CA2400Generator StockProducts Catalog Portables Towables and Light Towers Commercial/Industrial Standby Mod Express Effective Date:May 19, 2013

Table of ContentsUL2200 Listed Stock Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iBaldor Generator Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Diesel Industrial Quality Portable Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Receptacle Reference Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Towable Generators and Light Towers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Towable Generator and Light Tower Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Industrial Towable Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Industrial Towable Generators Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Industrial Towable Generators Accessories – Mod Express Only . . . . . . . . . . . . . . . . . . . . . . . .9IDLC Industrial Standby Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10IDLC Generator Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12IDLC Generator Accessories – Mod Express Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13GLC Industrial Standby Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14GLC Engine Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15GLC Generator Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16GLC Generator Accessories – Mod Express Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Generator – Mod Express Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Transfer Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Generator Selection Guide and Electrical Formulas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20Baldor Sales Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Back CoverUL2200 Listed Stock GeneratorsAll stock diesel and gaseous stationary gensets are designed and built to meet stringent UL2200standards. Both Industrial Diesel Liquid Cooled (IDLC) and Gaseous Liquid Cooled (GLC) stockconfigurations are UL2200 approved, open gensets, without an exhaust silencer. UL listed options andaccessories are available for both IDLC's and GLC's. These options are installed when specified at thetime of order. You can find individual accessories along with our UL2200 approved in-stock gensets onpages 11-17.Enclosed StationaryiOpen Stationary

Diesel Industrial Quality Portable GeneratorsBaldor’s diesel portables feature the rugged Hatz diesel engine, known worldwide as a superior air-cooled diesel engine.Baldor generators are manufactured to exceed industrial specifications using high quality components. Electric Start Brushless Alternator Hour Meter - Helps to track and schedule routine maintenance Voltage - 120/240 Volt Single Phase Wheel Kit - Available as accessoryDesigned to operate on diesel fuel. Provides auxiliarypower for many applications where diesel fuel is available.Suitable for commercial, construction, and farm applications.DG3ECatalogNumber ltsMult.Sym.Approx.ShippingWeight (lbs)DG3E330030002.75 Gal.Hatz5.5120/240 VAC 3,582PG196DG6E600055004.6 Gal.Hatz9.9120/240 VAC4,995PG273NOTE: ➀ Batteries are not included or available on any Electric Start Models.Baldor reserves the right to implement specifications or design changes without notice.WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.Follow local and national electrical codes for proper installation.Receptacle Reference Drawings2ListPrice

Baldor Industrial Quality Portable GeneratorsPortable Diesel ModelDG3EDG6ESwitchless Full Pow’RstdstdAC VoltmeterstdstdHourmeterstdstdLow Oil ShutdownstdstdSpark Arrestor MufflerstdstdExtended Run Fuel TankstdstdTubular Roll CagestdstdNeoprene IsolatorsstdstdFocal Vibration Systemstdstd3-Year WarrantystdstdEngine ModelHatz 1B30Hatz 1B405.59.9FeaturesHorsepowerCylinder11Displacement - CC346461.9Starting Systems ➀12 Volt with Recoil12 Volt with Recoil33006000RatingMax RatingRated30005500Volts120/240 VAC120/240 VACAmps25/12.545.8/22.960 Hz60 Hz7476Straight (520R GFCI) 120V, 20A, Duplex12Twist Lock (L530R) 120V, 30A11Twist Lock (L1420R) 120/240V, 20A1—Twist Lock (L1430R) 120/240V, 30A—1FrequencydBA (Avg) @ 7 metersReceptaclesFuel SystemFuel Capacity (U.S. Gallons)2.754.6Operational Run Time Full Load5.4 hr4.6 hrOperational Run Time Half Load9 hr6 eight21.75”23.75”Weight (Net Dry)172 lbs246 lbsNOTE: ➀ Batteries are not included or available on any Electric Start Models.Baldor reserves the right to implement specifications or design changes without notice.WARNING: Do not connect generator to any building’s electrical system unless a disconnect switch has been installed.Follow local and national electrical codes for proper installation.Portable AccessoriesCatalogNumberDescriptionPGD22 Wheel Dolly KitFeaturesTwo 10” Pneumatic Wheels, Fold Down Handles, Cable StorageHanger, and Mounting HardwareAvailable for ModelsListPriceMult.Sym.Approx.ShippingWeight (lbs)Diesel Models 232G8203

