Operating ManualULTIMA X-SeriesGas MonitorsOrder No. 10046690/09

MSA AUER GmbHThiemannstrasse 1D-12059 BerlinGermany MSA AUER GmbH. All rights reserved

MSAEC Declaration of ConformityEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductULTIMA XE MainULTIMA XE Main with HART Modulebased on the EC-Type Examination Certificate:DMT 02 ATEX E 202 Xcomplies with the ATEX directive 94/9/EC, Annex III. Quality Assurance Notificationcomplying with Annex IV of the ATEX Directive 94/9/EC has been issued byIneris of France, Notified Body number: 0080.The product is in conformance with the EMC directive 2004 / 108/ EC,EN 50270 :2006 Type 2 *, EN 61000 - 6 - 4 : 2007* EN 61000-4-6 : Ultima XE MAIN HART MODULE : occasional transmission error can appear at the2-wire version. A fault check has to be used at the receiver unit.The product complies with the directive 96/98 / EC (MarED),based on the EC-Type Examination Certificate :SEE BG 213.038The quality survaillance is under the control of SEE BG, Notified Body number: 0736We further declare that the product complies with the provisions ofLVD Directive 2006 / 95/ EC, with the following harmonised standard:EN 61010-1 :2002MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D InstrumentsGBULTIMA X Series3

EC Declaration of ConformityMSAEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductULTIMA SENSOR XEbased on the EC-Type Examination Certificate:DMT 02 ATEX E 202 Xcomplies with the ATEX directive 94/9/EC, Annex III. Quality Assurance Notificationcomplying with Annex IV of the ATEX Directive 94/9/EC has been issued byIneris of France, Notified Body number: 0080.The product is in conformance with the EMC directive 2004/108/EC,EN 50270:2006 Type 2, EN 61000-6-4:2007The product complies with the directive 96/98/EC (MarED),based on the EC-Type Examination Certificate:SEE BG 213.038The quality survaillance is under the control of SEE BG, Notified Body number: 0736MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D Instruments4ULTIMA X SeriesGB

MSAEC Declaration of ConformityEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductULTIMA XE SENSOR OX/TOXbased on the EC-Type Examination Certificate:DMT 02 ATEX E 202 Xcomplies with the ATEX directive 94/9/EC, Annex III. Quality Assurance Notificationcomplying with Annex IV of the ATEX Directive 94/9/EC has been issued byIneris of France, Notified Body number: 0080.The product is in conformance with the EMC directive 2004/108/EC,EN 50270:2006 Type 2, EN 61000-6-4:2007The product complies with the directive 96/98/EC (MarED),based on the EC-Type Examination Certificate :SEE BG 213.038The quality survaillance is under the control of SEE BG, Notified Body number: 0736MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D InstrumentsGBULTIMA X Series5

EC Declaration of ConformityMSAEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductULTIMA XIR SENSORin combination with ULTIMA XE MAIN orULTIMA X Junction Boxbased on the EC-Type Examination Certificate:DMT 02 ATEX E 202 Xcomplies with the ATEX directive 94/9/EC, Annex III. Quality Assurance Notificationcomplying with Annex IV of the ATEX Directive 94/9/EC has been issued byIneris of France, Notified Body number: 0080.The product is in conformance with the EMC directive 2004/108/EC,EN 50270:2006 Type 2, EN 61000-6-4:2007The product complies with the directive 96/98/EC (MarED),based on the EC-Type Examination Certificate:SEE BG 213.038The quality survaillance is under the control of SEE BG, Notified Body number: 0736MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D Instruments6ULTIMA X SeriesGB

MSAEC Declaration of ConformityEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductULTIMA XIbased on the EC-Type Examination Certificate:DMT 02 ATEX E 202 Xcomplies with the ATEX directive 94/9/EC, Annex III. Quality Assurance Notificationcomplying with Annex IV of the ATEX Directive 94/9/EC has been issued byIneris of France, Notified Body number: 0080.The product is in conformance with the EMC directive 2004/108/EC,EN 50270:2006 Type 2, EN 61000-6-3:2007The product complies with the directive 96/98/ EC (MarED),based on the EC-Type Examination Certificate:SEE BG 213.039The quality survaillance is under the control of SEE BG, Notified Body number: 0736MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D InstrumentsGBULTIMA X Series7

