MasterSeal AWB 660 - Master Builders Solutions

2y ago
17 Views
3 Downloads
203.65 KB
5 Pages
Last View : 13d ago
Last Download : 3m ago
Upload by : Annika Witter
Transcription

Technical Data Guide707 27 26Fluid-Applied MembraneAir BarriersMasterSeal AWB 660 Vapor permeable air/water-resistive barrierFORMERLY ENERSHIELD HPDESCRIPTIONPACKAGINGMASTERSEAL AWB 660 5-gallon pail (18.9 L) pailACCESSORIESMasterSeal AWB 971 FIB: 4": 4" x 180 ft (101.5 mm x 54.8 m) roll 6": 6" x 180 ft (152.4 mm x 54.8 m) roll 9": 9" x 180 ft (228.5 mm x 54.8 m) roll 56 MasterSeal AWB 975 FIB pieces perdispenser boxMasterSeal AWB 970 FIB 4: 4" x 100'(10.2 cm x 30.5 m) rolls - 9 rolls per cartonMasterSeal AWB 970 FIB 9: 9"x 100'(22.9 cm x 30.5 m) rolls - 4 per cartonMasterSeal AWB 950 P 19 liter (5 gallon)pails, 3.8 liter (1 gallon) bottles with4 bottles per cartonMasterSeal AWB 960 AC 0.95L (1 quart)plastic bottles with 8 bottles per cartonMasterSeal AWB 900 20 oz. propak with20 propaks per cartonSHELF LIFEMasterSeal AWB 660 has 2 years shelf lifewhen properly storedSTORAGEStore in unopened containers in clean, dryplace protected liquid system componentsfrom freezing. Store at no less than 4 C(40 F) and below 49 C (120 F). Protectfrom extreme heat and direct sunlight. Donot stack pallets.VOC CONTENT17 g/l, or 0.14 lbs/gal less water andexempt solvents per ASTM D2369 (basedin part on EPA method 24).SOLIDS74%COLORGrayMasterSeal AWB 660 is a one-component, fluid-applied vapor permeable air/water-resistivebarrier. This waterproof, resilient coating may be spray-, roller-, or brush-, or trowel- applied directlyto approved above grade wall substrates. It provides excellent secondary moisture protection behindmost wall claddings including brick, siding and metal panels.APPLICATION/APPROVED SUBSTRATEFor use over the following exterior wallsubstrates:Poured concrete/unit masonry, pouredconcrete/unit masonry treated withMasterSeal AWB 600 FL , ASTM C1177type sheathings, including DensGlass or DensElementexterior sheathing, eXP sheathing, GlasRoc sheathing, Securock glass-mat sheathing, Weather Defense Platinum sheathing, GreenGlass sheathing,PermaBase cement-board by NationalGypsum and other cement-boards (ASTMC1325 Type A Exterior), untreated ExposureI or exterior plywood sheathing (grade C-D orbetter), untreated Exposure I OSB, gypsumsheathing (ASTM C79/ASTM C1396), Fireresistive sheathing such as MagTec, LPFlameBlockDo not use MasterSeal AWB 660 forbelow-grade applications or on surfacessubject to water immersionCoverageSubstrate ASTM C1177 Type Sheathing450 ft2 (41 m2) per pailCement Board500 ft2 (46 m2) per pail Plywood*265 ft2 (24 m2) per pail Oriented Strand Board (OSB)265 ft2 (24 m2) per pail Concrete Masonry Units (CMU)*Standard Weight 265 ft2 (24 m2) per pailMedium Weight 180 ft2 (17 m2) per pailLight Weight 125 ft2 (12 m2) per pail Poured Concrete*46 m2 (500 ft2) per pail Concrete / Masonry with MasterSeal AWB 600 FL46 m2 (500 ft2) per pail Embed Sheathing Fabric4" Sheathing Fabric: 630 ft (192 m) per pail6" Sheathing Fabric: 420 ft (128 m) per pail9" Sheathing Fabric: 280 ft (85 m) per pail *Roll or spray / backroll for optimum coveragerate. Other application methods may provideless coverage. Actual results may varydepending on surface porosity, roughness,moisture uptake or other factors. ote:NMasterSeal AWB 971 FIB saturated withMasterSeal AWB 660, when applied permanufacturer instructions, self gauges to a30-40 mil thickness.A brand ofwww.master-builders-solutions.com/en-us

