LED hazardous lightingcatalog

AreaLinearEmergencyFlood2 Hazlux Lighting US Brochure

Hazlux Table of contents1Area lighting2Linear lighting3Emergency lighting4Flood lightingUS Catalog Hazlux Lighting 3

4 Hazlux Lighting US Brochure

OverviewQuality productsThomas & Betts is committed todelivering high-quality industrial lightingfixtures designed, tested and certifiedfor use in hazardous locations andadverse environment conditions.You can rely on Hazlux to safely providelight where you need it — even underthe harshest indoor and outdoorconditions. If safety, labor reduction,quality and reliability are your priorities,consider Hazlux lighting products.Features & benefits Nameplate displays third-party certification for all electricaland hazardous location ratings as required by NEMA,OSHA regulations and CSA. This allows for peace ofmind, confirming, the right lighting fixture is installed in acertified condition. Cast, copper-free aluminum construction for high strength,light weight and corrosion resistance. Meets the highestlife expectancy you can expect from a lighting fixture in aparticular application. The paint used in our standard finish is baked, electrodeposited, pure epoxy powder for maximum corrosionprotection. Additional paint finishes are available, offeringincreased protection against harsh environments. All exposed hardware is corrosion-resistant stainless steel,which will limit and ease maintenance required on thelighting fixture. Simple hinge arrangement permits “hands-free” wiring for afaster and easier installation.US Catalog Hazlux Lighting 5

OverviewHazardous locationsHazardous location — An area where the possibility of explosion and fire is created bythe presence of flammable gases, vapors, dust, fibers or flyings.Class I - GasClass I - Class I locations are those in which flammable gases,flammable liquid-produced vapors or combustible liquid-producedvapors are or may be present in the air in quantities sufficient toproduce explosive or ignitable mixtures.Divisions vs. zones: area classificationContinuoushazardousZone 0ContinuoushazardousZone 1Division 1ContinuoushazardousZone 2Division 2Note: These are simplified definitions - complete data is in the Canadian Electicral Code (C.E.C)Typical class I locations: Petroleum refineries and gasoline storage and dispensingareas Industrial firms that use flammable liquids in dip tanks forparts cleaning or other operations Petrochemical companies that manufacture chemicals fromgas and oil Dry cleaning plants where vapors from cleaning fluids canbe present Companies that have spraying areas where they coat pro ducts with paint or plastics Aircraft hangars and fuel serving areas Utility gas plants and operations involving storage andhandling of liquified petroleum gas or natural gasClass III - FibersClass III - Class III locations are those that are hazardousbecause of the presence of easily ignitable fibers or wherematerials producing combustible flyings are handled,manufactured or used, but in which such fibers/flyings are notlikely to be in suspension in the air in quantities sufficient toproduce ignitable mixtures.Typical class III locations: Textile mills, cotton gins, cotton seed mills and flaxprocessing plants Any plant that shapes, pulverizes or cuts wood and createssawdust or flyingsNote: Fibers and flyings are not likely to be suspended in the air but can collect aroundClass II - DustClass II - Class II locations are those that are hazardous becauseof the presence of combustible dust.Typical class II locations: Grain elevators, flour and feed mills Plants that manufacture, use or store magnesium oraluminum powders Plants that have chemical or metallurgical processes:producers of plastics, medicines and fireworks, etc. Producers of starch or candies Spice-grinding plants, sugar plants and cocoa plants Coal preparation plants and other carbon handling orprocessing areasmachinery or on lighting fixtures and a spark or hot metal can ignite them.Division 1 - Normally hazardousDivision 1 - Hazardous gases or dusts are present undernormal operation conditions or during frequent repair andmaintenance activity.Groups A, B, C, DGroups A, B, C and D - The gases and vapors of class Ilocations are broken into four groups by the code A, B, C andD. These materials are grouped according to the ignitiontemperature of the substance, its explosion pressure and otherflammable characteristics.Groups E, F, GGroups E, F, G - Class II dust locations groups E, F and Gare classified according to the ignition temperature and theconductivity of the hazardous substance.Division 2 - Not normally hazardousDivision 2 - Hazardous gases or dusts are not present undernormal operating conditions.6 Hazlux Lighting US Brochure

