Solenoid Valves- D03 & D05 - Hyvair Corp.

2y ago
16 Views
2 Downloads
2.48 MB
9 Pages
Last View : 2m ago
Last Download : 3m ago
Upload by : Farrah Jaffe
Transcription

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESFeaturesSeries 35High FlowHigh PressureDirectional ValvesD05SD DIN TypeD05S Electrical Box TypeD03SD DIN TypeD03S Electrical Box TypeD03SDS Deutsch Socket(D03 Only)D03SL Lead Wire Type(D05SL Lead Wire Type also available)NFPA SIZE: D03 & D051. High Flow/ High Pressure: Up to 25 gpm (D03) and40 gpm (D05)/ 5000 psi working pressure*.2. Oil Immersed, Quiet Solenoid Design: Moving coreimmersed in hydraulic oil provides quiet operation.3. High Tank Port Pressure: Up to 3000 psi tank portback pressure (Check each spool type for max. allowable).4. Twin Tank Line Design: Upper and lower tank linechannels (Double Loop) greatly reduces pressure drop.5. Wiring: Electrical box with indicator lights and terminalstrip connection standard. DIN connector provided standard on DIN style coils. (Connectors may optionally besupplied with lights.)6. Hydraulic/ Electric Shockless: Valve coils availableelectric shockless (rectified)- reducing voltages spikes,extending relay contact life, and providing even quieteroperation. Spool shifting time is increased up to fourtimes by metering the oil in the core tube. Option F(Electrical Box version only)7. Maintenance: Indicator lamps to diagnose connection;Plug-in coils provide easy changing without disturbingwiring.8. High Reliability: Valve designed to last 30 millionspool shifts under proper use.9. Bolt Kit included with valve standard*Some spools rated less- check max. pressures and flows chartInternal StructureNFPA D03NFPA D05D03 with “Double Loop”High Flow DesignD05 with “Double Loop”High Flow Design5 Channel 6 Tooth DesignElectrical box with indicator lights and terminalstrip connection standard.Electrical boxes shown with optional rectifiers. (Code X)31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESSpecificationsNFPA SIZE: D03 & D0531341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESSpecificationsNFPA SIZE: D03 & D05Symbols31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESNFPA SIZE: D03 & D05Common 115 VAC mmon ConfigurationsElectrical BoxDin CoilAD03S-1AY-115A-35 -35TD03S-3A-115A-35D05S-3A-115A-35AD03S-1 D03S-5 -D03SD-1 D03SD-5 -D03S-2 D03S-3A-D03SD-2 D03SD-3A-D05S-1 D05S-5 -D05SD-1 D05SD-5 -D05S-2 D05S-3A-D05SD-2 D05SD-3A-D0 -SP- -DCSingle Spade ConnectorNow AvailableOrdering InformationD03 S-2 B -115 A-35SizeD03D05Code ActuatorSolenoidSSoln. w/SDDin CoilHydraulicSF ShocklessDeutschSDSSocket(D03 only)Code1235ConfigurationSingle solenoid 2 positionspring offsetDouble solenoid 3 positionspring centeredDouble solenoid 2 positionno center, detentedSingle solenoid 2 positionspring centeredSpecify: (special order)SL for lead wireSP for single spade plugThreadTorqueSpool FunctionP to A, B to TP to A, B to TBAll Ports BlockedCA & B BlockedP to TA & B to TP BlockedAll Ports OpenA to TP & B BlockedP to A & B,T BlockedFHKMounting Bolt/ O’Ring InformationSizeCodeAAYO’RingUS Metricin-lbs/ (Nm)D0310 - 24 UNC40 - 45 (4.5 - 5.1)D051/4 - 20 UNC 105 - 110 (11.9 - 12.4) 11.8mm I.D. x 2.4mm C.S.9mm I.D. x 2mm C.S.TA spool is closed in transitionAY spool is open in Notes:Lights included standard onelectrical box style.Code “R” (reversed)added behind spoolcode for flow suppliedopposite of standard.Codes 1AR & 1AYR: spool & coil reversedCodes 2 R & 3AR: electrical box reversedCode 5 R: coil provided on reversed b side31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESNFPA SIZE: D03 & D05Electrical InformationD03Solenoid Coil Specifications115V-AC230V-AC115V-RAC (rectified)230V-RAC (rectified)12V-DC24V-DCCoil Model D03S (Elect. D2Coil Model D03SD -D2DC12DC241.25Solenoid VoltageApplied VoltageAC110Frequency (Hz)5060Starting Current (A)2.22.0AC120602.2Holding Current (A) 0.54 0.41Holding Power (W)250.4722Permissible Voltage Range (V)AC22050601.11.0AC120AC22050 / 60AC24050 / 221.6-26.422180-24080-120AC110600.25 0.192528AC24080-130Insulation Resistance (M )180-250100 or above (500V)D05Solenoid Coil Specifications115V-AC230V-AC115V-RAC (rectified)230V-RAC (rectified)12V-DC24V-DCCoil Model D05S (Elect. D2Coil Model D05SD -D2DC12DC241.5Solenoid VoltageApplied 5.54.65.02.72.31.10.861.00.52 0.8-13.221.6-26.4Frequency (Hz)50Starting Current (A)Holding Current (A)Holding Power (W)Permissible Voltage Range (V)80-12050 / 6050 / 602.534180-240Insulation Resistance (M )Other Configurations60AC11080-130180-250100 or above (500V)Examples of Code “R”- Reversed(symbols shown in simplified SD-5BR(standard)(no change to DIN coil valve, electricalbox flipped for opposite coil markings)(standard)(coil supplied reversed from normalposition & spool reversed)(standard)(right or “b” coil side ofvalve provided)(symbol shown blocked during valve transition only)Notes: DIN Coils manufactured to accept standard 3 pin DIN 43 650 and ISO 4400 connectors. AC Coils are rated for both 50/60Hz (rewiring not required) DC coils are not polarity sensitive Rectifier is supplied: in the electrical box- D03S, D05S in the coil (internal)- D03SD, D05SD Hydraulic shockless AC valves are always supplied with rectifier. Hydraulic shockless valves will not operate as shockless until the tank line has become filled with oil- occurs automatically after thefirst few cycles. Mounting valve below the reservoir oil level or using check valve ensures that the tank line remains filled. Do not supply electrical power to the AC coils unless the coil is mounted on the valve. Do not exceed voltage specifications shown above. Electrical power should be maintained on detented valves (spool code 3A). Detent only maintains start-up position of the valve.31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESNFPA SIZE: D03 & D05Pressure Drop CurvesEarth TerminalIndicating LightCommon JumperCommon TerminalSolenoid b TerminalSolenoid a TerminalIndicating LightEarth TerminalSolenoid b TerminalIndicating LightCommon TerminalTerminal supplied on“a” (right side) for code“R” reversed coil valveEarth Terminal31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESNFPA SIZE: D03 & D05Electrical Box TypeD03SD03SFDimensional DataAC SolenoidAC SolenoidSOL bSOL a1.48SOL b0.22 Dia.Units: InchesMounting: (4) 10-24 SHCS x 1-3/4”Torque 40-45 in-lbs4.044.048.072.601.654.045.69DC Solenoid(2) 1/2” NPTAC Solenoid2.80Indicator Light SOL bSOL b1.481.873.48SOL a1.000.30 Dia.Indicator Light SOL a0.22 Dia.1.814.521.66Push pin for manual operation9.04AC SolenoidAC Solenoid1.88DIN TypeD03SDSOL aSOL b1.48SOL b4.040.22 Dia.Units: Inches4.042.60Mounting: (4) 10-24 SHCS x 1-3/4”Torque 40-45 in-lbs4.048.071.54DC Solenoid5.571.88SOL b1.48SOL a3.581.873.13AC Solenoid1.000.30 Dia.0.22 Dia.4.521.811.549.04Push pin for manual operationDC SolenoidSOL bSOL a1.48Lead Wire TypeD03SLUnits: InchesMounting: (4) 10-24 SHCS x 1-3/4”Torque 40-45 in-lbs0.22 Dia.4.521.549.0431341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESNFPA SIZE: D03 & D05Electrical Box TypeD05SD05SFDimensional DataAC SolenoidAC Solenoid0.43 Dia.Indicator Light SOL bSOL bSOL aUnits: InchesMounting: (4) 1/4-20 SHCS x 1-1/2”Torque 105-110 in-lbsIndicator Light SOL a4.714.719.43(2) 1/2” NPTAC SolenoidSOL bSOL b1.424.292.683.60DC SolenoidSOL a1.021.020.27 Dia.2.760.27 Dia.3.66Push pin for manual operation5.242.284.712.2810.487.00DIN TypeD05SDAC SolenoidAC Solenoid0.43 Dia.SOL aSOL bUnits: InchesMounting: (4) 1/4-20 SHCS x 1-1/2”Torque 105-110 in-lbs4.714.719.43AC Solenoid2.524.53SOL bSOL b1.422.684.07DC SolenoidSOL a1.022.761.020.27 Dia.0.27 Dia.3.66Push pin for manual operation2.285.242.284.7110.487.00DC SolenoidLead Wire TypeD05SLSOL aSOL bUnits: Inches1.02Mounting: (4) 1/4-20 SHCS x 1-1/2”Torque 105-110 in-lbs0.27 Dia.5.622.2811.2431341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVESD03 & D05 SERIES 35- SOLENOID VALVESNFPA SIZE: D03 & D05Parts Breakdown D03S/ D03SD/ D03SL Series 35Parts Breakdown D03S/ D03SD/ D03SL Series 351) Solenoid Nut2) O-Ring3) Coil For Elect. Box Type)4) Armature (Core Tube)5) O-Ring6) Push Pin7) Spring8) Retainer9) Washer10) Spool (3 position)11) O-Ring12) Body13) O-Ring14) Concave Pin15) Spool (2 position detent)16) O-Ring17) Hex Plug18) Spring19) Spool (2 pos. single coil)20) Body21) Retainer22) Electrical Box23) Screw24) Acrylic Cover25) Nameplate (Elect. Box)26) Screw27) Nameplate (Non-Box Type)28) Screw29) Coil (For DIN Type)30) Connector31) Screw32) Coil (For Lead Wire Type)Parts Breakdown D05S/ D05SD/ D05SL Series 35Parts Breakdown D05S/ D05SD/ D05SL Series 351) Solenoid Nut2) O-Ring3) Coil For Elect. Box Type)4) O-Ring5) Armature (Core Tube)6) O-Ring7) Push Pin8) Spring9) Retainer10) Spool (3 position)11) Body12) O-Ring13) Concave Pin14) Spool (2 position detent)15) O-Ring16) Hex Plug17) Spool (2 pos. single coil)18) Retainer19) Joint Box20) Joint Box Screw21) Acrylic Cover22) Nameplate23) Screw24) Nameplate (Non-Box Type)25) Screw26) Coil (For DIN Type)27) Connector28) Screw29) Coil (For Lead Wire Type)31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