EC Declaration of ConformityMSAEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductULTIMA X Junction Box with Sensor typeULTIMA XE orULTIMA XIR orULTIMA XE OX/TOXbased on the EC-Type Examination Certificate:DMT 02 ATEX E 202 Xcomplies with the ATEX directive 94/9/EC, Annex III. Quality Assurance Notificationcomplying with Annex IV of the ATEX Directive 94/9/EC has been issued byIneris of France, Notified Body number: 0080.We further declare that the product complies with the EMC directive 2004/108/EC:EN 50270:2006 Type 2, EN 61000-6-4:2007MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D Instruments8ULTIMA X SeriesGB

MSAEC Declaration of ConformityEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductULTIMA XA (24V no relays)complies with the EMC directive 2004/108/ECEN 50270:2006 Type 2, EN 61000-6-4:2007MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D InstrumentsGBULTIMA X Series9

EC Declaration of ConformityMSAEC Declaration of ConformityManufactured by:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAThe manufacturer or the European Authorized Representative:MSA AUER GmbH, Thiemannstrasse 1, D-12059 Berlindeclares that theproductHART MODULEbased on the EC-Type Examination Certificate:DMT 02 ATEX E 202 Xcomplies with the ATEX directive 94/9/EC, Annex III. Quality Assurance Notificationcomplying with Annex IV of the ATEX Directive 94/9/EC has been issued byIneris of France, Notified Body number: 0080.We further declare that the product complies with the EMC directive 2004/108/EC:EN 50270:2006 Type 2, EN 61000-6-4:2007MSA AUER GmbHBerlin, October 2008Dr. Axel SchubertR&D Instruments10ULTIMA X SeriesGB

MSAContentsContents123456GBSafety Regulations . 151.1Correct Use . 151.2Liability Information . 151.3Safety and Precautionary Measures to be Adopted . 16Description . 192.1Marking, Certificates and Approvals according to theDirective 94/9/EC [ ATEX ] . 192.2Overview . 25Installation . 293.1Instructions for Installation . 293.2Installation with ULTIMA X Series Mounting Kit . 303.3Installing the ULTIMA XA Gas Monitor . 313.4Electrical Connection for the ULTIMA X Series Instruments . 313.5ULTIMA X Series Remote Sensor Module Installation . 35Operation . 374.1Hand-held Controller and Calibrator . 374.2HART Compatible Communications Interface . 384.3Commissioning . 38Calibration . 395.1Calibration Basics . 405.2Initial Calibration . 445.3Regular Calibration . 46Maintenance . 516.1ULTIMA XIR Cleaning Procedure . 516.2Replacing the ULTIMA XE/XA Sensor . 53ULTIMA X /Series11

Contents78912MSATechnical Data . 557.1Dimensions, Weight . 557.2Performance Specifications . 567.3Measuring Accuracy . 587.4ULTIMA XE – ATEX Performance Approval . 597.5ULTIMA XIR – ATEX Performance Approval . 61Ordering Information . 648.1Gas Monitors, Accessories . 648.2Replacement Parts . 66Appendix: Electrical Installation . 679.1Installation Outline Drawing [CE] - ULTIMA XE . 679.2Installation Outline Drawing [CE] - ULTIMA XE with XIR Sensor . 689.3Installation Outline Drawing [CE] - ULTIMA XA . 699.4Installation - Mounting Bracket . 709.5Remote non-reactive sensor and mounting bracket . 719.6HART module . 729.7ULTIMA XIR Remote Sensor . 739.8Installation Outline Drawing [CE] - ULTIMA XE Wiring Connections . 749.9HART Module Connections . 759.10Connection to MSA Controllers . 759.11Connection Drawings - SUPREMA . 769.12Connection Drawings - 9010/9020 . 779.13Connection Drawings - Gasgard . 789.14Cable Lengths and Cross-section - Gas Monitors . 799.15Cable lengths and Cross-section - Remote Sensor Module *) . 80ULTIMA X SeriesGB

