Designer Series Undercounter Wine Storage - Sub-Zero

10m ago
4 Views
1 Downloads
637.38 KB
8 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Anton Mixon
Transcription

Designer Series Undercounter Wine Storage Installation Guide Guía de instalación Guide d’installation Guida all’installazione Installationsanleitung Installatiehandleiding 安装指南

Designer Series Undercounter Wine Storage Contents 2 Designer Series Undercounter Wine Storage 3 Opening Dimensions 3 Electrical Requirements 4 Preparation 4 Anti-Tip Bracket 4 90 Door Stop 4 Placement 5 Alignment 5 Door Panel 6 Panel Installation 7 Completion Important Note Product Information To ensure this product is installed and operated as safely and efficiently as possible, take note of the following types of highlighted information throughout this guide: Important product information, including the model and serial number, are listed on the product rating plate. The rating plate is located on the underside of the control panel, on the left. Refer to the illustration below. IMPORTANT NOTE highlights information that is especially important. CAUTION indicates a situation where minor injury or product damage may occur if instructions are not followed. WARNING states a hazard that may cause serious injury or death if precautions are not followed. If service is necessary, contact your authorized Sub-Zero dealer. RATING PLATE Rating plate location 2 English

Site Preparation Opening Dimensions Electrical Requirements DESIGNER SERIES UNDERCOUNTER WINE MODELS The depth of each model is 587 mm. Allow for panel thickness when planning the finished opening depth. A minimum 89 mm finished return is required on all sides of the opening. Framed cabinets require additional finished filler material behind the face frame for a proper installation. Refer to the illustration. 620mm OPENING DEPTH DUAL INSTALLATION W OPENING HEIGHT OPENING WIDTH If two units are installed side by side, a dual installation kit may be required. Installations without a custom filler strip require a dual installation kit. If a dual installation kit is not specified, a 51 mm filler strip is recommended between the units. Dual installations without a filler strip can only be accomplished using two units with opposite hinges. Refer to the illustrations below. Dual installation kits are available through an authorized Sub-Zero dealer. SIDE VIEW DUAL OPENING WIDTH FRONT VIEW NOTE: 89 mm finished returns will be visible and should be finished to match cabinetry. The electrical supply must not be behind the appliance but in accessible cabinets either side. The electrical outlet must be positioned with the grounding prong to the right of the thinner blades. WARNING WARNING Electrical Supply Service Receptacle 220-240 V AC, 50/60 Hz 10 amp Do not locate multiple portable socket-outlets, power strip, or portable power supplies at the rear of the appliance. grounding-type (earthed) WARNING W Two 610 mm Models CAUTION The outlet must be checked by a qualified electrician to be sure it is wired with the correct polarity. Verify the outlet is properly grounded (earthed). If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. ELECTRICAL REQUIREMENTS TOP VIEW H Installation must comply with all applicable electrical codes and be properly grounded (earthed). 1219 mm Do not use an extension cord, two-prong adapter, or remove the power cord ground prong. Dual installation kit required. 19 mm 19 mm TYPICAL 89 mm FINISHED RETURN FINISHED RETURN W Electrical Shock Hazard TYPICAL 89 mm FILLER Plug power cord directly into a properly grounded (earthed) outlet. Do not defeat the grounding (earthing) nature of the plug. Do not use adapter or extension cord. Failure to follow these instructions could cause serious injury or death. W FRAMELESS CABINETRY OPENING DIMENSIONS 610 mm Model FRAMED CABINETRY W H 610 mm 876 mm See installation instructions WITHOUT FILLER STRIP Opposite hinges FILLER STRIP Same side hinges subzero.com 3

Site Preparation Preparation Uncrate the unit and inspect for damage. Remove and recycle packing materials. Do not discard the kickplate, anti-tip bracket, and hardware. Remove the kickplate by extracting the two mounting screws. Refer to the illustration below. Anti-Tip Bracket WARNING To prevent the unit from tipping forward, the anti-tip bracket must be installed. The anti-tip bracket should be attached to the wall behind the unit with the bracket flange located 6 mm above the top of the unit. Refer to the illustration below. Failure to properly position the anti-tip bracket will prevent proper engagement. 90 Door Stop The door stop pins provided with the unit limit the door swing to 90 . IMPORTANT NOTE: If a 90 door opening is desired, the pins must be installed prior to installing the unit into the opening. To install, open the door to approximately 80 . Insert one hinge pin into each hinge. Refer to the illustration below. Placement CAUTION Before moving the unit into position, secure the door closed and protect any finished flooring. WARNING When positioning the appliance, ensure the supply cord is not trapped or damaged. Use an appliance dolly to move the unit near the opening. DOOR STOP PIN ANTI-TIP BRACKET SCREW Plug the power cord into the grounded outlet and slide the unit into position. Verify the anti-tip bracket is properly engaged. 6 mm Kickplate removal 90 door stop Anti-tip bracket 4 English If the unit has been on its back or side, it must stand upright for a minimum of 24 hours before connecting power.