Four step method for selecting lightingfixtures for hazardous locations.1. Select a fixture that meets your class, division and grouprequirements, for example: Class I, division 2, group D Class II, division 1, group G2. Determine the t-number for your selected fixture.Be sure it is for the specific wattage, ballast housing,optical assembly and ambient temperature. Use the published information in this catalog or in Hazlux product brochures3. Determine the maximum allowable temperature for thehazardous materials involved.Class I gas: Ignition temperature for the specific gas (from NFPA497M)Class II dust: Group E - 200 C Group F - 200 C Group G - 165 C Or ignition temperature of dust if lower Above from NEC table 500-3(F)4. Compare the t-number (from Step 2) to maximum allowabletemperature (from Step 3). If t-number is cooler than the maximum allowabletemperature, the selected fixture is suitable. If t-number is hotter than the maximum allowabletemperature, the selected fixture is not suitable.Divisions vs. zones: area classificationClass I, II, div. 1, 2 t-numberT1T2T2AT2BT2CT2DT3T3AT3BT3CT4T4AT5T6Max. temperature450 ºC300 ºC280 ºC260 ºC230 ºC215 ºC200 ºC180 ºC165 ºC160 ºC135 ºC120 ºC100 ºC85 ºCUS Catalog Hazlux Lighting 7

OverviewHazlux applications From an offshore oil rig in the Atlantic Ocean to the factory floor, there’s a Hazlux lightingfixture to stand up to virtually every hazardous location.Here are some of the places you’ll find Hazlux fixtures: Chemical manufacturing and processing plants Oil refineries Oil drilling rigs Offshore platforms Pipeline pumping stations Pulp and paper plants Aluminum and copper smelting Steel mills and foundries Mining operations Grain handling facilities Flour, sugar and starch processing Food processing plantsPaint and rubber manufacturing facilitiesMarine and coastal facilitiesShipyards and shipbuilding plantsPower generation plantsWaste treatment facilitiesPaint, chemical and plastic mixing/storage areasBulk truck terminalsSolvent/cleaning areasHazlux lighting fixtures are built to withstand the harsh environmental conditions that exist in real settings.1 Hose Down 2 Vibration 3 High Ambient 4 Dust 5 Corrosion 6 Marine 7 Ice 8 Wind123456788 Hazlux Lighting US Brochure

Hose-down and wet locations Certified for wet locations—NEMA 4X, IP66 (indoor andoutdoor); UL 1598A (marine) and CSA listed Superior gasketing system—both tank and globe gasketingsystems withstand hose-down pressures Uninterrupted globe thread—assures positive seal Baked-on, dry epoxy coating—not paint but 100% dry solid Globes, refractors and finish designed to withstand thermalshock during hose downHigh-ambient temperature areas All standard fixtures are tested and listed for at least 40 Cambient - even under heavy dust blanket and no air flow Exclusive heat sink design results in a cool operating fixture,extended driver/module life and lower maintenance costs Unmatched selection of high-ambient, temperature ratedfixtures—contact factory for fixtures certified for 55 C Steam spray and thermal shock resistantCorrosion and abrasion Baked-on, dry epoxy coating—not paint but 100% drysolids— Stainless steel external hardware Sand-blast resistant finish Superior silicone gasketing system on both tank and globe. Aluminum components contain less than 0.4% copper—maximum corrosion resistance Special HazCote corrosion fighter finish available forextremely corrosive areas; consult your Thomas & Bettssales representative for detailsIce and arctic conditions Gasketing system and finish allow for expansion andcontraction through wide temperature variations High-strength mechanical mountings withstand extra iceloading Tempered glassware available for extra thermal shocksafety marginVibration, seismic shock and vandalism Vibration tested by UL and CSA Vibration-resistant hardware throughout fixture Screw retainers on guard ensure retention even if screwsare not completely tightened Vibration-resistant globe thread and sealing system Optional refractors, high-strength tempered glass andsilicon coated globes for protection from vandalismDust blanket Tested and listed by UL and CSA Thermal performance is at 40 C ambient; optional thermalperformance to 55 C (consult factory) Cone pendant mount available (45 sloped sides) for areaswhere dust or other residue buildup is a problem Exclusive heat sink design—results in a cool operatingfixture, extended driver/module life and lowermaintenance costsMarine-duty rating This feature is supplied as standard on mostHazlux 3 fixtures Designed for abuse—hose down, arctic, hurricane,vibration and shock, high temperature, corrosion and otherenvironmental conditions typical of adverse marine locations Exclusive combination of marine and hazardous locationapprovals on the same fixture lineWind Wind-tunnel tested at McDonnell Douglas Corporation atair flow speeds in excess of 198 mph (320 km/h) Guard specially designed to secure reflector during highwind loading All fasteners are stainless steel High-strength mechanical mountings withstand strongwind loadsUS Catalog Hazlux Lighting 9