Towable Generatorsand Light TowersApplicationsBaldor Towable Generators and Light Towersare designed and engineered to provide superiorreliability and performance. Each unit has astate-of-the-art digital control, weatherproofreceptacle panel, and meets current emissionrequirements. Baldor Towable Generators andLight Tower can be used for various typesof applications: Construction, Emergency,Industrial, Mining, Civil Engineering, and EventLighting.Standard Features Industrial grade liquid cooled engine. Prototype tested, factory built, and productiontested. Brushless alternator for long life and lowmaintenance. Side mounted weather proof receptacles in arecessed panel on genset models. Two padlockable side doors for easy access togenset controller. Integral fork lift pockets. Highway quality suspension, single axle trailer with front leveling jack, running lights, and lighted license platebracket. Circuit breakers for all receptacles, easily accessible, and mounted internally to genset enclosure. Large internal 50 gallon fuel tank for long run time. Digital controller featuring battery volts, running hours, engine and genset faults. Engine starting battery included.Additional Light Mast Features (standard on TG8LT Light Tower) 4 Powerful 1000 Watt metal halide lamps. Zinc plated 30' 4-section mast with heavy duty winch, rotates 360 for optimum lighting.Towable Generators and Light ym.TG8LTTG8LT-1K8/8120/2401Kubota13.150 12,766LT1400TG10TTG10LT-1K10 / 10120/2401Kubota17.65011,605TG1080TG15TTG15LT-1K15 / 15120/2401Kubota24.35015,605TG1400TG20TTG20LT-1K20 / 20120/2401Kubota35.55017,611TG155018 / 18120/2401TG25TTG25LT-1K25 / 20120/2083Kubota35.55021,038TG165025 / 20277/4803NOTE: TG8LT includes Light Mast and capacitor excited alternator. Baldor reserves the right to implement specifications or design changes without notice.Warning: Do not connect generator to any building's electrical system unless a disconnect switch has been installed.4Approx.ShippingWeight (lbs)

