3500/33E 16-Channel Relay Module - Amazon S3

3y ago
26 Views
2 Downloads
204.27 KB
5 Pages
Last View : 26d ago
Last Download : 3m ago
Upload by : Nora Drum
Transcription

3500/33E 16-Channel Relay ModuleBently Nevada* Asset Condition MonitoringDescriptionThe 16-Channel Relay Module is a full-height module that provides 16 relayoutputs. Any number of 16-Channel Relay Modules can be placed in any of theslots to the right of the Transient Data Interface Module. Each output of the 16Channel Relay Module can be independently programmed to perform neededvoting logic.Each relay utilized on the 16-Channel Relay Module includes "Alarm Drive Logic".Programming for the Alarm Drive Logic uses AND and OR logic, and can usealarming inputs (Alert and Danger statuses), Not- OK, or individual PPLs fromany monitor channel or any combination of monitor channels in the rack. Usersprogram this Alarm Drive using the 3500 Rack Configuration Software to meetthe specific needs of the application.Specifications and Ordering InformationPart Number 100M5818-01Rev. NC (04/13)Page 1 of 5

SpecificationsStorageTemperature:Inputs-40 C to 85 CPowerConsumption:(-40 F to 185 F).5.8 watts typical.OutputsHumidity:95%, non-condensing.Compliance and CertificationsOK LED:Illuminated when module isfunctioning properly.TX/RX LED:Transmit and Receive. Flashes toindicate proper communicationsbetween this module and othermodules within the rack.CH ALARM LED:Illuminated to indicate that theRelay Channel is in an alarmstate.RelaysType:Single-pole, double-throw (SPDT)relays.EnvironmentalSealingEMCStandards:EN 61326-1:2006Emissions and ImmunityEuropean Community Directives:EMC Directive 2004/108/ECElectrical SafetyStandards:EN 61010-1: 2010European Community Directive:2006/95/EC Low VoltageFor further certification and approvals information please visit thefollowing website:www.ge-mcs.com/bentlyHazardous Area ApprovalsNorth AmericanEpoxy-sealed.Arc Suppressor250 Vrms, installed as standard.Contact Life100,000 cycles @ 5 A, 24 Vdc or240 Vac.Approval Option(01)Class I, Div 2Groups A, B, C, DT4 @ Ta -0 C to 65 C(32 F to 150 F)OperationFour groups of four channels areswitch selectable for NormallyDe-energized or NormallyEnergized.Environmental LimitsOperatingTemperature:-30 C to 65 C(-22 F to 150 F).Specifications and Ordering InformationPart Number 100M5818-01Rev. NC (04/13)Page 2 of 5

Application AdvisoryContact Ratings for Standard SystemsStandard Relays(Resistive load):Max switchedVoltage:dc: 300Vac: 250VMax switchedcurrent:dc: 5Aac: 5AMax switchedVA:Due to the potential for varying voltage levels,please review the following:It is possible to connect field wiring to the3500/33E relays such that conductors areexposed to potential human contact. This couldpresent a shock hazard at high voltages.Customers who wish to use the 3500/33Erelays at higher voltages up to 300 Vdc shouldbe advised that the hardware is perfectlycapable of handling this voltage but thatappropriate safety precautions should betaken with respect to the shock hazard. Note:maximum allowable power (P) is restricted to120W. Voltage (V) and/or current (I) must notexceed this limit. (P IV)Rack Space Requirementsdc: 150VAac: 1500VAMin switchedCurrent:Main Module:1 full-height front slot.I/O Modules:1 full-height rear slot.dc: 100mA / 12VOrdering ConsiderationsThe 3500/33E requires 3500 RackConfiguration software, version 4.6 or later.PhysicalMain Module:Ordering InformationDimensions(Height x Widthx Depth):235 mm x 44.5 mm x 292 mm3500E 16-Channel Relay Module3500/33E -AXX-BXX(9.25 in. x 1.75 in. x 11.5 in).A: Output Module1.16 kg (2.55 lb).B: Agency Approval Option00None01CSA/NRTL/C (Class 1, Div 2)Weight:I/O Module:Dimensions(Height x Widthx Depth):0116-Channel Relay OutputModuleSpares100M2197-01Spare 16-Channel Relay ControlModule209.5 mm x 44.5 mm x 152.4 mm(8.25 in. x 1.75 in. x 6 in).100M2196-01Spare 16-Channel Relay OutputModuleWeight:0.86 kg (1.9 lb).04425545Grounding Wrist Strap (single use)Specifications and Ordering InformationPart Number 100M5818-01Rev. NC (04/13)Page 3 of 5