Technical Data GuideMasterSeal AWB 660MasterSeal AWB 660 complies with the air barrier requirements of the Massachusetts State Energy CodeFeaturesBenefitsICC ESR-3209 Evaluation ReportConfirms compliance with IBC, IRC, and IECL requirementsABAA evaluatedApproved for projects requiring ABAA specifications and quality assurance 1% of allowable air leakage per ASTM E2357 Air Leakage of Buildingassemblies testEasily meets air tightness requirements defined by ASHRAE 189.1, ASHRAE 90.1and ABAAMeets ASTM D1970 nail sealability requirements with and without sheathing fabricSelf sealing performanceOne component, low-VOC formulationEasy to apply, meets VOC requirements in all 50 statesNonflammable as appliedWorkplace safetyMineral oil and plasticizer freeWill not dry out or crack due to loss of oil / plasticizer over timeWater basedCleans up with water; solvents and citrus based cleaners not requiredTough, abrasion resistantRugged membrane resists damage after installationApproved for use with MASTER BUILDERS SOLUTIONS EIFS and stucco systemsFull system warranty, seamless membrane for buildings with multiple claddingsLow temperature performance with MasterSeal AWB 960 ACExtends minimum application temperature to -4 C (25 F)180 day outdoor exposure ratingFlexible construction schedulingTEST DATAPROPERTYRESULTSTEST METHODAir Leakage of Air Barrier Assemblies0.0007 l/s.m2 (0.0001 cfm/ft2) @ 75 Pa (1.57 psf) positive/post conditioning0.0014 l/s.m2 (0.0003 cfm/ft2) @ 75 Pa (1.57 psf) negative/post conditioningASTM E 2357Air Permeance of Building Materials0.0049 l/s.m2 @ 75 Pa (0.00098 cfm/ft2 @ 1.57 psf)(.00098 cfm/ft(2) @ 1.57 psfASTM E 2178Rate of Air Leakage0.0185 l/s·m2 @ 75 Pa (0.0037 cfm/ft2 @ 1.57 psf)ASTM E 283Water Vapor Transmission18 Perms (grains/Hr. in Hg. ft2) @ 10 mils wet film thickness14 Perms (grains/Hr. in Hg. ft 2) @ 20 mils wet film thicknessASTM E 96 Method BPull-Off Strength of CoatingsPass - Min. 110 kPa (15.9 psi) or substrate failure (Tested over exterior gypsumsheathing, ASTM C1177 glass-mat sheathing, cement board, OSB, plywood; pvcand galvanized flashing)ASTM D 4541Nail Sealability(without Sheathing Fabric)Pass - No water penetration at galvanized roofing nail penetration under 127 mm (5")head of water after 3 days at 4 C (40 F)ASTM D 1970Compound Stability(Elevated Temperature)No flowing, dripping or drop formation up to 177 C (350 F)ASTM D 5147 Section 15Surface BurningClass A Flame Spread ( 25)Class A Smoke Developed Spread ( 450)ASTM E 84Radiant Heat Multi-Story TestsPassed using numerous wall assemblies. Engineering analyses available upon request.NFPA 285Fire ResistanceWill not add or detract from the rating of a fire resistive wall assemblyASTM E 119/UL 263Drainage Efficiency99%ASTM E 2273

