For Global Applications - Eaton

2y ago
14 Views
3 Downloads
901.63 KB
10 Pages
Last View : 28d ago
Last Download : 3m ago
Upload by : Mara Blakely
Transcription

Ex-Cell stainless steel andpainted steel enclosuresHigh performance, high reliability enclosuresfor global applicationsCl. I, Div. 2, Groups A, B, C, DACl. I, Zone 1Type 3S, 4, 4XIP66IECEx/ATEXTR-CU/EAC2EApplications: Manufactured to meet the most demanding industrial andhazardous area environmental applications A globally certified enclosure and termination solution for Type 3S,4 (painted mild steelB and stainless steel), and 4X (stainless steel)applications Certified to the impact, thermal and IP66 ingress requirements ofEx standardsFeatures:2E Available in a comprehensive range of sizes, each with variousconfigurations for a multitude of applications Offers unique design features, precision manufacturing andthe highest quality materials, making it the premier choice forinstrumentation and electrical applications across the globe Over 100 standard sizes in both stainless steel and painted steelB Single door enclosures up to 63” x 48” x 16” (1600 x 1200 x400mm) Flush mount enclosures Eagle enclosures with a sloped water shedding designCertifications and compliances: Class I, Division 2, Groups A, B, C, DA; Class I, Zone 1cULus to UL50/C22.2 No. 94-M91UL Listed E115376 (Ordinary Location)Type 3S, 4 – painted mild steelB; Type 4X/IP66 – stainless steelATEX and IECEx component certificates (BAS 15ATEX0099U andIECEX BAS15.0071U) 2G Ex eb IIC Gb or 2D Ex tb IIIC Db TR-CU and EAC certifiedStandard materials and finishes: 1.2mm thick enclosure – 316L (1.4404 to EN10088) stainless steel(standard); 304 (1.4301 to EN10088) stainless steel (optional) Enclosure finish – superior corrosion-resistant chromium enrichedelectro-polished surface Gasket – foam-in-place silicone on lid (standard); cut silicone(optional) Keyed lock fastening mechanism – stainless steel Door hinges – stainless steel Enclosure mounting – four external 3mm stainless steel weldedlugs, 11mm Ø holes/slots Equipment mounting – four (up to 10 depending on size) stand-offpillars 9mm Ø, 15mm high, tapped M6 x 10, for rail/mounting plate Enclosure earth – M10 external and internal stainless steel earthstud assembly Mounting plate – 2mm sheet steel with zintec finish (available instainless steel) Gland plates – rounded corners to eliminate sharp points; 3mmthickness (standard); 6mm thickness (optional)Technical specifications: Empty enclosure:- Standard service temperature: -55 C to 120 C- Extended service temperature: -60 C to 135 C (with suffix 'E') Impact resistance: 7 J (Nm)Ex-Cell-T / XL-T terminal boxes:Ex-Cell enclosures are available assembled as custom configuredand certified terminal boxes. Options include custom entries, cableglands and plugs with built-in terminals (Ex-e and Ex-i) and otherequipment. Contact factory for ordering details.Standards: IEC/EN/UL/CAN 60079-0 IEC/EN/UL/CAN 60079-7 IEC/EN 60079-31 IEC/EN 60529Certificates: BVS16 ATEX-E-115X IECEx BVS 16.0080X UL Listed E108296 (Hazardous Location) RU C-DE.AA87.B.00885Ambient temperaturesC: -55 C to 40 C (with temperature class T6 and maximum surfacetemperature of T80 C) -55 C to 55 C (with temperature class T5 and maximum surfacetemperature of T95 C) -55 C to 55/80/100/110 C (with temperature class T4 and surfacetemperature of T135 C) -60 C to 80/100/110 C (with temperature class T4 and surfacetemperature of T135 C) – requires suffix 'E' extended temperatureversion)Materials: 316L electro-polished stainless steel (standard); 304 stainless steel(optional)Electrical ratings: Rated voltage up to 690V AC/DC; rated current up to 400A;terminal cross-sections up to 240mm2Markings: ATEX and IECEx: Ex eb IIC T6/5/4 Gb; Ex tb IIIC T80/95/130 C Dbor Ex tb IIIC T80/95/130 C NEC 500 and NEC 505: Class I, Division 2, Groups A, B, C, D andClass I, Zone 1, AEx e IIC T6/5/4 EAC CU TR: 1Ex e IIC T6/T5 Gb X or Ex tb IIIC T80/95/130 C Db XAWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.BPainted mild steel not available with ATEX or IECEx.CTemperature range depends on ratings of built-in components.*Painted versions only available on demand.762www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton

Ex-Cell stainless steel andpainted steel enclosuresHigh performance, high reliability enclosuresfor global applicationsMounting options Enclosure is mounted using four heavyduty, 3mm thick, surface weldedstainless steel lugs One set of lugs are slotted for ease ofmounting, providing a secure, reliablemeans of mounting the enclosureAvailable in vertical or horizontalconfigurationCl. I, Div. 2, Groups A, B, C, DDCl. I, Zone 1Type 3S, 4, 4XIP66Glanding options Available with up to 4 gland plates(3mm thick) on each side Five possible combinations of 0, 1, 2, 3or 4 gland plates available Gland plates secured via rivetednutserts for improved sealingIECEx/ATEXTR-CU/EAC2EOne-piece gasket High integrity one-piece siliconesealing gasket provides an IP66 ratingand excellent recovery and re-sealingproperties for continuous environmentalprotection2EQuarter turn lock Standard cover featuresa 1/4 turn keyed lockfastening mechanism thatprovies a rapid meansof achieving an IP66rated seal for reliableenvironmental protection Earth/ground stud assembly External and internal stainless steelearth/ground stud assembly enablesrapid and reliable protective earth/ground connection Bolted cover andpadlockable cover alsoavailableIntegral drainage channel Integral drainage channel preventsliquids or other solid contaminantsfrom running in our falling intothe enclosure when the door isopenedMounted on the side of the enclosurefor ease of access Minimizes gasket pathcontaminationDWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton763

Ex-Cell stainless steel andpainted steel enclosuresCl. I, Div. 2, Groups A, B, C, DECl. I, Zone 1Type 3S, 4, 4XIP66High performance, high reliability enclosuresfor global applicationsIECEx/ATEXTR-CU/EAC2EOrdering information:Catalog numbers on following page are for stainless steel enclosureswith one gland plate.Ex-Cell enclosures are available in a variety of materials andconfigurations. To customize, utilize the part number example below:Part number exampleXLVS10906051BXLVS1Enclosure typeXLV2EXLHXLEXLFS2PS1SizeSee available sizes on following pagesStandardenclosure;European versionwith horizontallugs0No gland plates1One gland plate (bottom only) (standard 3mm thick)2Two gland plates (top and bottom) (standard 3mm thick)3Three gland plates (bottom and sides) (standard 3mmthick)Eagle enclosurewith sloping topFlush mountenclosureElectro-polished316L stainlesssteel (standard)Electro-polished304 stainlesssteelPainted mildsteel* (UL50 only,not ATEX or IECExrated)P3Painted* 316Lstainless steelP4Painted* 304stainless steelBETemperature rangeStandardenclosure; NorthAmerican versionwith vertical lugsMaterialS1090605BLANKNumber of gland platesE4Four gland plates (top, bottom and sides) (standard 3mmthick)5One gland plate (bottom only) (6mm thick)6Two gland plates (top and bottom) (6mm thick)7Three gland plates (bottom and sides) (6mm thick)8Four gland plates (top, bottom and sides) (6mm angeDHXOptional padlockhaspBLANKNoneHPadlock haspMaterial thicknessBLANKOptional documentholderStandard materialthicknessXAll 1.5mm thicknessBLANKNoneYAll 2.0mm thicknessZAll 3.0mm thicknessDStainless steeldocumentholderICover fixing optionsBLANKStandard left hinged and quarter turn lockFBHinged and boltedGBBFully boltedGCHContinuous hingeCCCaptive clamps and hinged and boltedGHSee Accessories section to order the following: locking coverhardware, ground stud kits, stand-off pillars, drawing pockets,etc.EWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.FXLV type has slot shaped quarter turn lock; XLH type has double bit quarter turn lock.GMaximum enclosure width is XLH****50 or XLV****20 for this option.H'CC' option only available on one and two gland plates enclosures.INot available on enclosures where the width is equal to 203mm (8") and smaller.*Painted versions only available on demand.764www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton

