 (Denmark) Cold water approval OIML R 49/OIML R 49 MAACold water pattern approval PTB(Germany) Chilled water pattern approvalPTB K 7.2 Hot water pattern approval PTB(Germany) Other media than water patternapproval - OIML R 117 Denmark OE12/C 040 (Austria)Chilled water pattern approval Hazardous areasATEX - 2 GD (Zone 1/21) IECEx Gb Zone 1/21 4)FM Class I, Div 1FM Class I, Zone 1FM Class I, Div 2/Zone 2( )3) CSA Class I, Div 2 UL / C-UL- general safety FM Fire Service (1044) C - tick (Australia ) GOSS / GOST (Russia ) VdS Other national approvals, seeinternet Verificator compatible CSA Class I, Zone 1/21 Other 1)12/24 V AC/DCMain power with battery backup3)Only sensor in hazardous area4)Only with sensors sizes DN 15 to DN 300 (½" to 12") compact2)For more national approvals please check our internet en/10806954/134200Siemens FI 01 · 2014 available3/20

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmeters Practical examples of orderingSITRANS F M compact installationSITRANS F M remote installation Wall bracketMAG 6000transmitter MAG 3100sensorMAG 6000 MAG 6000 compactmounted on aMAG 3100 sensorExampleMAG 31002 x cableSensor7ME6310-3TC11-1JA1Pipe sizeDN 100LinerSoft rubberSensor7ME6310-3TC11-1AA1ElectrodesSS 316Pipe sizeDN 100FlangesEN 1092-1, PN 16LinerSoft rubberTransmitterMAG 6000, Polyamide, 115 . 230 V ACElectrodesSS 316Accuracy 0.2 % 1 mm/sFlangesEN 1092-1, PN 16230 V ACTransmitter7ME6920-1AA10-0AA0Accuracy 0.2 % 1 mm/sSupply230 V ACWall mounting kitFDK:085U1018Cable kit with sensorcabel and electrodecableA5E01181647SupplyNote:MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation atthe customer's place.3 MAG 3100 remoteinstallationExampleSiemens FI 01 · 20143/21

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmeters Technical specificationsFlowmeter Calibration and traceabilitySiemens offers accredited calibrations assured to ISO 17025 inthe flow range from 0.0001 m³/h to 10 000 m³/h.Siemens Flow Instruments accredited laboratories are recognized by ILAC MRA (International Laboratory Accreditation Corporation - Mutual Recognition Arrangement) ensuring international traceability and recognition of the test results worldwide.To ensure continuous accurate measurement, flowmeters mustbe calibrated. The calibration is conducted at Siemens flow facilities with traceable instruments referring directly to the physical unit of measurement according to the International System ofUnits (SI).A calibration certificate is shipped with every sensor and calibration data are stored in the SENSORPROM memory unit.Therefore, the calibration certificate ensures recognition of thetest results worldwide, including the US (NIST traceability).3Flowmeter uncertaintyMAG 5000 with MAG 1100, MAG 1100 F, MAG 5100 W, MAG 3100, MAG 3100 Pand MAG 6000 with MAG 1100 (PFA), MAG 1100 F (PFA)Flowmeter uncertainty[ % E]3,02,8V: Flow velocityE: Meter uncertainty as a percentage of measured valuev 0.1 m/s (0.3 ft/s) -- E: 0.4 1 mm/s *v 0.1 m/s (0.3 ft/s) -- E: (0.25/v) % of measured value2,62,42,2* MAG 5100 W (Article No. 7ME652.) DN 350 . 1200v 0.1 m/s (0.3 ft/s) -- E: 0.4 2 mm/sv 0.1 m/s (0.3 ft/s) -- E: (0.25/v) % of measured value2,01,8* MAG 1100 with PFA liner DN 10 and DN 40v 0.1 m/s (0.3 ft/s) -- E: 0.4 2 mm/sv 0.1 m/s (0.3 ft/s) -- E: (0.25/v) % of measured /s]03.36.69.9131620232630333639[ft/s]MAG 6000 and MAG 6000 I with MAG 1100 (not PFA), MAG 1100 F (not PFA), MAG 5100 W, MAG 3100 and MAG 3100 P[ % E]Flowmeter uncertainty1.4V: flow velocityE: meter uncertainty as a percentage of measured valuev 0,1 m/s (0.3 ft/s) -- E: 0,2 1 mm/s *v 0,1 m/s (0.3 ft/s) -- E: (0,125/v) % of measured value *1.21.0* MAG 5100 W (Article No. 7ME652.) DN 350 . 1200v 0,1 m/s (0.3 ft/s) -- E: 0,2 2,5 mm/sv 0,1 m/s (0.3 ft/s) -- E: (0,25/v) % of measured value0.8* MAG 1100 and MAG 1100F with ceramic liner DN 10 and DN 40v 0.1 m/s (0.3 ft/s) -- E: 0.2 2 mm/sv 0.1 m/s (0.3 ft/s) -- E: (0.125/v) % of measured value0.60.40.20.0003/22Siemens FI 01 · ][ft/s]