100M3283-0116-Channel Relay Module Manual177440Connector Header, InternalTermination, 16-position, GreenSpecifications and Ordering InformationPart Number 100M5818-01Rev. NC (04/13)Page 4 of 5

Graphs and FiguresFigure 1: Front and rear view of the 16-Channel Relay Module1.Relay module2.I/O module3.Status LEDs4.Relay channel LEDs5. Relay mode selection switch* Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company. 2013 Bently Nevada, Inc. All rights reserved.Printed in USA. Uncontrolled when transmitted electronically.1631 Bently Parkway South, Minden, Nevada USA 89423Phone: 775.782.3611Fax: 775.215.2873www.ge-mcs.com/bentlySpecifications and Ordering InformationPart Number 100M5818-01Rev. NC (04/13)Page 5 of 5

Bently Nevada * Asset Condition Monitoring 3500/33E 16-Channel Relay Module . Description . The 16-Channel Relay Module is a full-height module that provides 16 relay outputs. Any number of 16-Channel Relay Modules can be placed in any of the slots to the right of the Transient Data Interface Module. Each output of the 16-

Related Documents:

Nissan Micra - OWM 4734 Nissan Micra - OWM 4734 CPU E6 H33750 1 Battery 2 Ignition switch 3 Fusible link holder 4 Fuse box 5 Fuse and relay box a) accessory relay b) blower motor relay 6 Intelligent power distribution module a) starter relay b) cooling fan hi relay c) cooling fan lo relay d) fuel pump relay e) ignition relay f) ECM relay

Maserati- 3500 GT Coupe Touring- Engine 9 Maserati- 3500 GT Coupe Touring- Exhaust 11 Maserati- 3500 GT Coupe Touring- Fuel System 12 Maserati- 3500 GT Coupe Touring- Glass and Seals 13 Maserati- 3500 GT Coupe Touring- Interior 18 Maserati- 3500 GT Coupe Touring- Lights 20 Maserati- 3500 GT Coupe Touring- Luggage Compartment 22

38 - Check voltage output to fuel pump @ relay set 39 - Check voltage input to relay set from ignition switch 40 - Check voltage input to fuel pump relay of relay set 41 - Check input voltage to control relay of relay set 42 - Check input voltage to control relay of relay set (continued)

3500/61E & 3500/67E Temperature Monitor . Bently Nevada* Asset Condition Monitoring . 3300/35 6. with the I/O modules used for the 3300/36 2. Description . The 3500/61E and 3500/67E modules provide six channels and two channel of temperature monitoring. Both monitors can be ordered to accept Resis tance

125 crf125f/fb je03e 3500 3500 3500 3500 3500 trx250tm/te te21e, te48e 3250 3250 3250 3250 150 CRF150F KE02E 4250 4250 4250 4250 400 TRX400X TE23E 3500 CRF150R*/ RB* KE03E 6250 6250 6250 6250 6250 420 TRX420FA/FPA TE37E 3250

Bently Nevada* Asset Condition Monitoring 3500/05 System Rack . Description . The 3500 System rack design holds all 3500 monitor modules and rack power supplies. It allows the various 3500 modules to communicate with one another and the power supplies to distribute power to each mod ule as required. 3500 Racks are available in two sizes: 1.

Catalyst 3500 XL Cisco Cisco Catalyst 3500 XL 2900 XL Catalyst 1900 & &' IP 380 &' Gigabit Ethernet&' &' Catalyst 3500 XL&' Cisco IOS( Cisco Visual Switch Manager (CVSM) &' Web Cata-lyst 3500 XL&' * &' * 802.1Q ISL VLAN TACACS Uplink Fast Catalyst 3500 XL 3 Cisco GigaStack( Gigbit Interface Converter (GBIC)

ASTM C 1702 – Heat of hydration using isothermal calorimetry Heat of Hydration. is the single largest use of isothermal calorimetry in the North American Cement industry Other major applications include . Sulfate optimization . and . admixture compatibility Several Round Robins in North America and Europe on Heat of Hydration .