GE Fanuc fanuc/rx3i-pacsystem/IC695PSA040Rx3i PacSystemRX3I Power supply 120/240VAC and 125VDC 40 watts occupies twoslots on system base. IC695P IC695PS IC695PSA919-535-3180sales@pdfsupply.com

4Power Supply, 120/240 VAC or 125 VDC, 40 Watt: IC695PSA040Power Supply IC695PSA040 is a 40-Watt supplythat operates from an input voltage source in therange of 85 to 264 VAC or 100 VDC to 300 VDC.POWERThis power supply provides three outputs:P/S FAULT 5.1 VDC output,OVERLOAD 24 VDC relay output that can be used topower circuits on Output Relay modules. 3.3 VDC. This output is used internally byRX3i modules with IC695 catalog numbers.OVERTEMPPower Supply40W ACCautionOnly one IC695PSA040 can be used in aPACSystems RX3i (IC695 catalog number)Universal Backplane. This Power Supply cannot beused with other RX3i power supplies in redundantor increased capacity modes. Power Supplyversion IC695PSA040C and before may causeequipment damage if inadvertently installed in thesame backplane as another RX3i power supply.If the number of modules required exceeds thecapacity of the Power Supply, the additionalmodules must be installed in Expansion or Remotebackplanes.PACSystems RX3iThe Power Supply indicates when an internal faultoccurs so the CPU can detect loss of power or logthe appropriate fault code.GFK-2314CChapter 4 Power Supplies4-11

4LEDsFour LEDs on the Power Supply indicate: PO W ERPower (Green/Amber). When this LED isgreen, it indicates power is being suppliedto the backplane. When this LED is amber,power is applied to the Power Supply butthe Power Supply switch is off.P/S F AUL TOV E RT E MPOV E RL O ADP/S Fault (Red). When this LED is lit, itindicates the Power Supply has failed andis no longer supplying sufficient voltage tothe backplane.ONOFFINPUT120/240 VAC 125 VDCOver Temperature (Amber). When this LEDis lit, it indicates the Power Supply is nearor exceeding its maximum operatingtemperature.Overload (Amber). When this LED is lit, itindicates the Power Supply is near orexceeding its maximum output capability onat least one of its outputs.The CPU Fault Table shows a fault if anyOvertemperature, Overload, or P/S Faultoccurs.PSA04050/60 HZ 70 WWIRE AWG# 14-22TORQUE 4.4 in-lb(0.5 N-m)75 DEG. C COPPERCONDUCTORS ONLY L1 L1WARNING:EXPLOSION HAZARD –WHEN IN HAZARDOUSLOCATIONS, TURN OFFPOWER BEFOREREPLACING OR WIRINGMODULES.N/- L2N/- L2On/Off SwitchThe ON/OFF switch is located behind the dooron the front of the module. The switch controlsthe operation of the outputs of the supply. Itdoes NOT interrupt line power. Projecting tabsnext to the switch help prevent accidentallyturning it on or off.Wiring TerminalsTerminals for power, ground, and MOVdisconnect accept individual 14 to 22 AWGwires.4-12PACSystems RX3i System Manual – October 2005GFK-2314C

4Specifications: IC695PSA040Nominal Rated VoltageInput Voltage RangeACDC120/240 VAC or 125 VDC85 to 264 VAC100 to 300 VDCInput Power(Maximum with Full Load)70 Watts maximumInrush Current4 Amps, 250 milliseconds maximum *Output Power40 Watts maximum total5.1 VDC 30 Watts maximum3.3 VDC 30 Watts maximumThe maximum total output power available depends onthe ambient temperature, as shown.Output Voltage24 VDC: 19.2 VDC to 28.8 VDC5.1 VDC: 5.0 VDC to 5.2 VDC (5.1 VDC nominal)3.3 VDC: 3.1 VDC to 3.5 VDC (3.3 VDC nominal)Output Current24 VDC: 0 to 1.6 Amps5.1 VDC: 0 to 6 Amps3.3 VDC: 0 to 9 AmpsIsolation (input tobackplane):250 VAC continuous; 1500 VAC for 1 minuteRipple (all outputs)150 mVNoise (all outputs)150 mVRide-through time20 ms. This is the length of time the Power Supplymaintains valid outputs if the power source isinterruptedWiring TerminalsEach terminal accepts one 14 AWG to 22 AWG wire.Current per Terminal6 AmpsNumber of Daisy-ChainedPSA040 SuppliesUp to 4* The Inrush Current specification is given as a guide for sizing the external powersource for the IC695PSA040. Peak inrush current may be higher for shorter durations.WarningThe power supply’s door must be closed. During normal operation with an ACpower source either 120 VAC or 240 VAC is present on the AC Power Supply. Thedoor protects against accidental shock hazard that could cause severe or fatal injuryto personnel.GFK-2314CChapter 4 Power Supplies4-13

4Thermal DeratingsThe maximum output power for Power Supply PSA040 depends on the ambient temperature, asshown below. Full output power is available up to at least 32 C (89.6 F).Power (W)5V Fully re (C)3.3V5VTotalPower (W)3.3V Fully Loaded454035302520151050010203040Temperature (C)3.3V4-14PACSystems RX3i System Manual – October 20055VTotalGFK-2314C