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersReference conditionsReference conditions (ISO 9104 and DIN EN 29104)Temperature medium20 C 10 K (68 F 18 F)Temperature ambient25 C 10 K (77 F 18 F)Supply voltageUn 1 %Warming-up time30 minutesIncorporation in conductive pipesection Inlet section10 x DN (DN 1200/48”)5 x DN (DN 1200/48“) Outlet section5 x DN (DN 1200/48”)3 x DN (DN 1200/48“)Flow conditionsDeveloped flow profile3Additions in the event of deviations from reference conditionsCurrent outputAs pulse output ( 0.1 % of actualflow 0.05 % FSO)Effect of ambient temperature Display / frequency / pulse output 0.003 %/K act. Current output 0.005 %/K act.Effect of supply voltage 0.005 % of measuring value on1% changeRepeatability 0.1 % of actual flow forv 0.5 m/s (1.5 ft/s) and conductivity 10 S/cmCertificates EN 10204-2.1Certificate of conformity, statingthat the delivered parts are madeof the material quality that wasordered. Available as Z optionC15. EN 10204-2.2Test report certificate, a nonbatch specific material analysis ofthe ordered material. Available asZ option C14. EN 10204-3.1Material analysis certificate, abatch specific analysis of thematerial issued by an independent inspector.Certification covers all pressurecontaining and wetted parts.Siemens FI 01 · 20143/23

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmeters Technical specificationsGeneral specifications3IS (Intrinsic Safety) dataPROFIBUS device profile3.00 Class BRequired sensor electronicsCertifiedYes, according to Profile for processcontrol devices v3.00.Compact or remote mountedSITRANS F M MAG 6000 I ExFISCOYesMS0 connections1Max. UI17.5 VMS1 connections1Max. II380 mAMS2 connections2Max. PI5.32 VElectrical specification DPMax. LI0 HPhysical layer specificationsMax. CI0 nFApplicable standardIEC 61158/EN 50170FISCO cable requirementsLoop resistance RC15 . 150 /kmLoop inductance LC0.4 . 1 mH/kmPhysical Layer (Transmissiontechnology)RS 485Transmission speed 1.5 Mbits/sCapacitance CC80 . 200 nF/kmNumber of stationsUp to 32 per line segment, (maximumtotal of 126)Max. Spur length in IIC and IIB30 mMax. Trunk length in IIC1 kmMax. Trunk length in IIB5 kmCable specification (Type A)Cable designTwo-wire twisted pairShieldingCU shielding braid or shielding braidand shielding foilImpedance35 up to 165 at frequencies from3 . 20 MHzCable capacity 30 pF per meterCore diameter 0.34 mm², corresponds to AWG 22Resistance 110 per kmSignal attenuationMax. 9 dB over total length of linesectionMax. bus lengthPROFIBUS parameter supportThe following parameters are accessible using a MS0 relationship from a Class 1 Master.MS0 specifies cyclic Data Exchange between a Master and aSlave.Cyclic servicesInput (Master view)ParameterMAG 6000/MAG 6000 IMass flowVolume flow Temperature200 m at 1500 kbit/s, up to 1.2 km at93.75 kbit/s. Extendable by repeatersDensityElectrical specification PAFraction A1)Physical layer specificationsFraction B1)Applicable standardIEC 61158/EN 50170Pct Fraction A1)Physical Layer (Transmissiontechnology)IEC-61158-2Totalizer 1 Totalizer 22) Transmission speed31.25 Kbits/secondBatch progress2) Number of stationsUp to 32 per line segment, (maximumtotal of 126)Batch setpoint Max. basic current [IB]14 mABatch compensation Fault current [IFDE]0 mABatch status (running .) Bus voltage9 . 32 V (non Ex)Output (Master view) Set Totalizer 1 2Preferred cable specification(Type A)Cable designTwo-wire twisted pairConductor area (nominal)0.8 mm2 (AWG 18)Loop resistance44 /km Batch control(start, stop .) Batch setpoint Batch compensation 1)Requires a SENSORPROM containing valid fraction data.2)Value returned is dependent on the BATCH function.Impedance100 20 %Wave attenuation at 39 kHz3 dB/kmWhen ON, Batch progress is returned.Capacitive asymmetry2 nF/kmWhen OFF, TOTALIZER 2 is returned.Bus terminationPassive line termination at bothMax. bus lengthUp to 1.9 km. Extendable by repeaters3/24Siemens FI 01 · 2014 Set Mode Totalizer 1 2