110 Hazlux Lighting US Brochure

Area lightingHazlux 3 series 1Safe, durable, and now available with LEDtechnology for superior energy efficiency,Thomas & Betts Hazlux products are the brandspecifiers rely on to safely provide light where it’sneeded — even under the harshest indoor andoutdoor conditions. The Hazlux 3 LED seriesoffers longer life, enhanced energy efficiency,reduced maintenance and a smaller footprint.All Hazlux LED products are designed andassembled for exceptional service and supportwith reduced lead times. Experienced assemblyoperation easily accommodates both large andsmall production runs with a fast turnaround.Maintenance-friendly Field-replaceable LED engine and driverLED fixtures with superior technology and performance High lumens per watt ratio Higher t-ratings for cooler operation and extended LED and driver lifein extreme temperatures Available with a thermal-resistant globe and a variety of field—changeable internal and external reflectors for the ideal beam angleLabor-saving installation Designed for easy retrofit installation with existing Hazlux 3 top-hats Hinged design for single-person installation Oil & gasMiningFood & beverageChemical industriesAdvantages Easy tank access allows for safe, quickmaintenance of Hazlux lighting fixtures The Hazlux LED fixtures engine and driver aredesigned for easy field replacement Cast, copper-free aluminum constructionand epoxy paint provides the highest level ofcorrosion resistanceApplicationsUS Catalog Hazlux Lighting 11

Area lightingHazlux 3 LED DL-series 1HazVertor adapter ringReplace competitor fixtures without removing the top hatThe HazVertor adapter ring offers the freedom to replace Champ Seriesby Crouse-Hinds lighting fixtures (VMV, DMV or LMV types) with Hazlux3 lighting fixtures without removing the Crouse-Hinds top hat from theconduit system, eliminating the need to replace conduit and wiring.Save time and increase efficiency.The HazVertor ring can be ordered as a separate item or as part of aHazlux 3 fixture assembly. Look for the HV1 mounting style options andswitch to increased efficiency, wider suitability for hazardous locations,improved light distribution and improved t-numbers.HazVertor adapter ringHazlux UNIPAK packaging UNIPAK is the Hazlux customized packaging systemdesigned to save money UNIPAK fixtures are easily assembled and can includeglobes, guards, reflectors, lamps, fuses and other options Outlet boxes are shipped separately; consult factoryregarding outlet boxes to be assembled toUNIPAK fixtures Assembled UNIPAK fixtures are shipped in one cartonwith the fixture foam packed in place For ordering information, refer to the “catalog numberingsystem” for each individual Hazlux fixture series UNIPAK saves seven ways: Reduces the number of cartons to receive,count, move, open and dispose Reduces storage issues Reduces inventory expense Eliminates lost or back-ordered parts Significantly reduces labor costs Reduces total installed cost per fixtureCertifications and standardsClass I Division 2, groups A, B, C and D UL listed (UL file # E65285) Wet location Marine location on classifiedContact your Thomas & Betts sales representative to verify classification.Note: Crouse-Hinds and Champ are registered trademarks of Cooper Technologies Company, owned by Eaton.12 Hazlux Lighting US Brochure