Ex-Cell stainless steel andpainted steel enclosuresHigh performance, high reliability enclosuresfor global applicationsCl. I, Div. 2, Groups A, B, C, DJCl. I, Zone 1Type 3S, 4, 4XIP66IECEx/ATEXTR-CU/EAC2EMounting information:Depth(See Ordering information section for dimensions)NOTE: Does not include mounting feet center(horizontal)Vertical mountingHorizontal mountingJWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton765

Ex-Cell stainless steel andpainted steel enclosuresHigh performance, high reliability enclosuresfor global applicationsCl. I, Div. 2, Groups A, B, C, DKCl. I, Zone 1Type 3S, 4, 4XIP66IECEx/ATEXTR-CU/EAC2EOrdering information (continued):2EXLV enclosures with vertical mounting feetEnclosure size(H x W x D) (in.)9x6x510 x 8 x 410 x 8 x 610 x 10 x 612 x 10 x 512 x 8 x 612 x 10 x 612 x 12 x 612 x 12 x 812 x 12 x 1016 x 12 x 616 x 12 x 816 x 12 x 1016 x 14 x 816 x 16 x 616 x 16 x 816 x 16 x 1016 x 16 x 1216 x 20 x 616 x 20 x 816 x 20 x 1016 x 20 x 1220 x 16 x 620 x 16 x 820 x 16 x 1020 x 16 x 1220 x 20 x 620 x 20 x 820 x 20 x 1020 x 20 x 1220 x 24 x 820 x 24 x 1020 x 24 x 1224 x 16 x 624 x 16 x 824 x 16 x 1024 x 16 x 1224 x 20 x 624 x 20 x 824 x 20 x 1024 x 20 x 1224 x 24 x 624 x 24 x 824 x 24 x 1024 x 24 x 1224 x 24 x 1624 x 30 x 824 x 30 x 1024 x 30 x 1224 x 30 x 1630 x 20 x 830 x 20 x 1030 x 20 x 1230 x 24 x 830 x 24 x 1030 x 24 x 1230 x 24 x 1630 x 30 x 830 x 30 x 1030 x 30 x 1230 x 30 x 16Cat. #Fixing center vertical(in.)Fixing center horizontal(in.)Cat. #Mounting plateL(zinc coated MP7676KWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.LFits enclosures with both vertical or horizontal mounting feet.766For stainless steel or painted steel mounting plates, contact factory.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton

Ex-Cell stainless steel andpainted steel enclosuresHigh performance, high reliability enclosuresfor global applicationsCl. I, Div. 2, Groups A, B, C, DMCl. I, Zone 1Type 3S, 4, 4XIP66IECEx/ATEXTR-CU/EAC2EOrdering information (continued):XLV enclosures with vertical mounting feet (continued)Cat. #Fixing center vertical(in.)Fixing center horizontal(in.)Cat. #Mounting plateN(zinc coated steel)32 x 24 x 832 x 24 x 1032 x 24 x 1232 x 24 x 1632 x 32 x 832 x 32 x 1032 x 32 x 1232 x 32 x 1636 x 24 x 836 x 24 x 1036 x 24 x 1236 x 24 x 1636 x 30 x 836 x 30 x 1036 x 30 x 1236 x 30 x 1636 x 36 x 836 x 36 x 1036 x 36 x 1236 x 36 x 1640 x 24 x 840 x 24 x 1040 x 24 x 1240 x 24 x 1640 x 32 x 840 x 32 x 1040 x 32 x 1240 x 32 x 1640 x 40 x 840 x 40 x 1040 x 40 x 1240 x 40 x 1648 x 24 x 1048 x 24 x 1248 x 24 x 1648 x 32 x 1048 x 32 x 1248 x 32 x 1648 x 36 x 1048 x 36 x 1248 x 36 x 1648 x 40 x 1248 x 40 x 1648 x 48 x 1248 x 48 x 1660 x 36 x 1260 x 36 x 1663 x 48 x HZTMP15290XLHZTMP1601202EEnclosure size(H x W x D) (in.)MWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.NFits enclosures with both vertical or horizontal mounting feet.For stainless steel or painted steel mounting plates, contact factory.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton767