MSA10111213ContentsAppendix: Instrument Specifications . 8010.1Instrument Operation . 8010.2Sensor Response to Interferants . 82Appendix: Instrument Messages . 8811.1Messages during Instrument Operation . 8811.2Messages during Instrument Configuration . 8811.3Instructions for Troubleshooting . 89Appendix: Optional Internal Relays and RESET Button . 9212.1General . 9212.2Mounting and Wiring of instruments . 9212.3Alarm Relays . 9412.4Fault Relay [Trouble] . 9512.5Optional RESET Button . 9512.6Calibration with RESET Button . 9612.7Relay Connections . 96Appendix: HART Specific Information . 9813.1HART Field Device Specification . 9813.2Universal Commands . 10313.3Common-Practice Commands . 10313.4Gas Type Descriptions . 12813.5Alarm Control Actions . 12813.6Calibration Modes . 12813.7Sensor Status Codes . 12913.8Gas Table Values . 13013.9Performance . 13113.10 Capability Checklist . 13313.11 Default Configuration . 134GBULTIMA X /Series13

ContentsMSA13.12 Calibration Using a HART Communicator . 13413.13 Standard Calibration Procedures . 13613.14 Initial Calibration Procedures . 14013.15 User [Stepped] Calibration Procedures . 14013.16 Sample Calibration Display Screens . 14313.17 Troubleshooting . 15614ULTIMA X SeriesGB

MSASafety Regulations1Safety Regulations1.1Correct UseThe ULTIMA X Series Gas Monitors are fixed Gas Monitors for measuring toxicand combustible gases as well as oxygen. They are suitable for outdoor and indoorapplications without limitations, e.g. offshore industry, chemical and petrochemicalindustry, water and sewage industry. Using sensors, the instruments test the ambient air and trigger the alarm as soon as the gas exceeds a specific concentrationlevel.It is imperative that this operating manual be read and observed when using theproduct. In particular, the safety instructions, as well as the information for the useand operation of the product, must be carefully read and observed. Furthermore,the national regulations applicable in the user's country must be taken into accountfor a safe use.Danger!This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the function of the device and thereby seriously compromise the user's life.Before use the product operability must be verified. The product mustnot be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spareparts have not been used.Alternative use, or use outside this specification will be considered as non-compliance. This also applies especially to unauthorised alterations to the product and tocommissioning work that has not been carried out by MSA or authorised persons.1.2Liability InformationMSA accepts no liability in cases where the product has been used inappropriatelyor not as intended. The selection and use of the product are the exclusive responsibility of the individual operator.Product liability claims, warranties also as guarantees made by MSA with respectto the product are voided, if it is not used, serviced or maintained in accordance withthe instructions in this manual.GBULTIMA X Series15

Safety Regulations1.3MSASafety and Precautionary Measures to be AdoptedAttention!The following safety instructions must be observed implicitly. Only in thisway can the safety and health of the individual operators, and the correctfunctioning of the instrument, be guaranteed.16-The ULTIMA X Series Gas Monitors described in this manual must be installed, operated and maintained in strict accordance with their labels, cautions,instructions, and within the limitations stated.-The ULTIMA X Series Gas Monitor is designed to detect gases or vapours inair. The concentration of gases or vapours in steam or inerted and oxygen-deficient atmospheres cannot be measured with this instrument. For oxygen deficiency measurements, use the oxygen sensor.-For oxygen deficiency or enrichment measurements use the 0-25 % oxygensensor for oxygen measurement during inerting use the 0-10 % oxygen sensor.-The ULTIMA XIR Infrared Combustible Gas Monitor detects the presence ofmost combustible gases by measuring the infrared light absorbed during thepresence of these gases. This monitor however, does NOT detect the presenceof hydrogen gas and must never be used to monitor for hydrogen gas.-The ULTIMA XIR Combustible Gas Monitor does not detect the presence ofacetylene gas and the presence of acetylene gas will degrade the sensor performance.-Protect the ULTIMA X Series Gas Monitor from extreme vibration. Do notmount the sensing head in direct sunlight as this may cause overheating of thesensor.-Electrochemical sensors are sealed units which contain a corrosive electrolyte.Should a sensor develop leakage, it must be immediately removed from serviceand disposed of properly. Caution must be exercised so that the electrolytedoes not contact skin, clothing or circuitry otherwise personal injury [burns] and/or equipment damage may result.-The only absolute method to ensure proper overall Operation of anULTIMA X Series Monitor is to check it with a known concentration of the gasfor which it has been calibrated. Consequently, calibration checks must be included as part of the routine inspection of the System. When calibration gas isapplied via the gas inlet of a SensorGard, a calibration cap shall be used for prevention against influence of the surrounding atmosphere.ULTIMA X SeriesGB

