Smart-UPS 230 V - Riello, APC UPS UPS Battery .

2y ago
17 Views
2 Downloads
4.07 MB
8 Pages
Last View : 4d ago
Last Download : 3m ago
Upload by : Roy Essex
Transcription

aintenance-free sealed lead-acid battery with suspended electrolyte; leak proofAPCRBC123APCRBC132APCRBC88APCRBC133RBC43200 W:241:101:32:271:241:26500 W:05:17:26:12:35:38600 W:12:19:09:28:31700 W:09:14:07:24:26:07:04:15:17Runtime estimates1,000 W1,400 W:09:111,600 W:07:09:05:03Full load:06:09:07:04Communication and managementInterface portsSerial (RJ45), USB, and SmartSlotAlpha-numeric LCD display with LED status indicators; alarm on battery,distinctive low-battery alarm and configurable delaysControl panel andaudible alarmsEmergency power off (EPO)OptionalYesPhysicalMaximum height – cm (in.)8.9 (3.5)8.9 (3.5)4.4 (1.75)8.9 (3.5)8.6 (3.39)8.6 (3.39)Maximum width – cm (in.)43.2 (17.0)43.2 (17.0)43.2 (17.0)43.2 (17.0)48.0 (18.9)48.0 (18.9)Maximum depth – cm (in.)40.6 (16.0)45.7 (18.0)66.0 (26.0)45.7 (18.0)68.3 (26.9)68.3 (26.9)Net weight kg (lb.)17.27 (38.0)28.18 (62.0)24.09 (53.0)28.64 (63.0)42.31 (93.0)44.28 (97.4)ConformanceRegulatoryWarranty6C-tick, CE, EN62040-1, EN62040-2, EN60950-1, GOST, VDE3-year electronics, 2-years battery

Extended Run Rack/Tower Convertible 2U modelsProduct featureSMX750ISMX1000ISMX1500RMI2U* SMX2200RMHV2U SMX3000RMHV2U*600 W/750 VA800 W/1,000 VAOutputPower capacityNominal output voltage1,200 W/1,500 VAOutput frequency2,700 W/3,000 VA200/208/220/230/240 V47 – 53 Hz for 50 Hz nominal; 57 – 63 Hz for 60 Hz nominalWaveform typeOutput connections (Switched groups)1,980 W/2,200 VA230 V (also configurable to 220 or 240 V nominal)Sine wave(8) IEC320 C13 outlets(750 has 1 group, 1000 has 2 groups, 1500 has 3 groups)(8) IEC320 C13 and (1) IEC320 C19 outlets(3 switched outlet groups)230 V200 – 240 V160 – 286 V (150 – 300 V)140 – 280VInputNominal input voltageInput voltage range for main operations)Max adjustable range(Input frequency50/60 Hz /- 3 Hz (auto sensing)Input connectionIE C320 C14IE C320 C20Batteries and runtimeBattery typeMaintenance-free sealed lead-acid battery with suspended electrolyte; leak proofReplacement battery (UPS)APCRBC116External Battery PackReplacement battery (XBP)Typical back up time at other loadconditions, and with externalbattery BC115APCRBC118Please refer to www.apc.com for runtime chartsCommunication and managementInterface portsControl panel and alarmsSerial (RJ45), USB and Smartslot (Note: models denoted with asterisk * are also available in “NC” version withpre-installed AP9631 network management card.)Alphanumeric LCD display with LED status indicators; alarm on battery, distinctive low battery alarm,and configurable delaysEmergency power off (EPO)YesSurge protectionSurge energy ratingFiltering540 JFull-time multi-pole noise filtering: 0.3% IEEE surge let-through, zero clamping response time,meets UL 1449PhysicalMaximum height – cm (in.)8.9 (3.5) (2U)Maximum width – cm (in.)43.2 (17.0)Maximum depth – cm (in.)Net weight kg (lb.)49.3 (19.0)(48.5)22.9 (50.3)66.7 (26.26)24.8 (54.6)37.3 (82.1)ConformanceRegulatoryWarrantyC-tick, CE, EN62040-1, EN62040-2, EN60950-1, GOST, VDEC-tick, CE, EN62040-1, EN62040-2, EN60950-1,GOST, VDE, UL 17783-years electronics, 2-years battery7

Extended Run Rack/Tower Convertible 4U Short Depth modelsProduct featureSMX2200HVSMX3000HV*1,980 W/2,200 VA2,700 W/3,000 VAOutputPower capacityNominal output voltage230 V (user selectable 200 – 240 V)Output frequency57 – 63 HzWaveform typeSine waveOutput connections (3 switched outlet groups)(8) IEC320 C13 and (2) IEC320 C19 outletsInputNominal input voltageInput voltage range for main operations (Max adjustable range)230 V (user selectable 200 – 240 V)140 – 280VInput frequency50/60 Hz /- 3 Hz (auto sensing)Input connectionIE C320 C20Batteries and runtimeBattery typeReplacement battery (UPS)External Battery PackReplacement battery (XBP)Typical back up time at other load conditions, andwith external battery packsMaintenance-free sealed lead-acid battery with suspended electrolyte; leak proofAPCRBC143SMX120BPAPCRBC143Please refer to www.apc.com for runtime chartsCommunication and managementInterface portsControl panel and alarmsEmergency power off (EPO)Serial (RJ45), USB and SmartSlot (Note: models denoted with asterisk * are alsoavailable in “NC” version with pre-installed AP9631 network management card.)Alphanumeric LCD display with LED status indicators; alarm on battery,distinctive low battery alarm, and configurable delaysYesSurge protectionSurge energy ratingFiltering540 JFull-time multi-pole noise filtering: 0.3% IEEE surge let-through,zero clamping response time, meets UL 1449PhysicalMaximum height – cm (in.)43.2 (17)Maximum width – cm (in.)17.8 (7)Maximum depth – cm (in.)48.3 (19)Net weight kg – kg (lb.)38.6 (85)ConformanceRegulatoryWarrantyC-tick, CE, EN62040-1, EN62040-2, EN60950-1, GOST, VDE, UL 17783-years electronics, 2-years battery 2013 Schneider Electric. All Rights Reserved. Schneider Electric, APC, Smart-UPS, and SmartSlot are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All othertrademarks are the property of their respective owners. 998-4661