Ex-Cell stainless steel andpainted steel enclosuresHigh performance, high reliability enclosuresfor global applicationsCl. I, Div. 2, Groups A, B, C, DOCl. I, Zone 1Type 3S, 4, 4XIP66IECEx/ATEXTR-CU/EAC2EOrdering information (continued):2EXLH enclosures with horizontal mounting feetEnclosure size(H x W x D) (mm)229 x 152 x 127260 x 203 x 100260 x 203 x 152260 x 260 x 152305 x 260 x 127305 x 203 x 152305 x 260 x 152305 x 305 x 152305 x 305 x 203305 x 305 x 254406 x 305 x 152406 x 305 x 203406 x 305 x 254406 x 355 x 203406 x 406 x 152406 x 406 x 203406 x 406 x 254406 x 406 x 300406 x 508 x 152406 x 508 x 203406 x 508 x 254406 x 508 x 300508 x 406 x 152508 x 406 x 203508 x 406 x 254508 x 406 x 300508 x 508 x 152508 x 508 x 203508 x 508 x 254508 x 508 x 300508 x 610 x 203508 x 610 x 254508 x 610 x 300610 x 406 x 152610 x 406 x 203610 x 406 x 254610 x 406 x 300610 x 508 x 152610 x 508 x 203610 x 508 x 254610 x 508 x 300610 x 610 x 152610 x 610 x 203610 x 610 x 254610 x 610 x 300610 x 610 x 400610 x 762 x 203610 x 762 x 254610 x 762 x 300610 x 762 x 400762 x 508 x 203762 x 508 x 254762 x 508 x 300762 x 610 x 203762 x 610 x 254762 x 610 x 300762 x 610 x 400762 x 762 x 203762 x 762 x 254762 x 762 x 300762 x 762 x 400Cat. #Fixing center vertical(mm)Fixing center horizontal(mm)Cat. #Mounting plateP(zinc coated 676XLHZTMP7676XLHZTMP7676OWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.PFits enclosures with both vertical or horizontal mounting feet.768For stainless steel or painted steel mounting plates, contact factory.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton

Ex-Cell stainless steel andpainted steel enclosuresHigh performance, high reliability enclosuresfor global applicationsCl. I, Div. 2, Groups A, B, C, DQCl. I, Zone 1Type 3S, 4, 4XIP66IECEx/ATEXTR-CU/EAC2EOrdering information (continued):XLH enclosures with horizontal mounting feet (continued)800 x 610 x 203800 x 610 x 250800 x 610 x 300800 x 610 x 400800 x 800 x 203800 x 800 x 250800 x 800 x 300800 x 800 x 400914 x 610 x 203914 x 610 x 250914 x 610 x 300914 x 610 x 400914 x 762 x 203914 x 762 x 250914 x 762 x 300914 x 762 x 400914 x 914 x 203914 x 914 x 250914 x 914 x 300914 x 914 x 4001000 x 610 x 2031000 x 610 x 2501000 x 610 x 3001000 x 610 x 4001000 x 800 x 2031000 x 800 x 2501000 x 800 x 3001000 x 800 x 4001000 x 1000 x 2031000 x 1000 x 2501000 x 1000 x 3001000 x 1000 x 4001200 x 610 x 2501200 x 610 x 3001200 x 610 x 4001200 x 800 x 2501200 x 800 x 3001200 x 800 x 4001200 x 914 x 2501200 x 914 x 3001200 x 914 x 4001200 x 1000 x 3001200 x 1000 x 4001200 x 1200 x 3001200 x 1200 x 4001524 x 914 x 3001524 x 914 x 4001600 x 1200 x 400Cat. #Fixing center vertical(mm)Fixing center horizontal(mm)Cat. #Mounting plateR(zinc coated MP15290XLHZTMP15290XLHZTMP1601202EEnclosure size(H x W x D) (mm)QWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.RFits enclosures with both vertical or horizontal mounting feet.For stainless steel or painted steel mounting plates, contact factory.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton769