MSAGBSafety Regulations-As with all Gas Monitors of these types, high levels of, or long exposure to, certain compounds in the tested atmosphere could contaminate the sensor. In atmospheres where the ULTIMA X Series Gas Monitor may be exposed to suchmaterials, calibration must be performed frequently to ensure that the operationis dependable and display indications are accurate.-The ULTIMA X Series Gas Monitor must not be painted. If painting is done inan area where a monitor is located, care must be exercised to ensure that paintis not deposited on the sintered metal flashback arrestor in the gas sensor inlet,if so equipped. Such paint deposits would interfere with the gas diffusionprocess.-Use only genuine MSA replacement parts when performing any maintenanceprocedures provided in this manual. Failure to do so may seriously impair instrument performance. Repair or alteration of the ULTIMA X Gas Monitor, beyondthe scope of these maintenance instructions or by anyone other than an authorised MSA service personnel, could cause the product to fail to perform as designed.-The ULTIMA X Series is designed for applications in hazardous areas underatmospheric conditions.-For correct measurements, the ULTIMA XE and XA combustible gas sensorsrequire an oxygen concentration greater than 10 Vol%. Oxygen enriched atmospheres, greater then 21 Vol%, can affect the measurement and the electrical safety of the Gas Monitor.-ULTIMA XE and XA combustible: When the ULTIMA XE and XA monitor thesurrounding atmosphere, the measuring gas reaches the sensors by diffusion.In this case the measuring values are smaller than the measuring values if thesame gas concentration is applied via SensorGard during calibration. If the airspeed during monitoring the surrounding atmosphere is higher than 1m/s thedeviations of the measuring values are within the limits stated byEN 60079-29-1:2007.-ULTIMA XE and XA combustible: The difference of air pressure between operation and calibration shall not be greater than 10 kPa.-The response time of the ULTIMA XIR will be increased by significant dust deposits on the XIR SensorGard. Checks for dust deposits must be done at regular intervals.-If a relay version of the ULTIMA X Series Gas Monitor is used, the highestalarm used shall be set for latching.ULTIMA X Series17

Safety Regulations-Catalytic combustible gas sensors may produce low or zero response to combustible gas after exposure to substances as Silicon, Silane, Silicate, Halideand compounds containing Fluorine, Chlorine, Iodine or Bromine.-ATEX applications 18MSAHART shall only be used for ULTIMA configuration, calibration or diagnostics. For safety relevant applications, the 4-20 mA analogue output shall beused for measuring values.The Alert option shall be set to "ON"ULTIMA X SeriesGB

MSADescription2Description2.1Marking, Certificates and Approvals according to theDirective 94/9/EC [ ATEX ]HART ModuleManufacturer:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAProduct:HART ModuleType of protection:EN 60079-0:2006, EN 60079-1:2004, EN 60079-11:2007Performance:only in combination with ULTIMA XE MAINMarking:HART MODULEII 2G Ex d [ib] IIC T5-40 C Ta 60 CUo 6,14 V , Io 170 mA , Co 34 uF , Lo 1,3 mHPo 260 mW , Um 250 VACEC-Type Examination Certificate:DMT 02 ATEX E 202 XQuality Assurance Notification:0080Year of Manufacture:see Serial NumberSerial Nr.:see LabelEMC Conformance according to the Directive 2004/108/ECEN 50270:2006 Type 2, EN 61000-6-4:2007GBULTIMA X Series19

DescriptionMSAULTIMA XE MainManufacturer:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAProduct:ULTIMA XE Main with:ULTIMA XE SENSOR ,ULTIMA XIR SENSORULTIMA XE SENSOR OX/TOXULTIMA XE SENSOR OX/TOX iaULTIMA XE Main with HART Module and with:ULTIMA XE SENSOR ,ULTIMA XIR SENSORULTIMA XE SENSOR OX/TOXType of protection: EN 60079-29-1:2007, EN 60079-11:200720Performance:EN 60079-29-1:2007, EN 50104:2002 , EN 50271:2001Int.Relais LEDs , UB 19 V-30 V, Ia 4-20 mA, 3-WireGasOxygen: 0 -10 Vol %0 - 25 Vol % PFG-Nr: 41301103Gas:Measure range : 0-100% LELULTIMA XE:Methane, Propane,2-Butanone, Acetone, Acetylene, 1,3-Butadiene, Diethyl ether, Ethane, Ethanol, Ethylene, Ethyl acetat,Ethylene oxide, (FAM-) Standard mineral spirit 65/95,n-Butane, n-Hexane, n-Pentane, 2-Propanol, Propene,Propylene oxide, Hydrogen, Cyclo pentane, Allyl alcohol,i-Butene, i-Butane, Methanol, Cyclohexane.ULTIMA X IR:Methane, Propane,2-Butanone, Acetone, 1,3-Butadiene,Diethyl ether, Ethane, Ethanol, Ethyl acetat, Ethylene oxide,(FAM-) Standard mineral spirit 65/95, i-Butyl acetate,n-Butyl acetate, n-Butane, n-Hexane, n-Nonane, n-Pentane,2-Propanol, Propene, Propylene oxide, Toluene, Xylene,Cyclo pentane, Allyl alcohol, i-Butene, i-Butane, Methanol.ULTIMA X SeriesGB