AP9625: APC Smart-UPS Two-post Rail Kit SMX039-2: APC Smart-UPS 48V Battery Extension Cable SMX040: APC Smart-UPS 120V Battery Extension Cable Service Bypass Panels SBP1500RM: APC Service Bypass PDU, 120 V; 15 AMP W/ (8) NEMA 5-15R SBP3000RM: APC Service Bypass PDU, 120 V; 30 AMP W/ (4) NEMA 5-20R and (1) L5-30R SBP3000: APC Service Bypass Panel-

Related Documents:

APC Smart-UPS RT 1000 VA 230 V – Marine SURT1000XLIM APC Smart-UPS RT 2000 VA RM 230 V SURT2000RMXLI APC Smart-UPS RT 2000 VA 230 V SURT2000XLI APC Smart-UPS RT 2200 VA 230 V – Marine SURTD2200XLIM APC Smart-UPS RT 3000 VA 230 V with Pre-installed Input/Output Hardwire Kit (See Note below.

offered by Riello UPS, visit the site www.riello-ups.com Our Company is a specialist in the design, development and manufacturing of uninterruptible power supplies (UPS). The UPS described in this manual is a high quality product which has been carefully designed and built in order to guarantee the highest levels of performance.

2 ups.com 1-800-PICK-UPS UPS Services Same Day 1 Day 2 Days Day- Definite Alaska Page Hawaii Page UPS Express Critical * * UPS Next Day Air Early 14 32 UPS Next Day Air 16 34 UPS Next Day Air Saver 18 36 UPS 2nd Day Air A.M. 20 38 UPS 2nd Day Air 22 40 UPS Ground 24 42 UPS Ground - Intra-Alaska 28 N/A UPS Ground - Intra-Oahu N/A 46

2 ups.com 1-800-PICK-UPS Servicios de UPS El Mismo Día 1 Día 2 Días Día Definido Página de Alaska Página de Hawái UPS Express Critical c * UPS Next Day Air Early c 14 32 UPS Next Day Air c 16 34 UPS Next Day Air Saver c 18 36 UPS 2nd Day Air A.M. c 20 38 UPS 2nd Day Air c 22 40 UPS Ground c 24 42 UPS Ground - Dentro de Alaska c 28 N/C UPS Ground .

280 TRANSMISSIONS TRASMISSIONI 230.0014 Vespa PE 200 - Racing 230.0015 Vespa 50 FL/Ape 50 FL 3 230.0016 Vespa 50 FL/Ape 50 FL 230.0017 Vespa 50 FL/Ape 50 FL Racing 230.0010 Ape 50 - Vespa 50/125 230.0011 Minarelli Am6-Aprilia 50 Rs,Rx 230.0012 Derbi Senda - GPR 230.0013 Vespa 50/125 230.0018 Vespa PX 125/150 Racing 6M 230.0019 Yamaha T-Max 500 230.0020 Yamaha T-Max 530 230.0021 Vespa per Kit .

Eleir un Servicio ups.com 1-800-PICK-UPS Servicios de UPS 3 Servicios de UPS 1 Día 2 Días Día Definido Página de Alaska Página de Hawái Paquete - Nacional UPS Next Day Air Early 12 30 UPS Next Day Air 14 32 UPS Next Day Air Saver 16 34 UPS 2nd Day Air A.M. 18 36 UPS 2nd Day Air 20 38 UPS Ground 22 40 UPS Ground - Dentro de Alaska 26 N/C

APC Back-UPS USB USB APC Back-UPS RS USB USB APC Back-UPS LS USB USB APC Back-UPS ES/CyberFort 350 USB APC Back-UPS BF500 USB APC BACK-UPS XS LCD USB APC Smart-UPS USB USB APC Back-UPS 940-0095A/C cables APC Back-UPS 940-0020B/C cables APC Back-UPS 940-0023A cable APC Back-UPS Office 940-0119A cable APC Ba

ASTM STANDARDS IN BUILDING CODES SPECIFICATIONS, TEST METHODS, PRACTICES, CLASSIFICATIONS, TERMINOLOGY VOLUME 1 2007 Forty-fourth Edition ASTM Stock Number: BLDG07 ASTM INTERNATIONAL n 100 BARR HARBOR DRIVE, PO BOX C700, WEST CONSHOHOCKEN, PA 19428-2959 TEL: 610-832-9500 n FAX: 610-832-9555 n EMAIL: service@astm.org n WEBSITE: www.astm.org. Editorial Staff Director: Vernice A. Mayer Editors .