Ex-Cell stainless steelenclosuresCl. I, Div. 2, Groups A, B, C, DSCl. I, Zone 1Type 3S, 4, 4XIP66High performance, high reliability enclosuresfor global applicationsOptions:2E(Available with Ex-Cell standardand large enclosures only)Padlockable hasp (to order, add suffix 'H'to end of catalog number): Provides a secondary means of securityand safety Manufactured from the same materialgrade as the enclosureDrawing pockets: Stainless steel holders for engineeringdrawings can be installed at the factory(to order, add suffix 'D' to end of catalognumber) Plastic document holders may be orderedseparately:- Catalog number: SHS953324 (A4/lettersize orange plastic, self-adhesive)T- Catalog number: SHS953325 (A5 clearplastic)U- Catalog number: SHS953326 (A6transparent plastic bonded)V Custom stainless steel options available(contact factory)Extended temperature range siliconegasket: Provides a service temperature of -60ºC to 135ºC To order, add suffix 'E' to end of catalognumberSun shield and rain/deluge canopy(contact factory): Can be retrofitted to the enclosure asrequired using existing fixing positionsID tag – label and bracket (contactfactory): Provides an effective solution for labelingenclosure assemblies with ID tag labelsContinuous hinge (to order, add suffix'CH' to end of catalog number): Maintains door alignment by distributingopen and close force along the entirelength of the door Provides greater strength and support forlarger door Removable pin allows cover to be easilyremoved from enclosure Not available with painted finish Not available with UL certificationIECEx/ATEXTR-CU/EAC2EAccessories (orderedseparately):Locking cover hardwareCat. #ENXL0011ENXL0010QBXLKWKIQBXLKPADSlot shape (standard with XLV)Type(see images at right)Slot shapeDouble bit shapeWing knob insert withstandard keyWL padlockable handle 10mmXDouble bit shape (standard with XLH)Ground stud kitCat. #TypeENK10738PM10 stainless steelWing knob with standard keyWStand-off pillarsCat. 00.801.20Breather/drainsCat. #TypeBD3S1M20 Ex e IP66 stainless steel(Raxton CV)BD3NPM20 Ex e IP66 nickel-platedbrass (Raxton CV)L padlockable handle 10mmXStand-off pillarsMounting plates (sub-plates): Zinc coated steel mounting plates arestandard (see catalog numbers onprevious pages) Stainless steel or painted steel mountingplates are available (contact factory)Captive cover clamps: Available with stainless steel captive coverclamps (to order, add suffix 'CC' to end ofcatalog number)Tag label holder: Available (contact factory)770SWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements. These enclosures are NOT explosionproof and will NOT contain an explosion. Installation of arcing andsparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.TFor sizes 406 x 406mm (16" x 16") and larger.UFor sizes 406 x 305mm (16" x 12") and larger.VFor sizes 305 x 305mm (12" x 12") and larger.WUL only, IP44.XUL only, IP54.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton

Ex-Cell sloped andflush mount enclosuresHigh performance, high reliability enclosuresfor global applicationsCl. I, Div. 2, Groups A, B, C, DACl. I, Zone 1Type 3S, 4, 4XIP66IECEx/ATEXTR-CU/EAC2ESloped eagle enclosuresApplications: Ideal for highway, DOT, transportation,pharmaceutical and telecommunicationsapplicationsFeatures: Water shedding design for verticalmounted applications protects criticalelectronics and instrumentation Electro-polished stainless steel offershigher corrosion resistance than brushedstainless steel Available with 0 or 1 gland plateCertifications andcompliances: Class I, Division 2, Groups A, B, C, DA;Class I, Zone 1 cULus to UL50/C22.2 No. 94-M91 UL Listed E115376 (Ordinary Location) Type 3S, 4 – painted mild steel†; Type 4X/IP66 – stainless steel ATEX and IECEx component certificates(BAS 15ATEX0099U and IECEXBAS15.0071U) 2G Ex eb IIC Gb or 2D Ex tb IIIC Db TR-CU and EAC certifiedOrdering information:Imperial sizing (in.)Metric sizing (mm)HeightWidthDepthCat. . #Flush mount enclosuresApplications: Ideal for vertical mounting (wall) in apharmaceutical or clean room application;or horizontal mounting (ceiling) in aplenum applicationFeatures: Electro-polished stainless steel offershigher corrosion resistance than brushedstainless steelCertifications andcompliances: Class I, Division 2, Groups A, B, C, DA;Class I, Zone 1 cULus to UL50/C22.2 No. 94-M91 UL Listed E115376 (Ordinary Location) Type 3S, 4 – painted mild steel†; Type 4X/IP66 – stainless steel ATEX and IECEx component certificates(BAS 15ATEX0099U and IECEXBAS15.0071U) 2G Ex eb IIC Gb or 2D Ex tb IIIC Db TR-CU and EAC certifiedOrdering information:Imperial sizing (in.)Metric sizing (mm)Cat. #HeightWidthDepthCat. 05406127152152152AWhen terminal blocks or approved Class I, Division 2 devices are installed within the enclosure in accordance with NEC/CEC requirements.These enclosures are NOT explosionproofand will NOT contain an explosion. Installation of arcing and sparking devices which are not Class I, Division 2 rated or higher is NOT PERMITTED.**Designate material. S1 316L stainless steel; S2 304 stainless steel; PS painted steel (UL50 only, not ATEX or IECEx rated).*Designate 0 or 1 gland plate.†Painted versions only available on demand.www.crouse-hinds.comUS: 1-866-764-5454CAN: 1-800-265-0502Copyright 2021 Eaton771