MSADescriptionMarking:ULTIMA XE MAINII 2G Ex d IIC T5-40 C Ta 60 Cif equipped with HART MODULE and XP portII 2G Ex d [ib] IIC T5Uo 6,14 V , Io 170 mA , Co 34 uF , Lo 1,3 mHPo 260 mW , Um 250 VACassembled with the following components:ULTIMA XEULTIMA X IRII 2G Ex d IIC T4III 2G Ex d IIC T5-40 C Ta 60 C-40 C Ta 60 Conly mounted with XE MAINULTIMA XE Ox/Tox iaII 2G Ex ia IIC T4 only together with the ia barrier-40 C Ta 60 CSpecial conditions for safe use:Some of the flameproof joints have widths that are bigger and gaps that are smallerthan the values required in table 2 of IEC 60079-1. In case of repair or exchange ofparts forming these flameproof parts the widths and the gaps of these joints haveto comply with the values of commercial specification no. 10000012327 signed04.05.2005 and drawing no. 10000017784 signed 04.05.2005.EC-Type Examination Certificate: DMT 02 ATEX E 202 XQuality Assurance Notification:Year of Manufacture:Serial Nr.:0080see Serial Numbersee LabelEMC Conformance according to the Directive 2004 / 108 / ECEN 50270:2006 Type 2, EN 61000-6-4:2007EN 61000-4-6 : Ultima XE MAIN HART MODULE : occasional transmission errorcan appear at the 2-wire version. A fault check has to be used at the receiver unit.MarED Conformance according to the Directive 96/98 ECSEE BG 213.038, Notified Body number: 0736LVD Conformance according to the Directive 2006/95/ECDIN EN 61010-1:2002-08GBULTIMA X Series21

DescriptionMSAULTIMA XIManufacturer:Mine Safety Appliances Company1000 Cranberry Woods DriveCranberry Township, PA 16066 USAProduct:MSA ULTIMA XIType of protection: EN 60079-0:2006, EN 60079-1:2004Performance:EN 60079-29-1:2007, EN 50271:2001Gas:Measure range : 0-100% LELULTIMA XE:Methane, Propane,2-Butanone, Acetone, 1,3-Butadiene,Diethyl ether, Ethane, Ethanol, Ethyl acetat, Ethylene oxide,(FAM-) Standard mineral spirit 65/95, i-Butyl acetate,n-Butyl acetate, n-Butane, n-Hexane,n-Nonane, n-Pentane,2-Propanol, Propene, Propylene oxide, Toluene, Xylene,Cyclo pentane, Allyl alcohol, i-Butene, i-Butane, MethanolMarking:ULTIMA XIII 2G Ex d IIC T5-40 C Ta 60 CUm 30 V DC , P nom 4,2 WEC-Type Examination Certificate:DMT 02 ATEX E 202 XSpecial conditions for safe use connected only to a connection box without any other electronic components inside of the enclosure:ULTIMA XI equipped with a tapered NPT thread for use with an flameproof enclosure „d“ , which is certified for these use:In case of mounting the gas monitor to an enclosure of protection type flameproofenclosure „d“ the reference pressure of the separate enclosure for the connectionmust not exceed 20 bar. The test of the mechanical strength of the separate enclosure for the connection and the test of the connecting thread with respect to explosion hazards must be ensured within the framework of the type test of the electricalapparatus, that is attached to the gas monitor ULTIMA XI. The threaded hole towhich the gas monitor is attached to must meet the requirements of section 5.3(Table 3/4) DIN EN 60079-1.22ULTIMA X SeriesGB

