Surge Arresters Rosenberger SLink Surge Arresters - Exlanta

1y ago
14 Views
2 Downloads
959.64 KB
13 Pages
Last View : 15d ago
Last Download : 3m ago
Upload by : Eli Jorgenson
Transcription

Surge Arresters RosenbergerSLink Surge Arresters Rosenberger SLink Surge Arresters Lightning protection components are essential for protecting high- cost radio base stations against over voltages. Coaxial surge arresters from Rosenberger – integrated directly into the cabling system from the antenna down to the base station – safeguard the system and provide reliable deflection in case of over voltages, e. g. by lightning strikes. Effective lightning protection systems deflect over voltages, causing surge currents of 20 kA, resulting in a residual output voltage of only 100 V. Rosenberger offers coaxial surge arresters with N and 7- 16 interfaces, for "non- directed" mounting, with and without gas discharge tubes. Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com 43

Surge Arresters Series 7- 16 RosenbergerSLink Surge Arresters Series 7- 16 Series 7- 16 Wideband Surge Arresters xOrdering Number Version Remarks x60 HS 161- S00 N1 male - male 800- 2500 MHz grounded center contact Assembly Panel Piercing / Packing Unit Instruction PCB Layout 1 76.55 85.2 SW32 SW32 reduced scale x60 HK 561- S00 N1 female - male 800- 2500 MHz grounded center contact 60 X02 B 75 1 86.6 77 21.6 SW32 SW32 reduced scale female - female 800- 2500 MHz grounded center contact 60 X02 B 75 1 88 21.6 77 x60 HK 561- K00 N1 SW32 reduced scale 44 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com

Surge Arresters Series 7- 16 RosenbergerSLink Wideband Surge Arresters - Gas filled Version Remarks x60 BS 161- S00 N1 male - male 800- 2500 MHz discharge tube 90 V included Assembly Panel Piercing / Packing Unit Instruction PCB Layout 1 85.2 89.65 xOrdering Number SW32 SW32 reduced scale female - male 800- 2500 MHz discharge tube 90 V included 60 X02 B 75 1 86.6 21.6 90 x60 BK 561- S00 N1 SW32 SW32 reduced scale female - female 800- 2500 MHz discharge tube 90 V included 60 X02 B 75 1 88 21.6 90 x60 BK 561- K00 N1 SW32 reduced scale x60 BK 531- S00 N1 female - male DC- 2200 MHz discharge tube 350 V included 60 X02 B 75 1 75.6 21.6 SW 32 x60 BK 531- K00 N1 female - female DC- 2200 MHz discharge tube 350 V included 60 X02 B 75 1 77 21.6 SW 32 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com 45

Surge Arresters Series N RosenbergerSLink Surge Arresters Series N Series N Wideband Surge Arresters Version Remarks x53 HS 161- S00 N1 male - male 800- 2500 MHz Assembly Panel Piercing / Packing Unit Instruction PCB Layout 1 88.3 76.45 xOrdering Number reduced scale female - male 800- 2500 MHz 60 X02 B 13 1 91.55 76.45 x53 HK 561- S00 N1 SW19 reduced scale x53 HK 561- K00 N1 female - female 800- 2500 MHz 60 X02 B 13 1 76.45 88 SW19 reduced scale male - female 800- 2500 MHz Grounded center contact B 13 1 99.8 ø 42 x53 HS 501- K00 N1 SW 19 reduced scale female - female 800- 2500 MHz Grounded center contact B 13 1 96.6 ø 42 x53 HK 501- K00 N1 SW 19 reduced scale female - male 2400- 5800 MHz for WiMAX and WLANapplications B 13 1 62.55 39.6 x53 HK 502- S00 N1 SW19 reduced scale 46 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com

Surge Arresters Series N RosenbergerSLink Wideband Surge Arresters - Gas filled Version Remarks x53 BS 161- S00 N1 male - male DC 800- 2500 MHz discharge tube 90 V included Assembly Panel Piercing / Packing Unit Instruction PCB Layout 1 88.3 89.55 xOrdering Number reduced scale female - male DC 800- 2500 MHz discharge tube 90 V included 60 X02 B 13 1 91.55 89.55 x53 BK 561- S00 N1 SW19 reduced scale female - female DC 800- 2500 MHz discharge tube 90 V included 60 X02 B 13 1 88 89.55 x53 BK 561- K00 N1 SW19 reduced scale female - male DC- 2500 MHz discharge tube not included 53MV- A001 B 13 1 66 33 x53 BK 501- S00 N1 SW 19 female - female DC- 2500 MHz discharge tube not included 53MV- A001 B 13 1 57 33 x53 BK 501- K00 N1 SW 19 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com 47