1Hazlux durability meets LED technology High-efficacy fixtures offer excellent performanceand energy savingsThomas & Betts has taken the rugged, reliable design ofHazlux lighting fixtures and introduced the capabilities ofLED technology to create a high-performance fixture withan impressive lumen output.Higher t-ratings and optimal thermal managementextend LED and driver life expectancyWith an exclusive design that maximizes heat dissipation,Hazlux LED fixtures lower internal temperature and allow forbetter T-ratings which means extended LED and driver life inextreme ambient temperatures.With the entire surface acting as a heat sink, Hazlux LEDluminaires allow higher wattages for better performance.Hazlux modelAC power 20,400123Ambient temp. 40 CHazlux modelClass Idiv 2Class Idiv 2& class IIDL005T5T4AAmbient temp. 55 CClass I div 2Class I div 2& class ADL017T4T3CN/AN/ADL020T3CT3CN/AN/AVersatile optics include internal reflector optionsfor diffused light distributionHazlux LED fixtures are available with a thermal-resistantglobe and a variety of external and field-changeable internalreflectors for the ideal beam angle from 35 to 65 for yourspecific applications.Internal reflectorInternal reflector (actual application)Note: only for models DL005, DL007 and DL010LED single boardLED single board with internal reflector installedUS Catalog Hazlux Lighting 13

Area LightingHazlux 3 series 1Labor-saving installationand maintenance-friendly construction.Designed for easy retrofit installationUsing the same mounting style options as existing Hazlux lighting fixtures, the newLED luminaires can easily be attached as retrofit fixtures.The HazVertor adapter ring makes it easy to replace Crouse-Hinds Champ series lighting fixtures without removing the top hat from the conduit system.Hinged design for hands-free wiringEasy tank access allows Hazlux lighting fixtures to be maintained quickly and safely.The hinged lid is designed to support the weight of the tank, leaving both theinstaller’s hands free.Field-replaceable LED engine and driverThe LED driver is designed in its own compartment so it can be easily replaced inthe field using a connector, with no re-wiring required. A fiberglass insulator protectsthe driver from the heat of the LED engine.Robust construction for long life expectancyCast, copper-free aluminum construction offers corrosion resistance in a strong,lightweight fixture for maximum life expectancy. Baked epoxy powder finishes andstainless steel exposed hardware provide additional corrosion resistance.Certifications shown on external surfaceAn easily identifiable nameplate displays third party certification for all electrical andhazardous location ratings as required by the NEMA, OSHA regulations and CSA toprovide peace of mind, confirming that the correct lighting fixture with the requiredcertifications is in place.Now listed on the 'Design Lights Consortium' Qualified Products ListThe Hazlux DL Series is now listed on the Qualified Products List (QPL) of theDesign Lights Consortium (DLC) which is an institution devoted to definingand promoting leading-edge, high-quality, and high-efficiency LED products.Note: Crouse-Hinds and Champ are registered trademarks of Cooper Technologies Company, owned by Eaton.14 Hazlux Lighting US Brochure

1Assembly guideComplete luminaire consists of:– A mounting style– Driver tank– Globe or refractor– Optional guard and/or reflectorHazlux 3 LED DL series - assembly guideMounting styleCone-top pendantCeiling andpendant mountHazVertor adapter ringWall mount25 AnglestanchionStraight stanchionDriver tankStandard housingGlobe or refractorRefractor globeHeat-resistantprismatic glassGuardPolymeric guardCast guardReflector*30º Angle reflectorStandard dome*Reflectors are sold separatelyUS Catalog Hazlux Lighting 15