Single door enclosures up to 63” x 48” x 16” (1600 x 1200 x 400mm) Flush mount enclosures Eagle enclosures with a sloped water shedding design Ex-Cell-T / XL-T terminal boxes: Ex-Cell enclosures are available assembled as custom configured and certified

Related Documents:

Eaton Char-Lynn 4000 Series 10 Eaton Char-Lynn 6000 Series 11 Eaton Char-Lynn 10,000 Series 12 Eaton Char-Lynn Spares 13 Eaton Xcel XLH Series 15 Eaton Xcel XLS Series 16 Eaton Xcel XL2 Series 17 Eaton Xcel Spares 18 Eaton Char-

Eaton 15284 Beltsville, MD Eaton 02750 Bethel, CT Eaton 97484, 16780 Glenolden, PA Eaton 09790, 17472, 72121 Grand Rapids, MI Eaton 86090 Irvine, CA Eaton 62983, 90166 Jackson, MS Eaton 99643, 76050, 52906 Los Angeles, CA Eaton 77842 Warwick, RI Essex Cryogenics 19062 Saint Louis, MO Essex Industries 0HFY6 Saint Louis, MO Extant 22830 Melbourne .

Bruksanvisning för bilstereo . Bruksanvisning for bilstereo . Instrukcja obsługi samochodowego odtwarzacza stereo . Operating Instructions for Car Stereo . 610-104 . SV . Bruksanvisning i original

4 EATON PERFORMANCE PRODUCTS Differential Application Guide Eaton ELocker Eaton Detroit Truetrac Eaton Posi. No matter your application, Eaton Performance has a differential to meet your needs. Product On Road. Off-Road Drag Racing; Circle Track Restoration: Street and Muscle

For more information visit: www.eaton.com IB01602009E Instruction Booklet Page4 Effective: January 2020 ATC-300 Automatic Transfer Switch Controller 1.5.2 Standard and Optional Features A variety of programmable features are available with the ATC 300 Controller to meet a File Size: 936KBPage Count: 28Explore furtherO & M Manual for the EATON ATC-300 Automatic Transfer .www.eaton.comAll Product Manuals - Eatontaa-ups.eaton.comOperators Manual ASCO SERIES 300 Automatic Transfer .www.ascopower.comEaton automatic transfer switch brochurewww.eaton.comATC-300 Power Series Transfer Switchwww.generac.comRecommended to you based on what's popular Feedback

10 tips och tricks för att lyckas med ert sap-projekt 20 SAPSANYTT 2/2015 De flesta projektledare känner säkert till Cobb’s paradox. Martin Cobb verkade som CIO för sekretariatet för Treasury Board of Canada 1995 då han ställde frågan

service i Norge och Finland drivs inom ramen för ett enskilt företag (NRK. 1 och Yleisradio), fin ns det i Sverige tre: Ett för tv (Sveriges Television , SVT ), ett för radio (Sveriges Radio , SR ) och ett för utbildnings program (Sveriges Utbildningsradio, UR, vilket till följd av sin begränsade storlek inte återfinns bland de 25 största

Hotell För hotell anges de tre klasserna A/B, C och D. Det betyder att den "normala" standarden C är acceptabel men att motiven för en högre standard är starka. Ljudklass C motsvarar de tidigare normkraven för hotell, ljudklass A/B motsvarar kraven för moderna hotell med hög standard och ljudklass D kan användas vid