Installation Door Panel Alignment Stainless Steel Panel Custom Panel Stainless steel panels are available through an authorized Sub‑Zero dealer. A custom door panel and handle hardware must be installed. Minimum 3 mm reveals are required. A 16 mm minimum to 19 mm maximum thick panel is required. The panel cannot exceed the maximum panel weight indicated in the chart below. The depth of each model is 587 mm. Allow for panel thickness when planning the finished opening depth. LEVELING ANCHORING Once the unit is in position, rotate the front legs clockwise to raise and counterclockwise to lower. Rear height adjustment can be made from the front. Using a Phillips drive, turn clockwise to raise the unit or counterclockwise to lower. Use the lowest torque setting when using a power drill. Do not turn the leveling legs by hand. Refer to the illustration below. When the unit is properly leveled, door adjustments are less likely to be necessary. IMPORTANT NOTE: Level the unit to the floor, not the surrounding cabinetry. This could affect the operation of the unit, such as door closing. WARNING CAUTION If using a power drill to predrill holes or install screws, verify the drill chuck does not contact the units face frame. Adjust the depth of the unit to fit flush with the surrounding cabinetry. Allow for panel thickness. Once aligned, verify the door opens properly, then install screws in each bracket. Minimum 3 mm reveals are required. PANEL WEIGHT MAX 610 mm Model 10 kg WARNING To avoid a hazard due to instability of the appliance, it must be fixed in accordance with the instructions. Finish all sides of the custom panel. They will be visible when the door is open. A D-style handle is recommended. Locate the door handle near the edge of the panel opposite the hinge and centered top to bottom. Stainless steel tubular and pro handles are avail able through an authorized Sub-Zero dealer. To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor. Anchoring FRONT ADJUSTMENT REAR ADJUSTMENT Leveling subzero.com 5

Door Panel Installation Custom Panel Panel Installation TOE KICK CLEARANCE MAXIMUM DOOR OPENING DOOR PANEL INSTALLATION DOOR PANEL ADJUSTMENT The height of the toe kick area can extend beyond the typical toe kick height, provided it does not exceed the dimensions in the illustration below. As the panel width and/or depth increases, so does the potential for panel interference. Interference may be minimized by using the 90 door stop. Typical panel dimensions are based on an 876 mm finished height with 3 mm reveals. Placement of the template must be adjusted for panels exceeding the typical dimensions. Close the door. Make any necessary adjustments to align the panel and reveals. Place the panel face down on a protected work surface. Position the template flush with the top and sides of the panel. Verify the correct side of the template is being used, then mark and drill holes. Refer to the illustration below. 876 mm Use a Torx drive to partially insert a #8 x 1/2" screw into the second hole from the top on each side of the panel. The screws should be approximately 4 mm proud of the panel and will support the weight of the panel during installation. DOOR OPEN MAXIMUM 115 TYPICAL PRODUCT HEIGHT DOOR OPEN 90 587 mm TO BACK OF UNIT DOOR PANEL HINGE DECORATIVE KICKPLATE CANNOT EXTEND BEYOND THIS POINT 51 mm TO 86 mm* FROM FLOOR DECORATIVE KICKPLATE HEIGHT 114 mm 10 mm 3 mm REVEAL 29 mm KICKPLATE ADJUSTMENT ADJACENT CABINETRY 89 mm *Not included. Dimension will vary as the product height increases or decreases from the typical product height. BACK OF PANEL LEFT SIDE DOOR PANEL RIGHT SIDE DOOR PANEL Door panel template English BRACKET SCREWS BRACKET SCREWS Maximum door opening (top view) TOP OF DOOR PANEL IN-AND-OUT CAM UP-AND-DOWN CAM TOP OF DOOR PANEL 6 For up-and-down and in-and-out adjustments, slightly loosen the bracket screws. Depending on the level of adjustment required, it may be helpful to loosen all of the bracket screws which will allow for maximum adjustment. Once the bracket screws are loosened, use a wrench to rotate the cams to make adjustments. After the adjustments have been made, tighten all bracket screws. Refer to the illustrations below. CAUTION As reveals between cabinetry and the unit decrease, severe finger pinching can occur while the door is closing. MAX DEPTH Toe kick clearance (side view) DOOR CLOSED 19 mm PANEL Align the support screws on the back of the panel with the slotted holes on both door mounting brackets. Refer to the illustration below. Opening the door slightly may help with alignment. Once the panel is supported by the screws, partially insert a #8 x 1/2" screw into the second hole from the bottom on each side of the panel, but do not tighten. For side-to-side adjustment, move the panel side to side, then install and tighten all mounting screws. Door panel mounting In-and-out adjustment Up-and-down adjustment