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersSelection of sensorMetricm3/hI/min.2 · 10 6100 00050 00020 0000180DN 0 041DN0110DN 009DN70 0DN50 0DN004DN003DN10 0005 0002 0001 000500200DN10020 0020 0DN0016DN0120ND0001DN 080DN600DN450DN 035ND25 0DN10 62 · 10 45 · 10 510 45 0002 · 10 55 · 1010 0DN N80D65DN20D2DN10 10.05210.05220100.110510DN0.22020010.55005040DN1 000200010542 · 10 4150D N 251DN32 00010 50.10.15 0.20.30.511.52510 m/s0.00020.00010.00005)ORZ YHORFLW\Sizing table (DN 2 DN 2000)The table shows the relationship between flow velocity v, flowquantity Q and sensor dimension DN.Guidelines for selection of sensorMin. measuring range: 0 to 0.25 m/sFlow velocity calculation formula Unitsv 1273.24 Q / DN2 orv : [m/s], Q : [l/s], DN : [mm]v 353.68 Q / DN2v : [m/s], Q : [m3/h], DN : [mm]Max. measuring range: 0 to 10 m/sNormally the sensor size is selected so that the nominal flow velocity v lies within the measuring range 1 to 3 m/s.Link to "Sizing program":https://pia.khe.siemens.com/index.aspx?nr 11501Example:Flow quantity of 50 m3/h and a sensor dimension of DN 80 givesa flow velocity of 2.7 m/s, which is within the recommendedmeasuring range of 1 to 3 m/s.Siemens FI 01 · 20143/25

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersImperialGPMMGD1 000500 000500200 000200I/min.2 000 0001 000 000500 000100 00010078 "66"72 " " 5 4"604"48" 42" 36"4/"4030"32 "4"28 " 28""20 14""16112 " 10 "503201052150 00020 00050 0005 0002 0000.10.05200502"3 /81001050201025"10.0010.51/4"0.000520020"1/20.0021 00050050.0052 0001001"0.0110 0005 0001½"0.0220 0001 0005006"5"4"3""2½0.2100 00010 0008"0.5200 10.0020.0000020.00050.0010.0000010.10.15 0.20.30.50.811.52351015 2030 33 f/sFlow velocitySizing table (1/12” 78”)The table shows the relationship between flow velocity v, flowquantity Q and sensor dimension size.Guidelines for selection of sensorMin. measuring range: 0 to 0.8 ft/sFlow velocity calculation formula Unitsv 0.408 Q / (Pipe I.D.)2 orv : [ft/s], Q : [GPM], Pipe I.D. : [inch]v 283.67 Q / (Pipe I.D.)2v : [ft/s], Q : [MGD], Pipe I.D. : [inch]Max. measuring range: 0 to 33 ft/sNormally the sensor size is selected so that the nominal flow velocity v lies within the measuring range 3 to 10 ft/s.Example:Flow quantity of 500 GPM and a sensor dimension of 6" gives aflow velocity of 5.6 ft/s, which is within the recommended measuring range of 3 to 10 ft/s.3/26Siemens FI 01 · 2014Link to "Sizing program":https://pia.khe.siemens.com/index.aspx?nr 11501

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersInstallation conditionsVibrationsFor partially filled pipes or pipes with downward flow and freeoutlet the flowmeter should be located in a U-Tube.Strong vibrations should be avoided.In applications with strong vibrations, remote mounting of thetransmitter is recommended.3Install in U-tubes when pipe is partially filledInstallation in vertical pipesRecommended flow direction: upwards. This minimizes theeffect on the measurement of any gas/air bubbles in the liquid.The sensor must always be completely filled with liquid.Install in vertical pipes with upward flow directionInstallation in horizontal pipesInstall in pipelines which are always fullThe sensor must always be completely filled with liquid. Therefore avoid: Installation at the highest point in the pipe system Installation in vertical pipes with free outletThe sensor must be mounted as shown in the below figure. Donot mount the sensor as shown in the lower figure. This will position the electrodes at the top where there is possibility for airbubbles and at the bottom where there is possibility for mud,sludge, sand etc. Do not install in pipelines which can run emptySiemens FI 01 · 20143/27