SOLENOID VALVES D03 & D05 SERIES 35- SOLENOID VALVES NFPA SIZE: D03 & D05 Series 35 High Flow High Pressure Directional Valves 31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com

Related Documents:

vad03m air actuated, direct operated d03/03 48 - 53 va12m air actuated, direct operated d05/05 54 - 57 vad08m air actuated, pilot operated d08/08 58 - 62 vc12m cam actuated, direct operated d05/05 63 - 65 model series operated size -nfpa/iso page no. vs5m solenoid actuated, direct operated d03/03 66 - 70

A BUCHER HYDRAULICS COMPANY MT & T Series Power Units . 1 and Strainer Options: · Water / Oil heat exchangers · Air / Oil heat exchangers · Pressure switches · D03 and D05 directional control valves · Subplate mounted D03 and D05 stack valves: Cross port relief Port relief .

LVM09/090 2/3 port direct operated solenoid Cv 0.018 139 LVM10/100 2/3 port direct operated solenoid Cv 0.03 0.04 139 LVM15/150 & -20/200 2/3 port direct operated solenoid valve Cv 0.015 0.065 140 VDW10, -20 & -30 2/2 solenoid Cv 0.03 0.44 141 VDW200 & -300 3/2 solenoid Cv 0.03 0.44 142 VCA solenoid valve Cv 0.33 2.1 143 N

Series 35- Solenoid Pilot Operated Directional Valves 31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com CROSS SECTION CROSS SECTION DRAWING 1) Main vVal e with Housing 2) Main Control Spool 3.1) Return Spring 3.2) Return Spring 4) Pilovet Val 5.1) Solenoid 5.2) Solenoid 6) Spring Chamber

S - 5,20 bar (75 psi) check Solenoid Energization Identity Blank - Standard arrangement for ANSI B93.9 (i.e. energize solenoid A to follow flow P to A). V - Solenoid identification determined by position of solenoid (i.e. solenoid A at port A end/solenoid B at port B end). Note 4 and 8 type spools are always V. Solenoid

Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled Pilot Operated Directional Valves These valves are composed of a solenoid operated pilot valve and a pilot operated slave valve. When a solenoid is energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in the .

Modular/ Stackable Valves 31341 Friendship Drive, Magnolia, TX 77355 Tel.: 281-259-7768 Fax: 281-259-7249 www.hyvair.com INDUSTRIAL FLUID POWER COMPONENTS

CUERPOS Y ROSTROS Alfredo López Austín lnstituto de Investigaciones Antropológicas - UNAM En una reseña allibro Literatura náhuatl de Arnos Segala,r Miguel León-Portilla se refiere a dos afi¡maciones que aparecen en mi li- bro Cuerpo humano e ideología:z en una ocasión para criticar mi interpretación filológica de la palabra tlacatl y en otra para contes-