Installation Completion DOOR TRIM INSTALLATION KICKPLATE INSTALLATION After the door panel has been adjusted, install the decorative side trim to the door. To install, start at the top and align the trim with the front and rear flanges on the bracket, then snap into place by pushing the trim toward the back of the panel. Once the top is secure, continue the installation downward until the remaining trim is completely secure. Refer to the illustration below. The kickplate must be removable for service. The floor cannot interfere with removal. Finger-tighten the adjustment bracket nuts. Refer to the illustration below. Make in-and-out adjustments, then wrench-tighten the bracket nuts. Install the kickplate with the provided screws. SIDE TRIM INSTALLATION Install the decorative trim strip to the handle side of the unit. The side trim snaps over the brackets attached to the handle side of the unit. Refer to the illustration below. A decorative kickplate can be attached to the factoryinstalled kickplate. The three rows of vented louvers cannot be covered. To install a decorative kickplate, remove the paper backing from the magnets and attach the decorative kickplate to the magnets. The magnets allow the decorative kickplate to be removed if necessary. KICKPLATE ADJUSTMENT Door side trim Unit side trim WARNING Follow all city and state laws when storing, recycling, or discarding unused refrigerators and freezers. Kickplate adjustment MAGNET SCREW Kickplate installation Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries. subzero.com 7

SUB-ZERO, INC. P.O. BOX 44848 MADISON, WI 53744 USA 9042183 REV-A 10 / 2020 SUBZERO.COM 800.222.7820

Custom Panel A custom door panel and handle hardware must be installed. A 16 mm minimum to 19 mm maximum thick panel is required. The panel cannot exceed the maximum panel weight indicated in the chart below. The depth of each model is 587 mm. Allow for panel thickness when planning the finished opening depth. Minimum 3 mm reveals are required.

Related Documents:

Design Fundamentals* *Fashion and Textiles Food Technology Industrial Technology Multimedia Photography (Video and Digital Imaging)* Visual Arts *Subject is non ATAR. Designer: graphic designer, fashion designer, furniture designer, industrial designer, interior designer, jewellery designer, landscape designer, textile designer

for, it is a truism that the old wine is better than new wine, and, therefore, even as an irony, a metaphor which uses old wine negatively is hard to be accepted. Thus, C. H. Talbert suggests to interpret the new cloth and wine/the old garment and winskins in vv. 36-38 and the new wine/the old wine as referring to different things.

Wine Cellar Models: KUWS24RSBS KUWS24LSBS KUWS24RSSS KUWO24RSBX KUWO24LSBX Beverage Center Models: KBCS24RSBS KBCS24LSBS KBCS24RSSS KBCO24RSBX KBCO24LSBX Undercounter Refrigerator Models: KURS24RSBS KURS24LSBS KURS24RSSS KURO24RSBX KURO24LSBX KitchenAid Undercounter Refrigeration Suite. ii .

2-2. Wine Rack Wine rack detail may vary according to the model types. Each rack can hold 8 wine bottles and top rack holds 9 bottles. 2-3 Others Glass Holder-Hangs wine glasses. (LRV810TT) Wine Rack-Stores leftover wine (tilted). (LRV810TT, LRV650TT) Locking Device-Key is enclosed in the inside of the refrigerator.

UNDERCOUNTER TYPE DISHWASHER Kasap Tip Dik BuzdolaplarıA1 PRODUCT DESCRIPTION *The Professional Undercounter Type Dishwasher ,that provides high efficiency has been designed to be used in industrial kitchens. Product Code Dimensions (mm) Weight (kg) Packaging Dimensions (mm) EMP.500 590x700x820 67 725x650x970 A2 TECHNICAL INFORMATION

Wedding Invitation Designer - Social Media Promotional’ s Designer and Marketer -Flyer Designer Corporate Gift: Mug Corporate Event Invitation Card Designer Web Banner Designer -Magazine Cover Designer Slideshows & Promo Videos Creator -Poster Designer Data Entry Operator News

DESIGNER Line Comparison Chart 1.2 2 FEATURES DESIGNER EPIC 2 DESIGNER BRILLIANCE 80 DESIGNER TOPAZ 50 DESIGNER TOPAZ 40 DESIGNER JADE 35 Multi-Size Embroidery Fonts 8 5 2/1 1 Embroidery Unit Size Large Large Medium/Small Small Imperial Hoop 14¼”x10¼” (360x260mm) Included

Cost Transparency Storage Storage Average Cost The cost per storage Cost Transparency Storage Storage Average Cost per GB The cost per GB of storage Cost Transparency Storage Storage Devices Count The quantity of storage devices Cost Transparency Storage Storage Tier Designates the level of the storage, such as for a level of service. Apptio .