Towable Generators and Light TowersCatalog NumberEngineStandby Output1 ph @ 120/240 Volt (kVA/kW)Amps @ 240 Volt/1 Phase3 ph @ 120/208 Volt (kVA/kW)Amps @ 208 Volt3 ph @ 277/480 Volt (kVA/kW)Amps @ 480 VoltVoltage RegulationGenset Ambient Temp RatingFrequencyTotal Harmonic DistortionFrequency Regulation NL to FLAlternator Temperature RiseAlternator Insulation ClassUnbalanced Load CapabilityLoad Acceptance CapabilityEngine SpecificationsModelCylindersInduction SystemDisplacement, Liter/ Cu. In.Hp @ Rated SpeedRPMBore and StrokeOil Capacity w/ Filter L(Gal)Recommended OilGovernorCoolingCoolant CapacityEPA Emissions LevelBatteryBattery Min. CCAReceptacle Specifications120 Volt 20 Amp Duplex GFCI120/240 Volt 30A NEMA L1430R Twistlock120/240 Volt 50A CS6369 TwistlockController TypeFuel Specifications (Diesel)Fuel Capacity (Gal)Fuel GPH 1/2 Load / Full LoadRun Time 1/2 Load / Full Load (Hrs.)Weights and DimensionsApproximate Shipping Weight (lb.)Towable Dimensions (L x W x TKubota8/833––––5%113 /45 C60 Hz 5%Isochronous150 CClass H20% of Standby Rating100% of Rating inOne Step10 / 1041––––1%113 /45 C60 Hz 5%Isochronous150 CClass H20% of Standby Rating100% of Rating inOne Step20 / 2083––––1%113 /45 C60 Hz 5%Isochronous150 CClass H20% of Standby Rating100% of Rating inOne Step18 / 187525 / 206925 / 20301%113 /45 C60 Hz 5%Isochronous150 CClass H20% of Standby Rating100% of Rating inOne StepD1005-E3BG3Naturally Aspirated1.001 / 61.113.118002.99" x 2.90"5.1(1.35)15W-40MechanicalLiquid5.4 QtTier 412 Vdc525D1305-E3BG3Naturally Aspirated1.261 / 77.017.618003.07" X 3.46"5.7(1.51)15W-40MechanicalLiquid5 QtTier 412 Vdc55015 / 1562––––1%113 /45 C60 Hz 5%Isochronous150 CClass H20% of Standby Rating100% of Rating inOne StepDieselD1703-M-E3BG3Naturally Aspirated1.647 / 100.524.318003.43" x 3.64"5.6(1.48)15W-40ElectricLiquid5 QtInterim Tier 4 Flex ➀12 Vdc750V2403-M-E3BG4Naturally Aspirated2.434 / 148.535.518003.43" x 4.03"9.5(2.51)15W-40ElectricLiquid8 QtInterim Tier 4 Flex ➀12 Vdc750V2403-M-E3BG4Naturally Aspirated2.434 / 148.535.518003.43" x 4.03"9.5(2.51)15W-40ElectricLiquid8 QtInterim Tier 4 Flex ➀12 222Digital500.35 / 0.5142 / 100500.62 / 1.0483 / 48500.79 / 1.3163 / 38501.05 / 1.7547 / 28501.05 / 1.7547 / 281400158" x 54" x 71"1080114" x 54" x 57"1400114" x 54" x 57"1550121" x 54" x 57"1650121" x 54" x 57"➀ Not for use in stationary non-emergency applications.Towable Generators and Light Tower AccessoriesThe following accessories are available to modify the Towable Generator and Light Tower from the stock configuration. The accessoryitems can either be field installed or added at the time of order through our exclusive Baldor ModExpress program.Catalog No.DescriptionFits ModelList PriceMult. SymPLEW12Electric Winch Kit - Replaces manual winch used for horizontal to vertical mast rotation or vertical mastextension. Contains DC motor powered winch with integral raise/lower switch, mounting bracket for eitherlocation, and wiring harness with integral fuse. One kit replaces one manual winch.All Light Mast 1,172G8TGLMTLight Mast Kit – 4-1,000 watt metal halide lamps on a 30 ft telescoping/storable mast.Includes all mounting and electrical hardware along with stabilization outriggers.All TG6,835G8Spare Tire Kit – Full size tire and wheel that fits all TG trailers.All TG336G8TGST14T5