MSADescriptionULTIMA XI equipped with a metric thread for use with an increased safety enclosure „e“, which is certified for these use:In case of mounting the gas monitor to enclosures in type of protection increasedsafety "e" the mechanical resistance and the IP protection of the mounted enclosure has to be ensured by the type test of the electrical apparatus being mountedto the gas monitor. After mounting of the gas monitor onto an enclosure in type ofprotection increased safety "e" the clearances and creepage distances must meetthe requirements of 4.3 (Table 1) of EN 60079-3. The non-sheathed cables of thegas monitor must be routed and connected so as to be mechanically protected andcorresponding to the temperature resistance of the cables as per 4.2, 4.5.1 and 4.8of EN 60079-3.The gas monitor ULTIMA XI must be screwed into the housing wall such that it issecured against self-loosening. The specified minimum thread depth of the add-onhousing has to be observed.The gas monitor ULTIMA XI must be included into the earthing and equipotentialbonding of the complete unit including the enclosure for connecting.Quality Assurance Notification:0080Year of Manufacture:see Serial NumberSerial Nr.:see LabelEMC Conformance according to the Directive 2004/108/ECEN 50270:2006 Type 2, EN 61000-6-3:2007MarED Conformance according to the Directive 96/98 ECSEE BG 213.039, Notified Body number: 0736GBULTIMA X Series23

DescriptionMSAULTIMA X Junction BoxManufacturer:Mine Safety Appliances Company1000 Cranberr

MSA Safety Regulations ULTIMA X GB Series 15 1 Safety Regulations 1.1 Correct Use The ULTIMA X Series Gas Monitors are fixed Gas Monitors for measuring toxic and combustible gases as well as oxygen. They are suitable for outdoor and indoor applications without lim ita

Related Documents:

ULTIMA X3 Technology [Digital Data Transfer and up to 3 Sensors per Monitor] The ULTIMA X3 has all the benefits of the ULTIMA X series and is also capable of digital communication. A maximum of 31 ULTIMA X3 transmitters can be connected to the same line via ModBUS RTU. Since ULTIMA X3

ULTIMA X3 Technology [Digital Data Transfer and up to 3 Sensors per Monitor] The ULTIMA X3 has all the benefits of the ULTIMA X series and is also capable of digital communication. A maximum of 31 ULTIMA X3 transmitters can be connected to the same line via ModBUS RTU. Since ULTIMA X3

ULTIMA Repair Kit P80KV8 (Viton Seals) T o pr o te c t y our W a r a n t y l U s e o nlyEn e r p a c O i See on last page. T o pr o te c t y our W a r a n t y l U s e o nlyEn e r p a c O i See on last page. 4 Item included in: ULTIMA Repair Kit P80K8 (Standard Seals) ULTIMA Repair Kit P80KV8 (Viton Seals) ULTIMA Release Valve Kit P39RVK

Ultima X3 Technology (X to the Power of 3) Ultima X3 Technology for Ultima X Series Gas Monitors features: Multi-sensing Up to 31 monitors with up to 3 sensors inputted per monitor for 93-sensor total Combination of electrochem

ULTIMA #53-644 Programmable Digital Ignition System DESCRIPTION The Ultima Digital Ignition is designed to provide the correct curves and total timing for Ultima enginesand other larger cubic inch or high performance engines. These units will also replace the OEM HD factory ignition module and sensor used on 1983 and later Harley-Davidson EVO motors.

SMB_Dual Port, SMB_Cable assembly, Waterproof Cap RF Connector 1.6/5.6 Series,1.0/2.3 Series, 7/16 Series SMA Series, SMB Series, SMC Series, BT43 Series FME Series, MCX Series, MMCX Series, N Series TNC Series, UHF Series, MINI UHF Series SSMB Series, F Series, SMP Series, Reverse Polarity

Read this manual carefully before using your Ultima NEO unit. The manufacturer strongly recommends carefully reading . -20 -- 80 , 8%--80% R.H. 9. Temperature & R.H. of transportation: -20 -- 80 , . TENS/EMS/MIC/IF Model Ultima NEO combines the systems of a TENS (Transcutaneous Electrical Nerve Stimulator) device, an EMS or NMES .

Agile software development refers to a group of software development methodologies based on iterative development, where requirements and solutions evolve through collaboration between self-organizing cross-functional teams. The term was coined in 2001 when the Agile Manifesto was formulated. Different types of agile management methodologies can be employed such as Extreme Programming, Feature .