Area LightingHazlux 3 series 1Catalog numbering systemLED driver tankOptics and mountingsDLØ10EUNØ123456-OptionsLabelingTGC- C2 -ETI6U78910111213Hazlux DLseries modelEquivalentHID luminareDL005100WDL007175WDL010250WDL015400WNote: For reference onlyLED driver tankOptics and mountings1 Fixture seriesDLHazlux 3 LED series2 FixtureØStandard fixture3 Lumen output055,800 Lumens, 45W †074 Driver circuit10,100 Lumens, 88W†1515,600 Lumens, 122W†1717,800 Lumens, 131W†2020,400 Lumens, 166W†5 Voltage/frequency UNOrder assemblyoptions**7,100 Lumens, 58W†10E7Electronic LED driver89Guard optionFixture120 to 277VAC 50/60Hz(voltage range includes 208V, 220V, 240V etc.)†UN2 Universal 347/480VAC 50/60Hz(Not available for DL017 and DL020) †6 LED driverhousing styleØStandard housing†SStandard housing with stainless steel insertCertifications and standardsClass I Division 2, groups A, B, C and D Zone 2, Group IIC, IIB and IIAThermal & heat-resistant prismatic glassglobe†R1Type I glass refractor globeR3Type III glass refractor globeR5Type V glass refractor globeBlank No guard†CCast aluminum guardLPolymeric guardA2¾" Cone-top pendant†A31" Cone-top pendant†B2¾" Wall mountB31" Wall mountC2¾" Ceiling mount†C31" Ceiling mount†HV1HazVertor ring class I div. 2 zone 2***†L411 4" Straight stanchionL511 2" Straight stanchionS411 4" 25 Angle stanchionS511 2" 25 Angle stanchionBlank No mounting (to replace existing fixture)Class II Division 1 and 2, groups E, F and G10 UNIPAK optionClass IIITGEUNIPAK with LED light sourceTHazCote custom anti-corrosion coating†GGray color option†l3Internal reflector 35 beam angle*l4Internal reflector 45 beam angle*l6Internal reflector 65 beam angle* UL 1598 A for Marine Locations NEMA 4X UL 844Options11 Special options CSA C22.2 No. 137.0Contact your Thomas & Betts sales representative to verify classification.Simultaneous Class I Division 2 and Class II12 Light distributionoptionsCertifications & Labeling13 Rating labelULabeled for shipment to the United States* DL005, DL007 and DL010 only** For silicone coating, please add the suffix "s" before the first digit (ex. STG)*** Not for use with HPM2 or JM5 mounts†16 Hazlux Lighting US BrochureOption includes DLC Qualified Products Listing. Contact Thomas & Betts TechnicalService to verify classification.

1Individual components (to be used with LED driver housing)Mounting optionsCone-top pendantWall mountCeiling andpendant mount25 Angle stanchionHazVertor adapterringStraight stanchionPart No.DescriptionConduit hub sizeVA2Cone-top pendant¾"VA3Cone-top pendant1"VC2Ceiling mount¾"VC3Ceiling mount1"VB2-VIBWall mount¾"VB3-VIBWall mount1"VS4-VIB25 Angle stanchion11 4"VS5-VIB25 Angle stanchion11 2"VL4-VIBStraight stanchion11 4"VL5-VIBStraight stanchion11 2"HV1HazVertor adapter ringN/A Globes or refractorsRefractor globeHeat-resistant prismatic glass globePart No.Description*VGT15Heat-resistant prismatic glass globeVGL15R1IES Type I refractor globeVGL15R3IES Type III refractor globeVGL15R5IES Type V refractor globe* For silicone coating, please add the suffix "s" before the first digit (ex. STG)GuardsPolymeric guardPart No.DescriptionVGU22PPolymeric guardVGU22Cast guardCast guardOptional componentsExternal reflectors30 Angle reflectorPart No.DescriptionVR15PStandard dome, fiberglass-reinforced polyesterVRA15PAngular dome, fiberglass-reinforced polyesterStandard domeUS Catalog Hazlux Lighting 17

Area LightingHazlux 3 series 1Individual components (continued)LED engine modules and driversDriverLED engine moduleHazlux cat. no.LED engine cat. no. 120-277 VAC347-480 3.0146-HN/ADL020039502-H183.0144-HN/AInternal reflectorsCat. no.Description145.0056-HI3 Internal reflector 35 beam angle145.0057-HI4 Internal reflector 45 beam angle145.0058-HI6 Internal reflector 65 beam angleNote: only for models DL005, DL007 and DL010Photo sensor (Class I, div. 2, group A, B, C, D)Internal reflectorInternal reflector (actual application)18 Hazlux Lighting US BrochureCat. no.DescriptionHLPC-120-FG120VAC, 50/60HzHLPC-208-277-FG208/277VAC, 50/60Hz