4Overcurrent ProtectionThe 5.1 VDC output is electronically limited to 7 Amps. The 3.3 VDC output is limited to 10Amps. If an overload (including short circuits) occurs, it is sensed internally and the PowerSupply shuts down. The Power Supply continually tries to restart until the overload condition isremoved. An internal, non-repairable, fuse in the input line is provided as a backup. The PowerSupply usually shuts down before the fuse blows. The fuse also protects against internal supplyfaults The CPU Fault Table shows a fault if any Overtemperature, Overload, or P/S Faultoccurs. There is no additional indication if the Power Supply fuse blowsField Wiring: IC695PSA040Power Source and Ground ConnectionsThe wires from the power source and groundconnect to the terminals on the Power Supply asshown at right. Each terminal accepts one AWG14 to AWG 22 wire. L1To additionalunits L1N/- L2N/To additionalunits- L2WarningIf the same external AC power source is used toprovide power to two or more RX3i power supplies inthe system, connection polarity must be identical ateach power supply. A resulting difference in potentialcan injure personnel or cause damage to equipment.Also, each backplane must be connected to acommon system ground.Keep as short aspossible. Connectdirectly tomounting panel.Input Overvoltage ProtectionThe bottom terminal is normally connected toframe ground with a user-installed jumper asshown lower right. If overvoltage protection isnot required or is supplied upstream, no jumperis needed.To Hi-pot test this supply, overvoltage protectionmust be disabled during the test by removing thejumper. Re-enable overvoltage protection aftertesting by reinstalling the jumper. / L1- / N / L2Jumper strapconnectsovervoltageprotectiondevices toframe groundFrameGroundScrewTerminalsIn systems with a floating neutral input (the neutral line is not referenced to Protective EarthGround), this jumper must NOT be installed. In addition, in a floating neutral system, voltagesurge protection devices such as MOVs must be installed from L1 to earth ground, and from L2(Neutral) to earth ground.GFK-2314CChapter 4 Power Supplies4-15

GE Fanuc Manuals Series 90-70 9070 GFK-2055 Author: 1-919-535-3292 Subject: IC697VSC096 Single Board Computer Created Date: 4/29/2014 10:08:26 AM .

Related Documents:

FANUC Series 0–MC FS0–MC Servo Amplifier Module SVM FANUC Series 15 FS15 Spindle Amplifier Module SPM FANUC Series 16 FS16 FANUC Series 18 FS18 FANUC Series 20 FS20 FANUC Series 21 FS21 FANUC Power Mate MODEL D PM–D FANUC Power Mate MODEL F PM–F In this manual, the servo parameter number is explained as shown below. (Example) 1877 8X62

fanuc ac servo motor βis series descriptions b-65302en fanuc ac servo motor αis/αi/βis series parameter manual b-65270en fanuc ac spindle motor αi series descriptions b-65272en fanuc ac spindle motor βis series descriptions b-65312en fanuc ac spindle motor αi/βi series parameter manual b-65270en fanuc servo amplifier αi .

FANUC:A04B-0234-C222 Pendant Box for B, C, iA, iB, iC. FANUC:A04B-0281-K020 Bolt Set Includes iE. FANUC:A04B-0311-5026#HGP Grease Gun. FANUC:A04B-0313-J023#COM Vertical Wire Alignment Block iA,iB,iC,iD,iE, CiA. FANUC:A04B-0325-J095#FIN DI/DO Unit for CiA-400&600 . FANUC:A06B-0114-B103 Servo Motor C3 Axis. FANUC:A06B-6117-H302 Servo Amp .

fanuc ac spindle motor αseries parameter manual b-65160e fanuc servo motor β series descriptions b-65232en fanuc servo motor β series maintenance manual b-65235en fanuc servo motor β series maintenance manual (i/o link option) b-65245en. b-63323en-1/03 table of contents (volume 1 of 3)

B-64120EN/01 PREFACE p-1 PREFACE The models covered by this manual, and their abbreviations are : Model name Abbreviation FANUC Series 0i -TC 0i-TC FANUC Series 0i -MC 0i-MC Series 0i-C 0i FANUC Series 0i Mate -TC 0i Mate -TC FANUC Series 0i Mate -MC 0i Mate -MC Series 0i Mate -C 0i Mate NOTE

For specifications and maintenance of FANUC CONTROL MOTOR α series, refer to the following manuals : Document name Document number Major contents Major usage FANUC AC SERVO MOTOR α series DESCRIPTIONS B-65142E Specification Characteristics External dimensions Connections Selection of motor FANUC AC SPINDLE MOTOR α series DESCRIPTIONS B .

FANUC Power Mate–MODEL F Power Mate–F Power Mate The table below lists manuals related to the Power Mate–D/F. In the table, this manual is marked with an asterisk(*). 1 Manuals related to the Power Mate–D/F Manual name Specification Number FANUC Power Mate–MODEL D/F DESCRIPTIONS B–62092E FANUC Power Mate–MODEL D/F CONNECTION .

fanuc cnc (new 2000) tshudin # pl-45 cnc cylindrical grinder w/ fanuc cnc (new 2004) micron # mfn-350-rdt cnc centerless grinder w/ fanuc cnc okamoto # acc-1224-ex 12”x . miyano # lz-oir cnc lathe w/ fanuc cnc miyano # bnd-42s2 cnc lathe w/ lns bar-feed & fanuc cnc