Master Builders C-ES AC 212: Acceptance Criteria for Water-Resistive Coatings used as Water-Resistive Barriers over Exterior SheathingPROPERTYRESULTSTEST METHODNo cracking at joints or interface of flashingNo cracking at joints or interface of flashingNo cracking at joints or interface of flashingNo water penetration after 90 min @ 299 Pa (6.24 psf) Tested over OSBand gypsum sheathingASTM E 1233 Procedure AASTM E 72ICC-ES AC 212ASTM E 331No cracking or bond failure to substrateNo cracking or bond failure to substrateNo water penetration at 55 cm (21.7") water column for 5 hoursICC-ES AC 212ICC-ES AC 212AATCC 127-1985Freeze-ThawNo sign of deleterious effects after 10 cycles (Tested over exterior gypsum sheathing,ASTM C1177 glass-mat sheathing, cement board, OSB, plywood)ASTM E 2485 (Method B)Water ResistanceNo sign of deleterious effects after 14 day exposure (Tested over exterior gypsumsheathing, ASTM C1177 glass-mat sheathing, cement board, OSB, plywood)ASTM D 2247Tensile Bond 103 kPa (15 psi) Tested over exterior gypsum sheathing, ASTM C1177 glassmatsheathing, cement board, OSB, plywood, CMU; pvc and galvanized flashingASTM C 297Tensile Bond(before & after freeze-thaw) 103 kPa (15 psi) avg; no failure of the lamina after 10 cycles freeze-thaw(Tested over various substrates)ASTM C 297Sequential Testing1. Structural2. Racking3. Restrained Environmental Conditioning4. Water PenetrationSequential Testing - Weathering1. UV Light Exposure2. Accelerated Aging3. Hydrostatic PressureICC-ES AC 148: Acceptance Criteria for Flexible Flashing MaterialsPROPERTYRESULTSTEST METHODNo No crackin

sheathing, ASTM C1177 glass-mat sheathing, cement board, OSB, plywood) ASTM D 2247 Tensile Bond 103 kPa (15 psi) Tested over exterior gypsum sheathing, ASTM C1177 glassmat sheathing, cement board, OSB, plywood, CMU; pvc and galvanized flashing

Related Documents:

MasterSeal HLM 5000 is a one-component, moisture-curing, bitumen-modified polyurethane elastomeric waterproofing membrane for exterior below-grade or between-slab applications. It is available in four grades: MasterSeal HLM 5000 SL (self-leveling/squeegee) MasterSeal HLM 5000 S (spray) MasterSeal HLM 5000 T (trowel) MasterSeal HLM 5000 R (roller)

MasterSeal HLM 5000 STORAGE AND SHELF LIFE Store in unopened containers in clean, dry conditions at 4 to 27 C. During storage, an easily removed skin of MasterSeal HLM 5000 may form, which does not affect performance of the product. MasterSeal HLM 5000 has a shelf life of 12 months for pails. VOC CONTENT - MasterSeal HLM 5000 SL: 183 g/L

1,8kg/m2 de MasterSeal 6100 FX en polvo). poseedor final del producto. Rendimiento saco 15kg: 8,3m2 Consumo Rendimiento 10kg Reducción consumo MasterSeal 550 4,5kg/m2 2,20m2 - MasterSeal 560 2,5kg/m2 5,00m2 45% MasterSeal 6100 FX 1,8kg/m2 5,55m2 60% Estos consumos son teóricos y dependen de la rugosidad

Refer to product data sheet on MasterSeal P 173 or MasterSeal P 176, and consult Technical Service for additional information. 2.For immersion applications, MasterSeal P 173 must be used. 3.For green concrete applications, Mast

MasterSeal HLM 5000 SL, HLM 5000 S y HLM 5000 R: cubetas de 18.95 L (5 gal) y tambores de 208 L (55 gal) disponible por pedido MasterSeal HLM 5000 T: cubetas de 18.95 L (5 gal) MasterSeal 995 (Sonoshield Reinforcing Fabric): rollos de 91 por 0.9 m (300 ft

products e.g. MasterSeal 590, MasterSeal P 385 Part D or MasterEmaco S 5440 RS Iron / steel: Should be sand blasted to a SA 2½ finish prior to application of the product. No primer coat is needed for application of MasterSeal M 790 on steel. Substrate temperature

MasterSeal systems can not be applied in situations of water coming in counter pressure. In this case it is necessary to provide drainage and then block the coming water with the fast setting MasterSeal 590 mortar. In the event that you encounter any patches still wet, apply one or two coats of MasterSeal P 385 after 48-72 hours

MasterSeal Traffic 1500 ideal for various vehicular or pedestrian traffic solutions repairable and recoatable to extend the useful life of the system MasterSeal Traffic 1500 DeSCRIPtIOn MasterSealTraffic 1500 waterproofing systems are composed of: – MasterSeal M 200, a one-component, moisture-curing polyurethane,File Size: 1MBLocation: DeSCRIPtIOnPage Count: 8