1Dimensions — standard housing withglobe and guardPhotometry — standard housing withglobe and guardReference data14-¼ in. (362mm)18-1 1 32 in. (466mm)Ceiling mount13-3 8 in. (340mm)13-3 8 in. (340mm)Cone-top pendantCandlepower curveCatalog no.DL005EUN0TGC2EULuminaire lumens5,895Luminaire efficacy rating (LER)131Input watt45.07Spacing criterion (0-180)1.3Spacing criterion (90-270)1.3Spacing criterion (diagonal)1.44Ceiling mountCeiling mount16-3/4 in. (425mm)15-3 16 in. (386mm)Reference dataDL010EUN0TGC2EULuminaire lumens10,123Luminaire efficacy rating (LER)115Input watt88.19Spacing criterion (0-180)1.24Spacing criterion (90-270)1.24Spacing criterion (diagonal)1.416-1 8 in. (410mm)14-7 8 in. (378mm)Wall mountCandlepower curveCatalog no.25 Angle stanchion mountCeiling mount14-3/4 in. (375mm)15-3 16 in. (386mm)Reference data15-3/4 in. (400mm)Straight stanchion13-3 8 in. (340mm)HazVertor ringCandlepower curveCatalog no.DL015EUN0TGC2EULuminaire lumens15,605Luminaire efficacy rating (LER)128Input watt121.8Spacing criterion (0-180)1.08Spacing criterion (90-270)1.08Spacing criterion (diagonal)1.42Ceiling mountReference dataCandlepower curveCatalog no.DL020EUN0TGC2EULuminaire lumens20,476Luminaire efficacy rating (LER)123Input watt166.1Spacing criterion (0-180)1.46Spacing criterion (90-270)1.46Spacing criterion (diagonal)1.58US Catalog Hazlux Lighting 19

Area LightingHazlux 3 Series 1Photometry — standard housing withglass refractor — ceiling mountCeiling mountReference dataCandlepower curveCatalog no.DL010EUN0R1C2EULuminaire lumens8,047Luminaire efficacy rating (LER)92Total fixture watts87Maximum candela2,890Maximum candela ( 90 vertical)2,890Maximum candela at 90 vertical887 (11.0% luminaire lumens)Maximum candela from 80 to 90 Vertical1,463 (18.2% luminaire lumens)luminaireCeiling mountReference dataCandlepower curveCatalog no.DL010EUNOR3C2EULuminaire lumens8,649Luminaire efficacy rating (LER)99Total fixture watts87.27Maximum candela3,731Maximum candela ( 90 vertical)3,731Maximum candela at 90 vertical883 (10.2% fixture lumens)Maximum candela from 80 to 90 Vertical1,308 (15.1% fixture lumens)luminaireCeiling mountReference dataCandlepower curveCatalog no.DL020EUN0R5C2EULuminaire lumens17,004Luminaire efficacy rating (LER)102Total fixture watts166.3Maximum candela3,413Maximum candela ( 90 vertical)3,413Maximum candela at 90 vertical1,171.3 (6.9% fixture lumens)Maximum candela from 80 to 90 Vertical1,662.7 (9.8% fixture lumens)20 Hazlux Lighting US Brochureluminaire

Linear lighting2US Catalog Hazlux Lighting 21

222 Hazlux Lighting US Brochure

Linear lightingHazlux 6 series DFP series — vapor/dust proof lightingStandard features Front access fixture for hazardous locations Hinged front door frame with hinged ballast tray Spring loaded lamp holders – standard Available in 2, 3, 4, 5 and 6 lamp configurations Multiple hub locations can meet most wiring needsConstruction Sturdy 18 Ga. steel white powder coated housing 3 16" tempered glass lens Zinc latchesDFLPLEDS5K2UNPFTA1234567Ordering information1 Fixture series DFPLED Hazlux vapor/dust proof lighting2 Ballast factor LLow ballast factorSStandard ballast factorHHigh ballast factor3 Colortemperature4K4000K5K5000KElectrical Available with low, standard or high ballast factor Wattage ranging from 25W in the 2 lamp low ballast factor,to 111W in the 6 lamp high ballast factor configuration (seewattage table below) Through feed wiring Voltage of 120 to 277 and 347 available4 Lampquantity22 lamp configuration, 4' length33 lamp configuration, 4' length44 lamp configuration, 4' length55 lamp configuration, 4' length66 lamp configuration, 4' lengthUNUniversal voltage 120-277 50/60 Hz34347 voltOptions Adjustable surface mount brackets Cable mount Wire guard Acrylic lens 3 wire whip6 HubPFT1/2" NPT hubs on top and side7 OptionsKHAdjustable mounting brackets for surface mountCXCable mount (with 5' cable)PW3 Wire whipWGWire guardFFusingAAcrylic lensPPolycarbonate lensAccessories Chain or cable mount kit Adjustable surface or vertical mounting bracket5 VoltageCertifications and standardsClass I Division 2, groups A, B, C and DClass II Division 2, groups E, F and GClass III CSA 22.2 No. 137.0 CSA 22.2 No. 250.0 CSA C22.2 No. 250.13 UL listed (UL 1598) wet/damp UL 844 UL 8750 IP65, wet locationContact your Thomas & Betts sales representative to verify classification.US Catalog Hazlux Lighting 232