Industrial Towable GeneratorsApplicationsIndustrial towable generators are designed and engineeredfor optimum performance and superior reliability. From theultra quiet sound attenuated enclosures to the state-of-the-artelectronics and controls, these units are engineered to meetthe most rugged conditions. Place the unit at the job site,connect the load and start it up. These full-featured unitsare specially suited for all industrial, commercial and rentalapplications. Units can also be used with an automatictransfer switch for standby applications.TS80TStandard Features Extra Large Access Doors Manual or Automatic Start withStart/Stop/Auto Switch Three Position Switch for Main VoltageSelection Single Phase Receptacles are PoweredDuring All Main Voltage Configurations Voltage Adjust Pot Fuel Water Separator High Water Temperature Shutdown Single Point Lifting Eye Low Oil Pressure Shutdown Illuminated Control Panel Starting Battery Included Alarm HornAdditional Features for TS25 thru TS80 Digital genset controller with Analog Gauges and Meters for engine oil pressure, coolant temp., battery volts, and generator output volts, hertz, ampswith phase select Large integral single wall XLPE fuel tank 2-inch ball hitch coupling on trailered unitsAdditional Features for TS175 thru TS500 Digital genset controller with automatic shutdowns and digital readouts for engine oil pressure, coolant temp., low coolant level, low fuel level, batteryvolts, engine overcrank and overspeed. Large double wall metal fuel tank with integral spill containment basin 3-inch pintle hitch coupling on trailered unitsIndustrial Standby(with or without trailer)CatalogNumberModelNumberkVA/kW@ 240V1 PhasekVA/kW@ 208V3 PhasekVA/kW@ 480/240V3 150/150206/206250/250VAC1 PhaseVAC3 ippingWeight (lbs)John DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn Deere50 Gal.50 Gal.80 Gal.80 Gal.80 Gal.210 Gal.210 Gal.260 Gal.390 Gal.550 Gal. 169/135186/148With 0120/240208/240/480120/240208/240/480Skid Mount Without /148120/240208/240/480John DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn Deere50 Gal.50 Gal.80 Gal.80 Gal.80 Gal.210 Gal.210 180350/280500/400225/180350/280500/400John DeereJohn DeereJohn Deere260 Gal.390 Gal.550 20/240208/240/480208/240/480208/240/480NOTE: Standby ratings for supplying emergency power for the duration of a utility outage. No overload capability for standby rating. Output ratings are specified for 1000feet Altitude above sea level, 77 F Ambient Temperature, Reduce output rating by minus 1% for every 2000 feet above 1000 feet altitude, reduce output rating byminus 1% for ever 20 F above 77 F ambient temperature. Baldor reserves the right to implement specifications or design changes without notice.WARNING: Do not connect generator to any building's electrical system unless a disconnect switch has been installed.Follow local and national electrical codes for proper installation.6

Industrial Towable GeneratorsCatalog S190T/STS225T/STS350T/STS500T/SEngineJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn DeereJohn Deere3 ph @ 480 Volt or 240 350/280500/4003 ph @ 50/280500/4001 ph @ 240 206/206250/250Standby Output(kVA/kW)Prime Output(kVA/kW)3 ph @ 480 Volt or 240 319/255455/3653 ph @ 19/255455/3651 ph @ 240 7/187240/240Voltage - 3 ph 0/240416/440/460/480Voltage - 1 ph /254/277120/127/139240/254/277Voltage Selections3-Phase Power Factor0.80.80.80.80.80.80.80.80.80.8Voltage Frequency60 Hz60 Hz60 Hz60 Hz60 Hz60 Hz60 Hz60 Hz60 Hz60 HzTotal Harmonic Distortion 5% 5% 5% 5% 5% 5% 5% 5% 5% 5%Class HClass HClass HClass HClass HClass HClass HClass HClass HClass H3 ph 480 Volt30455773962252232714216013 ph 240 Volt60901141461924504475418421203Insulation MaterialAmperage (Standby):3 ph 208 TurbochargedCharge AirCoolingTurbochargedCharge AirCoolingTurbochargedCharge AirCoolingTurbochargedCharge AirCoolingTurbochargedCharge AirCoolingTurbochargedCharge AirCoolingTurbochargedCharge AirCoolingTurbochargedCharge 4226341800180018001800180018001800180018001800Bore and Stroke3.4” x 4.1”3.4” x 4.1”3.4” x 4.1”3.4” x 4.1”4.2” x 5.0”4.2” x 5.0”4.2" x 5.00"4.2" x 5.00"4.7" x 5.4"5.2" x 6.5"Oil capacity (with filter)8.5 quarts8.5 quarts7.6 quarts7.6 quarts14.7 quarts34 quarts34 quarts34 quarts39 quarts69 onicElectronic1 ph amperage @ 240V/120VEngine SpecificationsModelCylindersInduction SystemDisplacement, Liter/Cu. In.Hp @ Rated SpeedRPMCoolingEPA Emissions uidLiquidLiquidInterim Tier 4Interim Tier 4Tier 3 Flex ➀Tier 3 Flex ➀Tier 3 Flex ➀Tier 3 Flex ➀Interim Tier 4Tier 3 Flex ➀Tier 3 Flex ➀Interim Tier 46756759259259259259259252 x 9252 x 9252233344444Battery Minimum Cold CrankingAmps (supplied)Receptacle Specifications120 Volt 20 Amp Duplex GFCI120/240 Volt 50 Amp CS6369Twistlock2233344444Two Wire Remote Start CapabilitystdstdstdstdstdstdstdstdstdstdDigital & AnalogDigital & AnalogDigital & AnalogDigital & AnalogDigi

kVA/kW Rating Voltage Phase Engine Engine Hp Fuel Capacity (Gal) List Price Mult. Sym. Approx. Shipping . Alternator Temperature Rise 150 C 150 C 150 C 150 C 150 C . Contains DC motor powered winch with integral raise/lower switch, mounting bracket for either