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersMeasuring abrasive liquids and liquids containing particlesRecommended installation is in a vertical/inclined pipe to minimize the wear and deposits in the sensor.3Potential equalizationPotential equalizationInstall in vertical pipelines with upward flow direction if measuring abrasive liquidsInlet and outlet conditionsmin. 5 x Dimin. 3 x DiThe electrical potential of the liquid must always be equal to theelectrical potential of the sensor. This can be achieved in different ways depending on the application: Wire jumper between sensor and adjacent flange (MAG 1100,MAG 3100) Direct metallic contact between sensor and fittings(MAG 1100 F) Build-in grounding electrodes (MAG 3100, MAG 5100 W) Optional grounding/protection flanges/rings (MAG 1100,MAG 3100, MAG 8000) Optional graphite gaskets on MAG 1100 (standard forMAG 1100 High Temperature) MAG 8000 installed in plastic or coated pipes: two groundingrings to be used.GroundingInstallation between elbows, pumps and valves: standard inlet and outletpipe sectionsTo achieve maximum accurate flow measurement it is essentialto have straight length of inlet and outlet pipes and a certain distance between the flowmeter and pumps or valves.It is also important to center the flowmeter in relation to pipeflange and gaskets.MAG 3100 (not PTFE), MAG 5100 W: with earthing electrodes in conductive and non-conductive pipes (no further action necessary)M6 x 16Ambient temperature-InstallationTemperature changes can cause expansion or contraction in thepipe system. To avoid damage on the sensor use of proper gasket and torque should be ensured. For more information see sensor instruction.MAG 1100, MAG 3100 (PTFE): without earthing electrodes in conductivepipes (MAG 1100 use graphite gasket)3/28Siemens FI 01 · 2014

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersΔp [psi] Δp out earthing electrodes in non-conductive pipes use grounding ring(MAG 1100 use graphite gasket)MAG 1100 F grounding via process connections. MAG 8000grounding see MAG 8000 50.40.00450.30.00300.20.00150.10.60.70.80.93V 8 m/s[25 ft/sec.]V 7 m/s[23 ft/sec.]V 6 m/s[20 ft/sec.]V 5 m/s[16 ft/sec.]VacuumAvoid a vaccum in the measuring pipe, because this can damage certainliners.1V 4 m/s[13 ft/sec.]V 3 m/s[10 ft/sec.]V 2 m/s[6 ft/sec.]V 1.5 m/s[5 ft/sec.]V 1 m/s[3 ft/sec.]0.50.60.80.70.91d1 /d2Installation in large pipesPressure drop as function of diameter reduction between reducersExample:α 8 d2d1αFlow velocity (v) of 3 m/s (10 ft/s) in a sensor with a diameter reduction DN 100 (4”) to DN 80 (3”) (d1/d2 0.8) gives a pressuredrop of 2.9 mbar (0.04 psi).Ambient temperatureAmbient temp.C (F )Reduction in nominal pipe diameter60 (140)The flowmeter can be installed between two reducers (e.g.DIN 28545). Assuming that at 8 the following pressure dropcurve applies. The curves are applicable to water.50 (122)MAG 6000 I/MAG 6000 I ExMAG 5000/600040 (104)30 (86)20 (68)10 (50)Temperatureof medium0 (32)50(12275167100212125257150 C 302 F )Max. ambient temperature as a function of temperature of mediumThe transmitter can be installed either compact or remote.With compact installation the temperature of medium must beaccording to the graph.Siemens FI 01 · 20143/29

Siemens AG 2013Flow MeasurementSITRANS F MSystem information SITRANS F Melectromagnetic flowmetersSensor cables and conductivity of mediumNoteFor detection of empty pipe the minimum sensor conductivitymust always be 20 S/cm and the maximum length of electrode cable when remotely mounted is 50 m (150 ft). Specialshield cable must be used.For DN 2 and DN 3 empty sensor cannot be detected, and theminimum conductivity must be 30 S/cm.For 19" safety barrier no special cables can be used.Compact installation:Liquids with an electrical conductivity 5 S/cm.3Remote installationStandard cable[μS/cm]300200Conductivityof medium10055150 300300 [m]200100600Cabel length900[ft]Minimum conductivity of medium (using standard electrode cable)Special cable[μS/cm]5040Conductivityof medium302010550 100200150 300 600300400500900 1200 1500[m][ft]Cable lengthMinimum conductivity of medium (using special electrode cable)3/30Siemens FI 01 · 2014