Linear lightingHazlux 6 series 2Dimensions - Nominal1/21/2NPThubsNPT HUBSBrackets for optionalmounting kits1/2both1/2 NPTNPT BOTHENDSendsHingedHINGEDreflectorREFLECTORBRACKETS FOROPTIONALMOUNTING KITSIntegratedaccessINTEGRATED ACCESSDOOR HINGEdoor hinge“A”"A"ROTARYDRAWLATCHES51511/2"1/2" 53531/8"1 8"55 55/16” 16""A":2 LAMP: 12 3/16"“A”: 3 & 4 LAMP: 16 3/16"5 & 6 LAMP:11/16"2 Lamp:12 3 2016" [30.96 cm]3 & 4 Lamp: 16 3 16" [41.12]5 & 6 Lamp: 20 11 16" [52.54 cm]Mounting accessory drawings (order separately)Chain KitP/N: DFP-CHAINPendant Style MountingNote: Conduit supply by others45” between conduitCable Hang KitP/N: DFP-CABLE (zinc coated), Qty 2 cables withtoggle ends and qty 2 self locking gripplesAdjustable Surface Mounting Bracket KitP/N: DFP-SURFACE (galvanized),toggle ends and qty 2 self locking gripples24 Hazlux Lighting US BrochureHINGED doorHingedDOORframeFRAME

2Photometry - LEDCeiling MountReference dataCandlepower CurveCatalog no.DFPLEDS4K434PFT1909Fixture lumens5,737 Lumens(4 Lamps)1432Fixture efficacy rating (LER)97477Input watt59.03Spacing criterion (0-180)1.26Spacing criterion (90-270)1.36Spacing criterion (diagonal)1.44PerformanceLamp qty. Source(ballastfactor)2 Lamp3 Lamp4 Lamp5 Lamp6 lumen outputColortemperatureModelRatedambientdeg. CClass I, div2 groups A,B, C & DClass II, div2 groups F&GClass IIIL: Low252800, 29004000K, 5000KS: Standard293200,33004000K, 5000KDFPLED40 CT5 (100 C)T4A (120 C)T4A (120 C)H: High373700,40004000K, 5000KL: Low37.54200,43504000K, 5000KS: Standard43.54800,49504000K, 5000KH: High55.55550,60004000K, 5000KL: Low505600,58004000K, 5000KS: Standard586400,66004000K, 5000KH: High747400,8004000K, 5000KL: Low62.57000,72504000K, 5000KS: Standard72.58000,82504000K, 5000KH: High92.59250,100004000K, 5000KL: Low758400,87004000K, 5000KS: Standard879600,99004000K, 5000KH: High11111100,120004000K, 5000KUS Catalog Hazlux Lighting 25