Gas Discharge Tubes RosenbergerSLink Gas Discharge Tubes Gas Discharge Tubes for 7- 16 and N Series Gas Discharge Tube Remarks Packing Unit x53 Z B01- 090 Norm. sparkover voltage 90 V 1 x53 Z B01- 230 Norm. sparkover voltage 230 V 1 x53 Z B01- 350 Norm. sparkover voltage 350 V 1 6 ø8 xOrdering Number 48 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com

Adaptors, Terminations, Attenuators RosenbergerSLink Adaptors, Terminations, Attenuators Rosenberger SLink Adaptors, Terminations, Attenuators For site solution applications, adaptors, terminations and attenuators are available in N and 7- 16 series. The product range includes: Adaptors, straight and right angle adaptors Terminations, male and female, 1 and 20 W Attenuators, 5 and 20 W power rating, from 3 dB to 20 dB attenuation Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com 49

Adaptors RosenbergerSLink Adaptors Adaptors Series 7- 16 Straight Adaptor xOrdering Number Version Remarks Packing Unit x60 S 101- S50 N1 straight 7- 16 male - male 1 54 SW 32 x60 S 101- K50 N1 straight 7- 16 male - female SW 32 SW 32 1 42.5 SW32 straight 7- 16 female - female 1 29 ø 34 x60 K 101- K50 N1 SW32 Right Angle Adaptor Version Remarks Packing Unit x60 S 231- K00 N1 right angle 7- 16 male - female 1 32 34 xOrdering Number SW32 50 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com

Adaptors RosenbergerSLink Adaptors Series N Straight Adaptor xOrdering Number Version Remarks Packing Unit x53 S 101- S00 N5 straight N male - male 1 43 x53 S 101- K00 N5 straight N male - female 1 ø 21 36.4 x53 K 101- K00 N5 straight N female - female 1 ø 16.8 38 Right Angle Adaptor xOrdering Number Version Remarks Packing Unit x53 S 201- K00 N5 right angle N male - female 1 36 24.5 27.9 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com 51

Terminations RosenbergerSLink Terminations Terminations Series 7- 16 Termination 7- 16 male Remarks Return Loss Packing Unit x60 S 17R- 001 N1 1 Watt; Frequency DC - 8 GHz 34.1 dB @ DC to 2 GHz 20 dB @ 2 GHz to 8 GHz 1 x60 S 17R- 020 N1 20 Watt; Frequency DC - 8 GHz 34.1 dB @ DC to 1 GHz 30.7 dB @ 1 GHz to 2 GHz 20 dB @ 2 GHz to 8 GHz 1 41.5 ø 25 xOrdering Number 51 74 SW32 Termination 7- 16 female xOrdering Number Remarks Return Loss Packing Unit x60 K 17R- 001 N1 1 Watt; Frequency DC - 8 GHz 34.1 dB @ DC to 2 GHz 20 dB @ 2 GHz to 8 GHz 1 34.1 dB @ DC to 1 GHz 30.7 dB @ 1 GHz to 2 GHz 20 dB @ 2 GHz to 8 GHz 1 ø 25 43 20 Watt; Frequency DC - 8 GHz 74 51 x60 K 17R- 020 N1 52 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com

Terminations RosenbergerSLink Terminations Series N Termination N male xOrdering Number Remarks Return Loss Packing Unit x53 S 1RR- 001 N3 1 Watt; Frequency DC - 4 GHz 28.3 dB @ DC to 1 GHz 20.8 dB @ 1 GHz to 2.5 GHz 17.7 dB @ 2.5 GHz to 12.4 GHz 1 20.8 dB @ DC to 3 GHz 1 x53 S 15R- 020 N3 20 Watt; Frequency DC - 3 GHz 19.5 51 75 Termination N female xOrdering Number Remarks Return Loss Packing Unit x53 K 1RR- 001 N3 1 Watt; Frequency DC - 4 GHz 23.1 dB @ DC to 4 GHz 1 19.5 20.8 dB @ DC to 3 GHz 1 75 51 20 Watt; Frequency DC - 3 GHz ø 15.7 x53 K 15R- 020 N3 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com 53

Attenuators RosenbergerSLink Attenuators Attenutators Series 7- 16 Attenuators male- female 5 Watt xOrdering Number Return Loss Attenuation Tolerance Power Handling x60 AS 105- K03 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 3 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125 C x60 AS 105- K06 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 6 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125 C x60 AS 105- K10 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 10 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125 C x60 AS 105- K20 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 20 dB 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125 C xOrdering Number Return Loss Attenuation Tolerance Power Handling x60 AS 120- K03 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 3 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125 C x60 AS 120- K06 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 6 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125 C x60 AS 120- K10 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 10 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125 C x60 AS 120- K20 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 20 dB 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125 C xOrdering Number Return Loss Attenuation Tolerance Power Handling x53 AS 105- K03 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 3 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125 C x53 AS 105- K06 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 6 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125 C x53 AS 105- K10 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 10 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125 C x53 AS 105- K20 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 20 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.5 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125 C xOrdering Number Return Loss Attenuation Tolerance Power Handling x53 AS 120- K03 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 3 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125 C x53 AS 120- K06 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 6 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125 C x53 AS 120- K10 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 10 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125 C x53 AS 120- K20 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 20 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.5 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125 C 69 SW32 Attenuators male- female 20 Watt 51 95 SW32 Attenutators Series N Attenuators male- female 5 Watt ø20 ø21 56.5 SW18 Attenuators male- female 54 20 Watt SW18 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84- 18- 499, www.rosenberger.com ø15.7 51 ø21 93