Siemens AG 2013Flow MeasurementSITRANS F MSITRANS F M VerificatorSITRANS F M diagnostics FunctionB Magnetic flux density which permeates the flowing mediumperpendicular to the flow direction.The diagnostic functions are all internal tools in the meter: Identification in clear text and error log Error categories: function; warning; permanent and fatalerrors Transmitter self-check including all outputs and the accuracy Sensor check: coil and electrode circuit test Overflow Empty pipe: partial filling; low conductivity; electrode foulingv flow velocity of mediumSITRANS F M Verificator (MAG 5000 and 6000)d internal diameter of metering tubeThe SITRANS F M Verificator is an external tool designed forMAG 5000 and MAG 6000 with MAG 1100, MAG 1100 F,MAG 3100, MAG 3100 P or MAG 5100 W sensors to verify theentire product, the installation and the application.All electromagnetic flowmeters are based on Faraday’s law of induction:UM B v d kUM Measured voltage induced in the medium perpendicular tothe magnetic field and the flow direction. The voltage is tappedat two point electrodes.k proportionality factor or sensor constantSensorThe goal is to improve operation, reduce downtime and maintainmeasurement accuracy as long as possible.The SITRANS F M Verificator is highly advanced and carries outthe complex verification and performance check of the entireflowmeter system, according to unique Siemens patented principles. The whole verification test is automated and easy to operate so there is no opportunity for human error or influence. Thesystem is traceable to international standards and tested byWRc (Water Research Council).UMVdBFunction and measuring principle of electromagnetic measurementAn electromagnetic flowmeter ge

4) Optional on PFA Please see product selector on the Internet, because some constrains might be related to some of the features: www.pia-selector.automation. siemens.com MAG 1100 MAG 1100 HT MAG 1100 F MAG 3100 MAG 3100 HT MAG 3100 P MAG 5100 W 911/E MAG 8000/ MAG 8000 CT MAG 8000 Irrigation

Related Documents:

College Catalog 2015-2016 College Catalog 2014-2015 College Catalog 2013-2014 College Catalog 2012-2013 College Catalog 2011-2012 College Catalog 2010-2011 Degree and Certificate Programs For each program, you will find information on. entry requirements, required and elective. courses, potential career and/or transfer opportunities, expected .

Catalog C-1 RT306V-TS RECEIVER: 470122 Catalog C-1: RT308V-TR RECEIVER 469996: Catalog C-1 RT3510V2S-KS RECEIVER: 470123 Catalog C-1: RT510V3S-KS RECEIVER 470124: Catalog C-1 RT612V3S-KS RECEIVER: 470125 Catalog C-1: RT616V3S-KS RECEIVER 470126: Catalog C-1 RT618V4S-KS RECEIVER: 470127 Catalog C-1: RT

September: 2013 33,391.18 9/24/2013 October: 2013 33,391.18 10/24/2013 December: 2013 65,031.50 12/20/2013 January: 2014 33,099.37 1/23/2014 February: 2014 33,099.37 2/24/2014 March: 2014 33,099.37 3/24/2014 April: 2014 31,662.23 4/25/2014 May: 2014 31,662.23 5/22/2014 June: 2014 31,662.24 6/26/2014 392,881.03

2020–2021 UMGC Catalog. and represents changes and additions made after original publication. Refer to the . 2020–2021 Catalog. for information on all other programs, services, and policies. 2020 2021 UMGC Catalog . 2020 2021 UMGC Catalog . 2020 2021 Catalog . 2020 2021 Catalog . ABO

Consumer Door Hardware Catalog Volume 2012 2012 Commercial & Residential Door Hardware Catalog Volume 2012 Your Best Source For Quality Door Hardware Your Best Source For Quality Door Hardware S.Parke r Catalog S.Parke r Catalog SPH-Catalog

Program description from the 2004-2006 Graduate Catalog Biostatistics (Ph.D., M.S.) Program description from the 2004-2006 Graduate Catalog Breast Cancer Training Program Program Description from the 2004-2006 Graduate Catalog Business Administration (M.B.A.) Program description from the 2004-2006 Graduate Catalog C Cell Biology (Ph.D.) Catalog .

Step4 In the Work pane, click the Catalog Update Tasks tab. Step5 Click Activate Catalog. Step6 In the Activate Catalog dialog box, choose the capability catalog update that you want to activate from the Version to be Activated drop-down list. Step7 Click OK. Verifying thattheCapability Catalog IsCurrent Procedure Step1 In the Navigation pane, click Admin. Step2 Expand All Capability Catalog.

STM32 32-bit Cortex -M MCUs Releasing your creativity . What does a developer want in an MCU? 2 Software libraries Cost sensitive Advanced peripherals Scalable device portfolio Rich choice of tools Leading edge core Ultra-low-power . STM32 platform key benefits More than 450 compatible devices Releasing your creativity 3 . STM32 a comprehensive platform Flash size (bytes) Select your fit .