Linear lightingHazlux 7 series XFM series — explosion proof lighting2Standard features Factory sealed, lightweight cast natural aluminum 5 Different 1/2" NPT hubs entries at each end Center ballast placement for better balanced and low profile Available with 2, 3 and 4 lamp in a 4 ft length One piece painted aluminum reflector Suitable for use inside a spray boothXFMLEDS5K24UNP1234567Ordering information1 Fixture series XFMLED Explosion proof lighting2 Ballast factor LLow ballast factorSStandard ballast factorHHigh ballast factor3 Colortemperature4K4000K5K5000KElectrical Available with low, standard or high ballast factor Wattage ranging from 25W in the 2 lamp low ballast factor,to 74W in the 4 lamp high ballast factor configuration(see wattage table below) Voltage of 120 to 277 (50/60 Hz) and 347 available4 Lampquantity22 lamp configuration33 lamp configuration44 lamp configuration5 Length44' length6 VoltageUNUniversal voltage 120-277 50/60 Hz34347 voltOptions Wall and ceiling mount kit (4 lamps) Wire guard Polycarbonate shield 93% reflective premium specular reflector insert7 OptionsPPolycarbonate shieldWKStainless steel guard (not for sure in paint sprayapplications)MKWall/ceiling mount kit (4 lamps)Construction Cast natural aluminum 0.189" wall Borosilicate glass tubesAccessories Wall, ceiling and drop mount kitCertifications and standardsClass I Division 1, groups C and D Division 2, groups A, B, C and D Zone 1, Group IIB and IIAClass II Division 1 and 2, groups E, F and G Division 2, groups E, F and GClass IIIClass I and Class II Simultaneous Presence CSA C22.2 No.

Marine and coastal facilities Shipyards and shipbuilding plants . quick maintenance of Hazlux lighting fixtures The Hazlux LED fixtures engine and driver are . 3 lighting fixtures without removing the Crouse-Hinds top hat from the conduit system, eliminating the need to replace conduit and wiring. .

Related Documents:

Aug 21, 2019 · philips lytecaster 344dstx-302mrex-42017-4 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 led 120 . recessed white 4" recessed downlight led, 1160 delivered lumens, 3000k, 90 cri cree lighting eaton mcgraw-edison ist-af-350-

Dec 06, 2016 · COMMERCIAL LIGHTING 01-13 14-29 industrial lighting hazardous area lighting cleanroom lighting INDUSTRIAL LIGHTING street lighting area lighting induction lighting landscape lighting CITYSCAPE LIGHTING 30-51 ballast light sources HID lamps spares price list A

ABB Control SECRL - 1 2001-06-19 A New Contactor Range from ABB New Generation ABB Contactors. ABB Control SECRL - 2 2001-06-19 The ABB range of A The ABB range of A contactorscontactors A 9, A 12, A 16 A 26, A 30, A 40 A 50, A 63, A 75 A 95, A

Fifty‐five percent of growers grow crops under HPS lighting; 25% grow crops under LED lighting. Growers were familiar with many LED lighting manufacturers; and had evaluated or purchased LED lighting from GE Lighting, LumiGrow, Philips Lighting, PL Light Systems and Sunlight Supply.

LIGHTING ( DEFINED ) OPEN AREA (ANTI-PANIC) LIGHTING ( UNDEFINED ) HIGH RISK TASK LIGHTING Emergency lighting standards tree. Escape route lighting. 1.Escape Route Lighting The emergency lighting on a route forming part of the means of escape from a point in a building to final exit. 2.Open Area (Anti-panic) Lighting The part of emergency .

Small Lighting controls 20 80/22 21 Small Lighting-only 20 80/22 18 Large Lighting controls 10 80/31 10 Large Lighting-only 10 80/31 7 2013-2014 Small Lighting controls 40 80/16 42 Small Lighting-only 20 80/22 21 Large Lighting controls 30 80/18 33 Large Lighting-only 10 80/31 10 Total 160 80/15 162

Night Scene by Progress Lighting there are many different techniques for lighting areas or objects. these techniques are path lighting, spread lighting, spot lighting in an upward direction or downward direction, grazing, cross lighting, shadowing and silhouetting. see the night scene Catalog for more detailed information.

Vigilant LED High Bay - 60,000lm 14-15 Vigilant H2 Series LED High Bay 16-17 Vigilant LED High Bay 18-20 LED High Bay 480V AC Passive Power Supply 21-22 Vigilant 23-24 Vigilant 25-26 Wireless Occupancy Sensor 27 DuroSite LED Lighting for Industrial Applications DuroSite LED Lighting Fixtures for Industrial Applications Overview 7-8