RosenbergerSLinkTM MobileCom Infrastructure Site Solutions Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Tel.: 49 - 86 84 -18 - 0 Fax: 49 - 86 84 -18 - 499 E-Mail: info@rosenberger.de Web: www.rosenberger.com Certified by ISO /TS 16949 . ISO 9001 . ISO 14001 Ordering No. info502SLink/5000/05-2009 pA 143612 05.2009 Rosenberger Production Thewald Kommunikation

RosenbergerSLink 44 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. 49- 86 84- 18- 0, Fax. 49- 86 84-18- 499, www.rosenberger.com Surge Arresters Series 7-16 Surge Arresters Series 7-16Series 7-16 Wideband Surge Arresters xOrdering Number Version Remarks Assembly Instruction Panel Piercing / PCB Layout

Related Documents:

Type 2 surge arresters are tested with a 8/20 ms current wave. Type 3 surge arresters are tested with a 1.2/50 ms and 8/20 ms combined wave. Protection Load protection iPRD, iPRD IT surge arresters Type 2 or 3 LV withdrawable surge arresters Each surge arrester in the range has a specific application: b incoming protection (type 2):

Screw (HEX) Push-Pull Universal Jack NEX10 -5 NEX10 -4 Rosenberger Hochfrequenztechnik GmbH & Co. KG Hauptstraße 1 83413 Fridolfing P.O. Box 1260 84526 Tittmoning Germany Phone 49 8684 18-0 info@rosenberger.com www.rosenberger.com Certified by IATF 16949 · DIN EN 9100 · ISO 9001 · ISO 14001 Order No. pA 397321 · Info530NEX10FlyEN .

Polymer Surge Arresters GE TRANQUELL polymer surge arresters are constructed utilizing a rugged field-proven silicone alloy EPDM housing. Polymer models cover Voltage ratings from 3kV to 228kV. GE TRANQUELL polymer arresters offer exceptional electrical characteristics such as low protective levels, high energy handling

ABB High Voltage Products Surge arresters 3 Surge arrester from ABB Switzerland in Wettingen ABB Switzerland Ltd. produces surge arresters for all applications. This product overview makes it easy to choose the right arrester. We have created a selection table for each of our product groups. In the left hand column of the selection table you will

SURGE ARRESTERS 10 2.1 VARISIL Type HE(-S) product range 10 2.2 VARISIL Type HE(-S) design 10 3 ACCESSORIES FOR VARISIL Type HE(-S) SURGE ARRESTERS 15 3.1 Disconnector or fault indicator 15 3.2 Brackets and terminals 16 3.2.1 Brackets 16 3.2.2 Terminals 16 4 PROCEDURE TO SELECT A VARISIL Type HE(-S) SURGE ARRESTER 17

VariSTAR SURGE ARRESTER Cat. No. Ser. No. Rating MCOV/COV Pres Relief Class Cert. Frequency 50-60 Hz Alt. 0-12000 Ft. 0-3600 M Year Olean, NY USA kV rms kV rms kArms AZG4 63 4/20 kA IEC 60099-4 sym VariSTAR Type AZG4 Surge Arresters Installation and Maintenance Instructions COOPER POWER SRIES Surge Arresters M4 Effective January 2017 .

VariSTAR Type AZG3 Surge Arresters Installation and Maintenance Instructions VariSTAR SURGE ARRESTER Cat. No. Ser. No. Rating MCOV/COV Pres Relief Class Cert. Frequency 50-60 Hz Alt. 0-12000 Ft. 0-3600 M Year Olean, NY USA kV rms kV rms kArms AZG3 63 3/10KA IEC 60099-4 sym COOPER OWER SERIES Surge Arresters MN235013EN Efectie anuary 17 .

300-a02 abp enterprise sdn bhd. 7th floor menara lien hee no, 8 jalan tangung, 47700 petaling jaya. selangor p. j john c.o.d. 03-7804448 03-7804444 300-c01 control manufacturing 400-2 (tingkat satu) batu 1/2, jalan pahang, 51000 kuala lumpur kl lal net 60 days 03-6632599 03-6632588