Related Documents:

Viking Gear Pumps Finish Thompson Drum & Centrifugal Pumps Micropump Gear Pumps Hydra-Cell High Pressure Diaphragm Pumps Ismatec Peristaltic Pumps Liqui o Gear Pumps Codip Air Operated PTFE Diaphragm Pumps HNP Gear Pumps M Pumps, Centrifugal, Turbine and Vane Pumps Fluid Metering Piston Pumps.

CRANE DEMING HAYWARD TYLER PYLES WILSON SNYDER . DURCO IMO SIMS ZOELLER TYPES OF PUMPS REPAIRED BY KENNEDY INDUSTRIES, INC.: Boiler Feed Pumps Piston Pumps Horizontal Split Case Pumps Submersible Pumps Vertical Turbine Pumps End Suction Pumps Circulating Pumps Sewage Pumps Vacuum Pumps Amine Pumps Slurry and Abrasive .

Oilgear engineers will be there, ready to help you with the education, field service, parts and repairs . Table of Contents Pvm Pumps page 3 PvWJ Pumps page page4 PvWh Pumps page page5 PvWW Pumps page 6 PvWc Pumps page page7 Pvg Pumps page 8 PvK Pumps page page9 Pvv Pumps page 10 PfBA Pumps page 11 PfBK Pumps 12 . 130 7.94 130,2 1500 103,4 .

Mar 06, 2019 · Grundfos Efficiency Upgrade Guide. Table of Contents Page # Description: 3: Taco 00 Pumps: 5; Taco 1600 Pumps 7: Taco 1400/2400 Pumps 9: Taco 100 Pumps 11: Taco 00e Pumps 13: Taco Veridian Pumps 15: B&G 60 Pumps 17: B&G PL Pumps 19: B&G NRF Pumps 21: B&G 3-Piece P

GEAR PUMPS MOTORS & FLOW DIVIDERS we www.catford.com.au email salescatford.com.au tel 0418 641 566 117 Vivoil Group 1 Pumps 120 Vivoil Group 2 Pumps 124 Vivoil Group 3 Pumps 130 Multiple Pump Nomenclature 134 Group 1 Pumps 136 Group 2 Pumps 137 Group 3 Pumps 139 Log Splitter Pumps 141 Vivoil Group 1 Gear Motors 142 Vivoil Group 2 Gear Motors 145 Vivoil Group 3 Gear Motors 148

Ismatec catalogue provides overview of approximate tubing life Tubing Life. . The UK’s leading pump specialist Viking Gear Pumps Micropump Gear Pumps Hydra-Cell High Pressure Diaphragm Pumps Ismatec Peristaltic Pumps Finish Thompson Drum & Centrifugal Pumps Codip Air Operated PTFE Diaphragm Pumps HNP Gear Pumps M Pumps, Centrifugal,

SR4B Generator Exciter - Remove and Install SMCS - 4454-010 Removal Procedure Remove The Exciter Field and Remove The Exciter Armature 1. Remove the side and rear access panels from the generator. Product: GENERATOR Model: SR4 GENERATOR 5FA Configuration: GENERATOR MOUNTED CONTROL PANEL 5FA00001-UP

of general rough paths. However, in this paper, we will focus on the case where the driving signal is of bounded variation. Following [6] we interpret the whole collection of iterated integrals as a single algebraic object, known as the signature, living in the algebra of formal tensor series. This representation exposes the natural algebraic structure on the signatures of paths induced by the .